Search results for " High pressure liquid"

showing 10 items of 705 documents

Liquid Chromatographic Analysis of Amphetamine and Related Compounds in Urine Using Solid-Phase Extraction and 3,5-Dinitrobenzoyl Chloride for Deriva…

1997

A chromatographic method for the analysis of amphetamine and related compounds in urine using 3,5-dinitrobenzoyl chloride (3,5-DNB) as a labeling reagent is presented. This assay is based on the employment of solid-phase extraction (SPE) cartridges for sample cleanup and derivatization. Experimental conditions are optimized for the simultaneous derivatization of ephedrine, norephedrine, pseudoephedrine, beta-phenylethylamine, amphetamine, methamphetamine, and 3-phenylpropylamine. The derivatives formed are separated in a LiChrospher 1000 RP18 (125 x 4-mm i.d., 5-microns film thickness) analytical column using a water-acetonitrile gradient elution and detected at 254 nm. Derivatization in C1…

Detection limitAnalyteChromatographyAmphetaminesGeneral MedicinePseudoephedrineHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistryNitrobenzoatesReagentmedicineIndicators and ReagentsSolid phase extractionEphedrineDerivatizationChromatography High Pressure Liquidmedicine.drugJournal of Chromatographic Science
researchProduct

Green determination of eight water-soluble B vitamins in cosmetic products by liquid chromatography with ultraviolet detection.

2021

Abstract B vitamins are a group of compounds with beneficious properties for dermatologic care, and therefore they are included in the cosmetic formulations as high added-value ingredients. In this paper, an analytical method for the simultaneous determination of eight water-soluble B vitamins in cosmetic products is reported for the first time. This method is based on liquid chromatography with ultraviolet detection (LC-UV) analysis after simple water leaching of the analytes from the cosmetic matrix. No organic solvents are required, beyond the ethanol used in the chromatographic mobile phase. The proposed method has been successfully validated showing good linearity, limits of detection …

Detection limitAnalyteChromatographyChemistryClinical BiochemistryPharmaceutical ScienceReproducibility of ResultsWaterRepeatabilityCosmeticsmedicine.disease_causeAnalytical ChemistryMatrix (chemical analysis)B vitaminsWater solubleLeaching (chemistry)Drug DiscoveryVitamin B ComplexmedicineSolventsSpectroscopyUltravioletChromatography High Pressure LiquidChromatography LiquidJournal of pharmaceutical and biomedical analysis
researchProduct

High-performance liquid chromatographic determination of spironolactone and its major metabolite canrenone in urine using ultraviolet detection and c…

1994

A rapid and simple column liquid chromatographic method involving a column-switching system for the determination of spironolactone and its main metabolite canrenone in urine is described. Purification and concentration was performed using an Hypersil ODS-C18, 30 microns (20 x 2.1 mm I.D.) pre-column. The most polar urinary compounds were removed by washing the pre-column with water, and the analytes were subsequently switched to a LiChrospher RP C18, 5 microns (125 x 4 mm I.D.) analytical column and separated by means of an acetonitrile-water mobile-phase. Under the proposed conditions, the extraction efficiency was approximately 100% over the 0.5-10.0 micrograms/ml concentration range. Th…

Detection limitAnalyteChromatographyChemistryMetaboliteExtraction (chemistry)General ChemistryUrineSpironolactoneHigh-performance liquid chromatographychemistry.chemical_compoundCanrenonemedicineHumansIndicators and ReagentsSpectrophotometry UltravioletCanrenoneQuantitative analysis (chemistry)Chromatography High Pressure Liquidmedicine.drugJournal of chromatography. B, Biomedical applications
researchProduct

Protein mapping by two-dimensional high performance liquid chromatography.

2000

Current developments in drug discovery in the pharmaceutical industry require highly efficient analytical systems for protein mapping providing high resolution, robustness, sensitivity, reproducibility and a high throughput of samples. The potential of two-dimensional (2D) HPLC as a complementary method to 2D-gel electrophoresis is investigated, especially in view of speed and repeatability. The method will be applied for proteins of a molecular mass <20 000 which are not well resolved in 2D-gel electrophoresis. The 2D-HPLC system described in this work consisted of anion- or cation-exchange chromatography in the first dimension and reversed-phase chromatography in the second dimension. We …

Detection limitAnalyteChromatographyElutionChemistryOrganic ChemistryIon chromatographyAnalytical chemistryProteinsReproducibility of ResultsGeneral MedicineRepeatabilityReversed-phase chromatographyChromatography Ion ExchangeBiochemistryHigh-performance liquid chromatographyPeptide MappingSensitivity and SpecificityAnalytical ChemistryTwo-dimensional chromatographyChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Development of a fully automated sequential injection solid-phase extraction procedure coupled to liquid chromatography to determine free 2-hydroxy-4…

2010

Abstract 2-Hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid, commonly known as benzophenone-3 (BZ3) and benzophenone-4 (BZ4), respectively, are substances widely used as UV filters in cosmetic products in order to absorb UV radiation and protect human skin from direct exposure to the deleterious wavelengths of sunlight. As with other UV filters, there is evidence of their percutaneous absorption. This work describes an analytical method developed to determine trace levels of free BZ3 and BZ4 in human urine. The methodology is based on a solid-phase extraction (SPE) procedure for clean-up and pre-concentration, followed by the monitoring of the UV filters by…

Detection limitAnalyteChromatographymedicine.diagnostic_testChemistryElutionSolid Phase ExtractionExtraction (chemistry)TemperatureHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryBenzophenonesSpectrophotometryStandard additionmedicineHumansEnvironmental ChemistrySpectrophotometry UltravioletSolid phase extractionSelectivitySunscreening AgentsChromatography High Pressure LiquidSpectroscopyAnalytica Chimica Acta
researchProduct

Exploring hand-portable nano-liquid chromatography for in place water analysis: Determination of trimethylxanthines as a use case.

2020

Abstract Analytical performance and optimization of figures of merit of a portable nano liquid chromatograph (NanoLC) with UV detection at 255 nm have been established for in place analysis. Methylxanthines: caffeine, theophylline and theobromine were selected as target analytes. A fast lab method based on IT-SPME coupled on line with capillary liquid chromatograph (CapLC) with diode array detection (DAD) was employed for comparative studies. IT-SPME and solid phase extraction were coupled off-line to NanoLC for improving instrumental parameters, mainly detection capacity and selectivity. IT-SPME or SPE/portable NanoLC based methods were superior in terms of chromatographic resolution and o…

Detection limitAnalyteEnvironmental EngineeringChromatographyMaterials science010504 meteorology & atmospheric sciencesResolution (mass spectrometry)Capillary action010501 environmental sciences01 natural sciencesPollutionDiode arrayNano liquid chromatographyTheophyllineLimit of DetectionCaffeineEnvironmental ChemistryFigure of meritSolid phase extractionWaste Management and DisposalChromatography High Pressure LiquidSolid Phase MicroextractionWater Pollutants Chemical0105 earth and related environmental sciencesChromatography LiquidThe Science of the total environment
researchProduct

Bioanalysis of digoxin and its metabolites using direct serum injection combined with liquid chromatography and on-line immunochemical detection.

1994

Abstract An automated dual-column liquid chromatographic assay for digoxin is described. Serum samples are directly injected onto a restricted-access solid-phase extraction support. After liquid chromatographic (LC) separation on a C18 analytical column, antigenic analytes are detected by means of post-column immunochemical detection (ICD) using fluorescein-labelled antibodies against digoxigenin. The detection limit of this assay is 160 pg/ml (preconcentration of 1.0 ml serum). With the present method digoxin and three of its cross-reactive metabolites were determined in serum taken from patients which were orally administered a 1-mg dose of digoxin. The results obtained with LC—ICD were c…

Detection limitBioanalysisAnalyteDigoxinChromatographyDigoxinmedicine.diagnostic_testMetaboliteImmunochemistryFluoroimmunoassayGeneral ChemistryCross Reactionschemistry.chemical_compoundchemistryImmunoassaymedicineDigoxigeninHumansQuantitative analysis (chemistry)DigoxigeninBiomarkersChromatography High Pressure Liquidmedicine.drugJournal of chromatography. B, Biomedical applications
researchProduct

Urine polyamines determination using dansyl chloride derivatization in solid-phase extraction cartridges and HPLC

1999

The derivatization of biogenic amines such as putrescine, cadaverine, spermidine and spermine with dansyl chloride in solid phase extraction cartridges is described. Different types of filling materials were tested in order to have the highest retention of the different analytes. The best results were obtained by using C18 cartridges. The optimal conditions were: amine solution buffered at pH 12, 2 mM dansyl chloride (acetone-bicarbonate solution 20 mM (pH 9-9.5), 2 + 3 v/v) as reagent concentration, room temperature and 30 min reaction time. The developed procedure was applied to the determination of these polyamines in urine samples from healthy controls and cancer patients using HPLC wit…

Detection limitCadaverineChromatographyBiogenic PolyaminesDansyl chlorideBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistryNeoplasmsReagentBiomarkers TumorElectrochemistryPutrescineHumansEnvironmental ChemistrySolid phase extractionDerivatizationChromatography High Pressure LiquidSpectroscopyThe Analyst
researchProduct

Determination of carbamate residues in fruits and vegetables by matrix solid-phase dispersion and liquid chromatography-mass spectrometry.

2000

Abstract Thirteen carbamates were analysed in orange, grape, onion and tomatoes by matrix solid-phase dispersion (MSPD) followed by liquid chromatography–mass spectrometry (LC–MS). Electrospray (ES) and atmospheric pressure chemical ionisation (APCI) were compared and both gave similar results in terms of sensitivity and structural information because at 20 V fragmentor voltages the fragmentation is minimal. The efficiency of different solid-phases (C18, C8, cyano, amine and phenyl) for the MSPD was compared. Mean recoveries using C8 varied from 64 to 106% with relative standard deviations of 5–15% in the concentration range of 0.01–10 mg kg−1. Matrix constituents did not interfere signific…

Detection limitChemical ionizationInsecticidesChromatographyChemistryOrganic ChemistryPesticide ResiduesAtmospheric-pressure chemical ionizationGeneral MedicineMass spectrometryBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityMass SpectrometryAnalytical ChemistryLiquid chromatography–mass spectrometryFruitVegetablesmedia_common.cataloged_instanceSolid phase extractionCarbamatesEuropean unionChromatography High Pressure Liquidmedia_commonJournal of chromatography. A
researchProduct

Quantification of nortriptyline in plasma by HPLC and fluorescence detection

2009

Abstract A simple, sensitive and specific high-performance liquid chromatography method has been developed for the determination of nortriptyline (NT) in plasma samples. The assay involved derivatization with 9H-fluoren-9-ylmethyl chloroformate (Fmoc-Cl) and isocratic reversed-phase (C 18 ) chromatography with fluorescence detection. The developed method required only 100 μl of plasma sample, deproteinized and derivatized in one step. Calibration curves were lineal over the concentration range of 5–5000 ng/ml. The derivatization reaction was performed at room temperature in 20 min and the obtained NT derivative was stable for at least 48 h at room temperature. The within-day and between-day…

Detection limitChromatographyCalibration curveClinical BiochemistryNortriptylineCell BiologyGeneral MedicineDerivativeChloroformateBiochemistryHigh-performance liquid chromatographyFluorescenceAntidepressive AgentsRatsAnalytical Chemistrychemistry.chemical_compoundchemistryLimit of DetectionmedicineAnimalsHumansNortriptylineDerivatizationChromatography High Pressure Liquidmedicine.drugJournal of Chromatography B
researchProduct