Search results for " atom"

showing 10 items of 1526 documents

Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

2011

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsLow emittancePhysics and Astronomy (miscellaneous)Nuclear engineering[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]FOS: Physical sciencesbeam transport01 natural sciencesBeam characteristicslaw.inventionNuclear physicslaw0103 physical sciencesddc:530lcsh:Nuclear and particle physics. Atomic energy. RadioactivityBeam handling010306 general physicsAccelerator Test FacilityPhysicsFocus (computing)Research Groups and Centres\Physics\Low Temperature Physics010308 nuclear & particles physicsFaculty of Science\PhysicsBeam commissioningFísicaParticle acceleratorSurfaces and Interfaces29.27.Eg 29.27.Fh 29.20.dbAccelerators and Storage RingsStorage rings and collidersCOLLIDERSTechnology for normal conducting higher energy linear accelerators [9]BeamlineTest beamlcsh:QC770-798Physics - Accelerator PhysicsBeam (structure)
researchProduct

Polarization-Dependent Disappearance of a Resonance Signal -- Indication for Optical Pumping in a Storage Ring?

2021

We report on laser spectroscopic measurements on Li$^+$ ions in the experimental storage ring ESR at the GSI Helmholtz Centre for Heavy Ion Research. Driving the $2s\,^3\!{S}_1\;(F=\frac{3}{2}) \,\leftrightarrow\,2p\,^3\!P_2\;(F=\frac{5}{2}) \leftrightarrow 2s\,^3\!{S}_1\;(F=\frac{5}{2})$ $\Lambda$-transition in $^7$Li$^+$ with two superimposed laser beams it was found that the use of circularly polarized light leads to a disappearance of the resonance structure in the fluorescence signal. This can be explained by optical pumping into a dark state of polarized ions. We present a detailed theoretical analysis of this process that supports the interpretation of optical pumping and demonstrate…

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsPhysics and Astronomy (miscellaneous)Atomic Physics (physics.atom-ph)FOS: Physical sciences53001 natural sciencesIonlaw.inventionPhysics - Atomic PhysicsOptical pumpinglaw0103 physical scienceslcsh:Nuclear and particle physics. Atomic energy. Radioactivityddc:530010306 general physicsCircular polarizationPhysics010308 nuclear & particles physicsSurfaces and InterfacesLaserPolarization (waves)FluorescenceDark statelcsh:QC770-798Physics - Accelerator PhysicsAtomic physicsStorage ring
researchProduct

Direct Measurement of Focusing Fields in Active Plasma Lenses

2018

Physical review accelerators and beams 21(12), 122801 (2018). doi:10.1103/PhysRevAccelBeams.21.122801

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsPhysics and Astronomy (miscellaneous)Field (physics)FOS: Physical sciences01 natural sciences530law.inventionOpticslaw0103 physical sciencesddc:530Thermal emittancelcsh:Nuclear and particle physics. Atomic energy. Radioactivity010306 general physicsphysics.acc-phPhysics010308 nuclear & particles physicsbusiness.industrySurfaces and InterfacesPlasmaNuclear & Particles PhysicsLens (optics)Physics::Space PhysicsPhysical SciencesCathode raylcsh:QC770-798Physics::Accelerator PhysicsPhysics - Accelerator PhysicsBeam emittancebusinessCharged particle beamBeam (structure)
researchProduct

Simulations and measurements of beam loss patterns at the CERN Large Hadron Collider

2014

The CERN Large Hadron Collider (LHC) is designed to collide proton beams of unprecedented energy, in order to extend the frontiers of high-energy particle physics. During the first very successful running period in 2010-2013, the LHC was routinely storing protons at 3.5-4 TeV with a total beam energy of up to 146 MJ, and even higher stored energies are foreseen in the future. This puts extraordinary demands on the control of beam losses. An uncontrolled loss of even a tiny fraction of the beam could cause a superconducting magnet to undergo a transition into a normal-conducting state, or in the worst case cause material damage. Hence a multistage collimation system has been installed in ord…

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsPhysics and Astronomy (miscellaneous)Monte Carlo methodFOS: Physical sciencesSuperconducting magnetTracking (particle physics)law.inventionNuclear physicslawlcsh:Nuclear and particle physics. Atomic energy. RadioactivityNuclear Experiment (nucl-ex)Large Hadron Collider (France and Switzerland)Nuclear ExperimentPhysicsLarge Hadron ColliderColliders (Nuclear physics)Particle acceleratorCollimatorSurfaces and InterfacesAccelerators and Storage RingsOrders of magnitude (time)lcsh:QC770-798Physics::Accelerator PhysicsPhysics - Accelerator PhysicsBeam (structure)
researchProduct

Highly efficient isotope separation and ion implantation of  163Ho for the ECHo project

2019

Abstract The effective electron neutrino mass measurement in the framework of the ECHo experiment requires radiochemically pure 163 Ho, which is ion implanted into detector absorbers. To meet the project specifications in efficiency and purity, the entire process chain of ionization, isotope separation , and implantation of 163Ho was optimized. A new two-step resonant laser ionization scheme was established at the 30 kV magnetic mass separator RISIKO. For ionization and separation, an average efficiency of 69 ( 5 )  stat(4)sys% was achieved using intra-cavity frequency doubled Ti:sapphire lasers. The implantation of undesired 166 m Ho, which is present in trace amounts in the initial  163Ho…

Accelerator Physics (physics.acc-ph)PhysicsNuclear and High Energy PhysicsAtomic Physics (physics.atom-ph)Orders of magnitude (temperature)DetectorAnalytical chemistryFOS: Physical sciencesLaser01 natural sciencesPhysics - Atomic Physics010305 fluids & plasmasIsotope separationlaw.inventionIonIon implantationlawIonization0103 physical sciencesSapphirePhysics - Accelerator Physics010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Characterization and Tuning of Ultra High Gradient Permanent Magnet Quadrupoles

2009

The application of quadrupole devices with high field gradients and small apertures requires precise control over higher order multipole field components. We present a new scheme for performance control and tuning, which allows the illumination of most of the quadrupole device aperture because of the reduction of higher order field components. Consequently, the size of the aperture can be minimized to match the beam size achieving field gradients of up to $500\text{ }\text{ }\mathrm{T}\text{ }{\mathrm{m}}^{\ensuremath{-}1}$ at good imaging quality. The characterization method based on a Hall probe measurement and a Fourier analysis was confirmed using the high quality electron beam at the M…

Accelerator Physics (physics.acc-ph)electron beamNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorscompactmagneticlensPhysics and Astronomy (miscellaneous)Field (physics)AperturemultipoleFOS: Physical sciencespermanenthalbachx-felNuclear magnetic resonancetuningquadrupolelcsh:Nuclear and particle physics. Atomic energy. RadioactivityQuadrupole magnetMicrotronPhysicsOrder (ring theory)Surfaces and InterfacesInstrumentation and Detectors (physics.ins-det)beam focusingComputational physicsMagnetQuadrupolelcsh:QC770-798Physics::Accelerator PhysicsPhysics - Accelerator PhysicsMultipole expansion
researchProduct

A comparative study on sample preparation procedures for supplementary foods by ICP-OES: Green chemistry considerations

2015

An inductively coupled plasma optical emission (ICP-OES) method was developed for the simultaneous determination of major, minor and trace elements in food. Preliminary studies focused on selecting suitable operational conditions in order to provide the highest sensitivity and to maximize the number of analytes to be determined without spectral or matrix interference. Ruthenium and rhenium were evaluated as internal standards and samples were analyzed at different dilution levels. Furthermore, a comparative study was carried out by using three sample digestion methods, microwave-assisted digestion with HNO3/H2O2, dry ashing and dry ashing with Mg(NO3)2/MgO as an ashing aid. Adequate precisi…

Accuracy and precisionAnalyteChromatographyChemistryGeneral Chemical EngineeringGeneral EngineeringAnalytical chemistryAnalytical ChemistryDilutionCertified reference materialsAshingInductively coupled plasma atomic emission spectroscopySample preparationInductively coupled plasmaAnalytical Methods
researchProduct

Determination of Cd, Cu, Pb and Zn content of infant formulas by differential pulse anodic stripping voltammetry (DPASV).

1994

The differential pulse anodic stripping voltammetry (DPASV) method described is based on the one reported by Hasse et al., but adapted to normal laboratory conditions. The values obtained in the estimation of the analytical parameters (linearity, detection and quantification limits, precision and accuracy) show that in the conditions described the method is sensitive enough, reliable and useful for determining these elements in infant formulas. A comparison between DPASV and atomic absorption spectroscopy (AAS) methods in the conditions described here shows that the former is less sensitive but that they are similar in precision. The cadmium, copper, lead and zinc contents of different type…

Accuracy and precisionAnalytical chemistrychemistry.chemical_elementZincNitric Acidlaw.inventionlawSpectrophotometryElectrochemistrymedicineHumansPolarographyCadmiummedicine.diagnostic_testSpectrophotometry AtomicInfantCopperAnodic stripping voltammetrychemistryMetalsSpainIndicators and ReagentsInfant FoodAtomic absorption spectroscopyPolarographyFood Science
researchProduct

Estimation of Arsenic Bioaccessibility in Edible Seaweed by an in Vitro Digestion Method

2003

The aim of this study was to examine the bioaccessibility (maximum soluble concentration in gastrointestinal medium) of total (AsT) and inorganic (AsI) arsenic contents and the effect on them of cooking edible seaweed, a food of great interest because of its high As content. An in vitro gastrointestinal digestion (pepsin, pH 2, and pancreatin−bile extract, pH 7) was applied to obtain the mineral soluble fraction of three seaweeds (Hizikia fusiforme, Porphyra sp., and Enteromorpha sp.). AsT was determined by dry-ashing flow injection hydride generation atomic absorption spectrometry. AsI was determined by acid digestion, solvent extraction, and flow injection hydride generation atomic absorp…

Acid digestionHot Temperaturechemistry.chemical_elementFraction (chemistry)In Vitro TechniquesArseniclaw.inventionPepsinlawBileFood scienceArsenicbiologyChemistrySpectrophotometry AtomicGeneral ChemistryHydrogen-Ion ConcentrationSeaweedIn vitro digestionbiology.organism_classificationPepsin APorphyraEdible seaweedSolubilityPancreatinbiology.proteinDigestionGeneral Agricultural and Biological SciencesAtomic absorption spectroscopyJournal of Agricultural and Food Chemistry
researchProduct

Measuring single small molecule binding via rupture forces of a split aptamer.

2011

The rupture force of a split (bipartite) aptamer that forms binding pockets for adenosine monophosphate (AMP) was measured by atomic force spectroscopy. Changes in the rupture force were observed in the presence of AMP, while this effect was absent when mutant aptamers or inosine were used. Thus, changes in the rupture force were a direct consequence of specific binding of AMP to the split aptamer. The split aptamer concept allowed the detection of nonlabeled AMP and enabled us to determine the dissociation constant on a single-molecule level.

Adenosine monophosphateChemistryAptamerForce spectroscopyGeneral ChemistryPlasma protein bindingAptamers NucleotideMicroscopy Atomic ForceBiochemistryCatalysisAdenosine MonophosphateDissociation constantCrystallographychemistry.chemical_compoundColloid and Surface ChemistrymedicineDirect consequenceSmall molecule bindingInosinemedicine.drugProtein BindingJournal of the American Chemical Society
researchProduct