Search results for " Quality"
showing 10 items of 3133 documents
Cardiovascular imaging in the diagnosis and monitoring of cardiotoxicity: cardiovascular magnetic resonance and nuclear cardiology
2016
Chemotherapy-induced cardiotoxicity (CTX) is a determining factor for the quality of life and mortality of patients administered potentially cardiotoxic drugs and in long-term cancer survivors. Therefore, prevention and early detection of CTX are highly desirable, as is the exploration of alternative therapeutic strategies and/or the proposal of potentially cardioprotective treatments. In recent years, cardiovascular imaging has acquired a pivotal role in this setting. Although echocardiography remains the diagnostic method most used to monitor cancer patients, the need for more reliable, reproducible and accurate detection of early chemotherapy-induced CTX has encouraged the introduction o…
Blastocyst formation is similar in obese and normal weight women: a morphokinetic study
2021
Abstract STUDY QUESTION Does the embryo cleavage pattern and rate of blastocyst formation differ between normal weight and obese women undergoing IVF? SUMMARY ANSWER Embryo morphokinetic development, final blastocyst formation rate and blastocyst morphology do not differ between obese and normal weight women. WHAT IS KNOWN ALREADY Female obesity has been related to impaired IVF outcomes. Although the mechanisms responsible for this detrimental effect are thought to include impaired oocyte and embryo quality and reduced endometrial receptivity, they are yet to be confirmed. Embryo quality has been commonly assessed using static morphological criteria. Only three studies have analysed the pro…
Ambient carbon monoxide and daily mortality:a global time-series study in 337 cities
2021
Background Epidemiological evidence on short-term association between ambient carbon monoxide (CO) and mortality is inconclusive and limited to single cities, regions, or countries. Generalisation of results from previous studies is hindered by potential publication bias and different modelling approaches. We therefore assessed the association between short-term exposure to ambient CO and daily mortality in a multicity, multicountry setting. Methods We collected daily data on air pollution, meteorology, and total mortality from 337 cities in 18 countries or regions, covering various periods from 1979 to 2016. All included cities had at least 2 years of both CO and mortality data. We estimat…
Multimodality 3-dimensional volumetric ultrasound in obstetrics and gynecology with an emphasis in HDlive technique.
2013
HDlive (high-definition live or real-time US), a new ultrasound software, combines a movable virtual adjustable light source in a software that calculates the proportion of light reflecting through surface structures, depending on light direction. The light source can be manually positioned to illuminate the desired area of interest. The ultrasound technician can control light intensity to create shadows that enhance image quality. HDlive is an innovation that will render even more realistic images of fetal anatomy and of gynecologic lesions. The full potential of this new technology is yet to be determined and deserves scientific evaluation.
Sleep disturbances in tension-type headache and migraine
2017
Current research into the pathogenesis of tension-type headache (TTH) and migraine is focused on altered nociceptive pain processing. Among the potential factors that influence sensitization mechanisms, emotional stress, depression, or sleep disorders all have an essential role: they increase the excitability of nociceptive firing and trigger hyperalgesic responses. Sleep disturbances and headache disorders share common brain structures and pathogenic mechanisms and TTH, migraine, and sleep disturbances often occur together; for example, 50% of individuals who have either TTH or migraine have insomnia. Moreover, insomnia and poor sleep quality have been associated with a higher frequency an…
Niederfeld MR-Arthrographie der Schulter: Erste Ergebnisse mit einem offenen 0,2 T MR-System
1998
PURPOSE To assess the practicability and image quality of doing MR arthrography of the shoulder using a 0.2T system. PATIENTS AND METHOD 60 patients (24 with chronic instability, 36 with impingement syndrome) were examined in an open 0.2T MR apparatus (Magnetom Open, Siemens). After the intra-articular injections of 15-20 ml of a 2 mmol Gd-DTPA solution, coronary STIR, T1-weighted, sagittal and axial T2*-weighted FLASH 2D sequences were performed. 21 patients subsequently underwent surgery. RESULTS Image quality of the T1- and T2*-weighted FLASH 2D sequences was regarded as good or adequate and movement artifacts were minor or moderate. STIR sequences were statistically significantly worse …
Evaluation of the methodological quality of articles on autologous breast reconstruction
2018
Abstract Background Breast cancer remains the most common cancer among women worldwide. Autologous breast reconstruction may contribute toward restoring body image and improving quality of life after mastectomy. This systematic literature review describes differences in the quality and type of studies investigating autologous breast reconstruction techniques over time. Methods MEDLINE was searched for articles related to the surgical techniques, namely, TRAM, LADO, DIEP, and SGAP/IGAP, for the periods 1970 to 2007 and 2008 to 2010. The quality and type of studies were compared across the two time periods. Full-texts were evaluated according to prespecified quality criteria. Results The MEDL…
Optical quality of intraocular lenses after several years in the human eye
2013
The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…
Influence of the tear film on optical quality of the eye
1997
The optical quality of the tear film of the eye was tested by measuring the retinal image before and after the break-up time (BUT). An objective method was used based on the evaluation of the retinal image of a point test projected onto the fovea. The loss of an entire tear film would result in a decrease in the optical quality because of corneal irregularities and the formation of an irregular tear lens after the BUT. Our results confirm the expected loss both of non-contact lens wearers and contact lens wearers. Also, the fact that the optical deterioration found after the BUT is greater for contact lens wearers confirms that soft contact lens wear produces a disruption of the tears.
Bilateral Ultrathin Descemet’s Stripping Automated Endothelial Keratoplasty vs. Bilateral Penetrating Keratoplasty in Fuchs’ Dystrophy: Corneal Highe…
2021
Background and Objectives: The objective of this paper is to compare the visual outcomes and quality of life (QoL) after bilateral ultrathin Descemet’s stripping automated endothelial keratoplasty (UT-DSAEK) with bilateral penetrating keratoplasty (PK) for Fuchs’ endothelial dystrophy (FED). Materials and Methods: Retrospective comparative cohort study, including 11 patients with FED who underwent bilateral PK and 13 patients with FED who underwent bilateral UT-DSAEK. All patients were already pseudophakic or had undergone a combined cataract procedure. The main outcomes were corrected distance visual acuity (CDVA) corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and quali…