Search results for " Medical imaging"
showing 10 items of 1067 documents
Comparison of Flow Measurement by 4D Flow Magnetic Resonance Imaging and by Particles Image Velocimetry on Phantom of Abdominal Aortic Aneurysm
2016
International audience; Predicting the rupture of Aortic Aneurysms is a complex problem that interests, from several decades, many researchers. The works on this issue are very complex, involving both the study of mechanical behavior of the artery as the flow of blood. The Magnetic Resonance Imaging (MRI) technique allows to obtain anatomic information of the arteries, than the flow inside thereof. The goal of this study is an inter comparison betweenflow data from MRI and those obtained by Particle Image Velocimetry (PIV). An experimental device simulating hemodynamic circulation is used. Initially in order to validate the device, the flow in a cylindrical glass tube is measured by these t…
Radial electron fluence around ion tracks as a new physical parameter for the detection threshold of PADC using Geant4-DNA toolkit
2018
International audience; The detection threshold of poly(allyl dyglycol carbonate), PADC, for C ions is determined as 55 eV/nm in stopping power, which is significantly higher than that for proton and He ions. The stopping power is not a universal parameter for expressing the detection threshold of PADC. A new physical parameter of Radial Electron Fluence around Ion Tracks, REFIT, is proposed to describe the detection threshold of PADC. It is defined as the number density of electrons passing through the surface of a cylinder of a certain radius that is co-axial with the trajectory. Furthermore, preliminary calculations are presently being performed using the Monte Carlo simulation code of G…
Evaluation of the areal material distribution of paper from its optical transmission image
2011
International audience; The goal of this study was to evaluate the areal mass distribution (defined as the X-ray transmission image) of paper from its optical transmission image. A Bayesian inversion framework was used in the related deconvolution process so as to combine indirect optical information with a priori knowledge about the type of paper imaged. The a priori knowledge was expressed in the form of an empirical Besov space prior distribution constructed in a computationally effective way using the wavelet transform. The estimation process took the form of a large-scale optimization problem, which was in turn solved using the gradient descent method of Barzilai and Borwein. It was de…
Left-Ventricle Segmentation of SPECT Images of Rats
2015
Single-photon emission computed tomography (SPECT) imaging of the heart is helpful to quantify the left-ventricular ejection fraction and study myocardial perfusion scans. However, these evaluations require a 3-D segmentation of the left-ventricular wall on each phase of the cardiac cycle. This paper presents a fast and interactive graph cut method for 3-D segmentation of the left ventricle (LV) of rats in SPECT images. The method is carried out in three steps. First, 3-D sampling of the LV cavity is made in a spherical-cylindrical coordinate system. Then, a graph-cut-based energy minimization procedure provides delineation of the myocardium centerline surface. From there, it is possible to…
Redshifted Cherenkov Radiation for in vivo Imaging: Coupling Cherenkov Radiation Energy Transfer to multiple Förster Resonance Energy Transfers
2017
AbstractCherenkov Radiation (CR), this blue glow seen in nuclear reactors, is an optical light originating from energetic β-emitter radionuclides. CR emitter 90Y triggers a cascade of energy transfers in the presence of a mixed population of fluorophores (which each other match their respective absorption and emission maxima): Cherenkov Radiation Energy Transfer (CRET) first, followed by multiple Förster Resonance Energy transfers (FRET): CRET ratios were calculated to give a rough estimate of the transfer efficiency. While CR is blue-weighted (300–500 nm), such cascades of Energy Transfers allowed to get a) fluorescence emission up to 710 nm, which is beyond the main CR window and within t…
Optimal recovery of a radiating source with multiple frequencies along one line
2020
We study an inverse problem where an unknown radiating source is observed with collimated detectors along a single line and the medium has a known attenuation. The research is motivated by applications in SPECT and beam hardening. If measurements are carried out with frequencies ranging in an open set, we show that the source density is uniquely determined by these measurements up to averaging over levelsets of the integrated attenuation. This leads to a generalized Laplace transform. We also discuss some numerical approaches and demonstrate the results with several examples.
Algorithms for the Automated Analysis of Age-Related Macular Degeneration Biomarkers on Optical Coherence Tomography: A Systematic Review
2017
PURPOSE To assess the quality of optical coherence tomography (OCT) grading algorithms for retinal biomarkers of age-related macular degeneration (AMD). METHODS Following a systematic review of the literature data on detection and quantification of AMD retinal biomarkers by available algorithms were extracted and descriptively synthesized. Algorithm quality was assessed using a modified version of the Quality Assessment of Diagnostic Accuracy Studies 2 checklist with a focus on accuracy against established reference standards and risk of bias. RESULTS Thirty five studies reporting computer-aided diagnosis (CAD) tools for qualitative analysis or algorithms for quantitative analysis were iden…
Multicenter Consistency Assessment of Valvular Flow Quantification With Automated Valve Tracking in 4D Flow CMR
2021
OBJECTIVES This study determined: 1) the interobserver agreement; 2) valvular flow variation; and 3) which variables independently predicted the variation of valvular flow quantification from 4-dimensional (4D) flow cardiac magnetic resonance (CMR) with automated retrospective valve tracking at multiple sites. BACKGROUND Automated retrospective valve tracking in 4D flow CMR allows consistent assessment of valvular flow through all intracardiac valves. However, due to the variance of CMR scanners and protocols, it remains uncertain if the published consistency holds for other clinical centers. METHODS Seven sites each retrospectively or prospectively selected 20 subjects who underwent whole …
Energy conversion efficiency in betavoltaic cells based on the diamond Schottky diode with a thin drift layer
2020
The HPHT diamond Schottky diode was assembled as a Metal/Intrinsic/p-doped structure betavoltaic cell (BC) with a very thin (1 μm) drift layer and tested under 5–30 keV electron beam irradiation using a scanning electron microscope (SEM). The effect of the β-radiation energy and the backscattering of electrons on the energy conversion was studied. From the results obtained, it is shown that, the efficiency of the investigated BC increases from 1.01 to 3.75% with the decrease of β-particle energy from 30 to 5 keV due to an increase of the electron beam absorption in a thin drift layer. Maximum efficiency is achieved when the electron beam energy is close to the average β-decay energy of 3H. …
Influence of K on the transport of Cs-137 in soil–plant root and root-leaf systems in sugar beet
2015
The main aim of this study was to determine the influence of K-40 activity in the soil on the transport of Cs-137 from the soil to plants and the impact of its activity on the internal transport of Cs-137 between anatomical parts of the sugar beet. The activity concentration of Cs-137 in the soil was bigger than that in the beet. The highest activity concentration of K-40 was observed in beet leaves, while its content in roots and the soil were comparable.