Search results for " bet"

showing 10 items of 1744 documents

Performance of short-chain alcohols versus acetonitrile in the surfactant-mediated reversed-phase liquid chromatographic separation of β-blockers

2010

Organic solvents are traditionally added to micellar mobile phases to achieve adequate retention times and peak profiles, in a chromatographic mode which has been called micellar liquid chromatography (MLC). The organic solvent content is limited to preserve the formation of micelles. However, at increasing organic solvent contents, the transition to a situation where micelles do not exist is gradual. Also, there is no reason to neglect the potentiality of mobile phases containing only surfactant monomers instead of micelles (high submicellar chromatography, HSC). This is demonstrated here for the analysis of β-blockers. The performance of four organic solvents (methanol, ethanol, 1-propano…

Chromatography Reverse-PhaseAcetonitrilesChromatographyElutionAdrenergic beta-AntagonistsOrganic ChemistrySodium Dodecyl SulfateGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyMicelleAnalytical ChemistrySurface-Active Agentschemistry.chemical_compoundModels ChemicalchemistryPulmonary surfactantMicellar liquid chromatographyAlcoholsData Interpretation StatisticalMethanolAcetonitrileAlgorithmsMicellesJournal of Chromatography A
researchProduct

Approaches to characterise chromatographic column performance based on global parameters accounting for peak broadening and skewness.

2009

Peak broadening and skewness are fundamental parameters in chromatography, since they affect the resolution capability of a chromatographic column. A common practice to characterise chromatographic columns is to estimate the efficiency and asymmetry factor for the peaks of one or more solutes eluted at selected experimental conditions. This has the drawback that the extra-column contributions to the peak variance and skewness make the peak shape parameters depend on the retention time. We propose and discuss here the use of several approaches that allow the estimation of global parameters (non-dependent on the retention time) to describe the column performance. The global parameters arise f…

Chromatography Reverse-PhaseChromatographyAcetonitrilesResolution (mass spectrometry)ChemistryElutionOrganic ChemistryAdrenergic beta-AntagonistsLinear modelNormal DistributionGeneral MedicineReversed-phase chromatographyBiochemistryColumn (database)Standard deviationAnalytical ChemistryNormal distributionModels ChemicalSkewnessBenzene DerivativesLinear ModelsDiureticsJournal of chromatography. A
researchProduct

Implementation of gradients of organic solvent in micellar liquid chromatography using DryLab®: Separation of basic compounds in urine samples

2014

In micellar liquid chromatography (MLC), chromatographic peaks are more evenly distributed compared to conventional reversed-phase liquid chromatography (RPLC). This is the reason that most procedures are implemented using isocratic elution. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, decreasing the analysis time. Also, it benefits the determination of moderately to low polar compounds in physiological fluids performing direct injection: an initial micellar eluent with a low organic solvent content, or a pure micellar (without surfactant) solution, will provide better protection of the column against the proteins i…

Chromatography Reverse-PhaseChromatographyChemistryElutionChemical polarityAdrenergic beta-AntagonistsOrganic ChemistryAnalytical chemistryGeneral MedicineBiochemistryAnalytical ChemistrySurface-Active Agentschemistry.chemical_compound1-PropanolColumn chromatographyPulmonary surfactantMicellar liquid chromatographyCritical micelle concentrationSolventsHumansIndicators and ReagentsAnalytical proceduresMicellesSoftwareJournal of Chromatography A
researchProduct

Gaining insight in the behaviour of imidazolium-based ionic liquids as additives in reversed-phase liquid chromatography for the analysis of basic co…

2015

In reversed-phase liquid chromatography in the absence of additives, cationic basic compounds give rise to broad and asymmetrical peaks as a result of ionic interactions with residual free silanols on silica-based stationary phases. Ionic liquids (ILs), added to the mobile phase, have been suggested as alternatives to amines to block the activity of silanols. However, the dual character of ILs should be considered: both cation and anion may be adsorbed on the stationary phase, thereby creating a double asymmetrical layer positively or negatively charged, depending on the relative adsorption of both ions. In this work, a study of the performance of six imidazolium-based ILs (the chlorides an…

Chromatography Reverse-PhaseChromatographyTetrafluoroborateOrganic ChemistryCationic polymerizationImidazolesIonic bondingIonic LiquidsGeneral MedicineReversed-phase chromatographyBiochemistryAdrenergic beta-1 Receptor AntagonistsAnalytical Chemistrychemistry.chemical_compoundAdsorptionchemistryChloridesPhase (matter)Ionic liquidBoratesOrganic chemistryAminesTriethylamineChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Performance of micellar mobile phases in reversed-phase chromatography for the analysis of pharmaceuticals containing beta-blockers and other antihyp…

1996

A rapid and simple reversed-phase micellar liquid chromatographic procedure for the simultaneous determination of the beta-blockers atenolol, metoprolol and oxprenolol, the diuretics amiloride, bendroflumethiazide, chlorthalidone and hydrochlorothiazide and the vasodilator hydralazine in pharmaceuticals, is proposed. An interpretive optimization procedure, which uses the chromatographic data for only five mobile phases, was applied to select a suitable micellar mobile phase. A comparative study was also made of the performance of micellar and aqueous-organic mobile phases in the analysis of pharmaceuticals that combine beta-blockers and diuretics. The determination of all the drugs could be…

ChromatographyAdrenergic beta-AntagonistsReversed-phase chromatographyAtenololHydralazineBiochemistryHigh-performance liquid chromatographyDosage formAnalytical Chemistrychemistry.chemical_compoundHydrochlorothiazidechemistryOxprenololElectrochemistrymedicineSolventsEnvironmental ChemistryBendroflumethiazideSodium dodecyl sulfateDiureticsSpectroscopyAntihypertensive AgentsChromatography High Pressure LiquidMicellesmedicine.drugThe Analyst
researchProduct

Quantitative structure-retention and retention-activity relationships of beta-blocking agents by micellar liquid chromatography.

2001

Abstract Sixteen β-blocking agents (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol and timolol) showing a large range of hydrophobicity (octanol–water partition coefficients, log P between −0.026 and 2.81) were subjected to micellar liquid chromatography with sodium dodecyl sulfate as micelle forming agent, and n-propanol as organic modifier. The correlation between log P and the retention factor extrapolated to a mobile phase free of micelles and organic modifier was investigated. The use of an interpolated retention factor or the retention factor for specific individual exp…

ChromatographyChemistryOrganic ChemistryAdrenergic beta-AntagonistsQuantitative Structure-Activity RelationshipGeneral MedicineBiochemistryMicelleAcebutololMicellar electrokinetic chromatographyAnalytical ChemistryPartition coefficientchemistry.chemical_compoundMicellar liquid chromatographyOxprenololmedicineAlprenololSodium dodecyl sulfateMicellescirculatory and respiratory physiologymedicine.drugChromatography LiquidJournal of chromatography. A
researchProduct

Improvement of peak shape and separation performance of beta-blockers in conventional reversed-phase columns using solvent modifiers.

2003

A comparative study of peak shape, elution behavior, and resolution of 16 beta-blockers (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol, and timolol) chromatographed with hybrid mobile phases of triethylamine (TEA)-acetonitrile and sodium dodecyl sulfate (SDS)-propanol is performed using conventional reversed-phase columns and isocratic elution. Both solvent modifiers (TEA and SDS) prevent the interaction of the basic drugs with the alkyl-bonded phase. However, the protection mechanisms of silanols on the packing are different. Whereas TEA associates with the silanol sites (b…

ChromatographyElutionAdrenergic beta-AntagonistsAnalytical chemistryGeneral MedicineReversed-phase chromatographyHigh-performance liquid chromatographyAnalytical ChemistrySolventchemistry.chemical_compoundSilanolchemistryOxprenololmedicineSolventsSpectrophotometry UltravioletSodium dodecyl sulfateTriethylamineChromatography High Pressure Liquidmedicine.drugJournal of chromatographic science
researchProduct

Levels in the interpretive optimisation of selectivity in high-performance liquid chromatography: a magical mystery tour.

2006

Interpretive approaches for selectivity optimisation, which are those supported by retention models, are able to exploit efficiently the capabilities of the chromatographic system. The resolution of a mixture is usually faced in a first trial by looking for a unique experimental condition, able to resolve all compounds in the sample. If this is not possible, the problem can be outlined with less ambitious aims, focusing on only some compounds. In an extreme case, a single analyte can be individually optimised. Current strategies that give answer to the different goals pursued in the analysis, which are classified as total, partial and specific, are reviewed. Optimisation oriented to deconvo…

ChromatographyExploitChemistryComputer aidOrganic ChemistryAdrenergic beta-AntagonistsReproducibility of ResultsSample (statistics)General MedicineResolution (logic)Models TheoreticalBiochemistryHydrocarbons AromaticAnalytical ChemistryMultivariate AnalysisGradient elutionDeconvolutionAmino AcidsChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Interpretive optimisation of organic solvent content and flow-rate in the separation of β-blockers with a Chromolith RP-18e column

2009

The chromatographic performance of a Chromolith RP-18e column was comprehensively examined for a group of basic drugs (beta-blockers), eluted with isocratic ACN-water mixtures at increasing flow-rate up to 6 mL/min. As the flow-rate increases at fixed mobile phase composition, peak distribution (selectivity) is maintained, but the relative peak widths increase. This reduces the resolution below satisfactory values for closely eluting compounds. With the monolithic column, flow-rate becomes thus an important factor to be optimised, in addition to the mobile phase composition. Since, theoretically, retention factors (k) are independent of the flow-rate, the classical quadratic model relating …

ChromatographyMonolithic HPLC columnResolution (mass spectrometry)ChemistryElutionAdrenergic beta-AntagonistsAnalytical chemistryFiltration and SeparationReversed-phase chromatographyHigh-performance liquid chromatographyAnalytical ChemistryVolumetric flow rateSolventModels ChemicalSolventsOrganic ChemicalsSelectivityChromatography High Pressure LiquidJournal of Separation Science
researchProduct

Paradoxical effect of increased diastolic Ca(2+) release and decreased sinoatrial node activity in a mouse model of catecholaminergic polymorphic ven…

2012

Background— Catecholaminergic polymorphic ventricular tachycardia is characterized by stress-triggered syncope and sudden death. Patients with catecholaminergic polymorphic ventricular tachycardia manifest sinoatrial node (SAN) dysfunction, the mechanisms of which remain unexplored. Methods and Results— We investigated SAN [Ca 2+ ] i handling in mice carrying the catecholaminergic polymorphic ventricular tachycardia–linked mutation of ryanodine receptor (RyR2 R4496C ) and their wild-type (WT) littermates. In vivo telemetric recordings showed impaired SAN automaticity in RyR2 R4496C mice after isoproterenol injection, analogous to what was observed in catecholaminergic polymorphic ventricul…

ChronotropicTachycardiaMalePatch-Clamp TechniquesAction Potentials030204 cardiovascular system & hematologyVentricular tachycardiaMice0302 clinical medicineSinoatrial NodeCatecholaminergic0303 health sciencesRyanodine receptorAdrenergic beta-AgonistsMiddle AgedSarcoplasmic Reticulummedicine.anatomical_structurecardiovascular systemCardiologyFemalemedicine.symptomCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyIn Vitro TechniquesCatecholaminergic polymorphic ventricular tachycardiaSudden deathArticle03 medical and health sciencesPhysiology (medical)Internal medicinemedicineAnimalsHumansCalcium SignalingExercise030304 developmental biologyAgedbusiness.industrySinoatrial nodeIsoproterenolRyanodine Receptor Calcium Release Channelmedicine.diseaseMice Mutant StrainsMice Inbred C57BLDisease Models AnimalEndocrinologyMutationTachycardia VentricularCalciumbusinessCirculation
researchProduct