Search results for " image."
showing 10 items of 3908 documents
Multidimensional Optical Sensing and Imaging Systems (MOSIS): From Macro to Micro Scales
2017
Multidimensional optical imaging systems for information processing and visualization technologies have numerous applications in fields such as manufacturing, medical sciences, entertainment, robotics, surveillance, and defense. Among different three-dimensional (3-D) imaging methods, integral imaging is a promising multiperspective sensing and display technique. Compared with other 3-D imaging techniques, integral imaging can capture a scene using an incoherent light source and generate real 3-D images for observation without any special viewing devices. This review paper describes passive multidimensional imaging systems combined with different integral imaging configurations. One example…
Automatic detection of lung nodules in CT datasets based on stable 3D mass–spring models
2012
We propose a computer-aided detection (CAD) system which can detect small-sized (from 3 mm) pulmonary nodules in spiral CT scans. A pulmonary nodule is a small lesion in the lungs, round-shaped (parenchymal nodule) or worm-shaped (juxtapleural nodule). Both kinds of lesions have a radio-density greater than lung parenchyma, thus appearing white on the images. Lung nodules might indicate a lung cancer and their early stage detection arguably improves the patient survival rate. CT is considered to be the most accurate imaging modality for nodule detection. However, the large amount of data per examination makes the full analysis difficult, leading to omission of nodules by the radiologist. We…
Graph-matching based CTA.
2009
Separating bone, calcification, and vessels in computer tomography angiography (CTA) allows for a detailed diagnosis of vessel stenosis. This paper presents a new, graph-based technique that solves this difficult problem with high accuracy. The approach requires one native data set and one that is contrast enhanced. On each data set, an attributed level-graph is derived and both graphs are matched by dynamic programming to differentiate between bone, on one hand side, and vessel/calcification on the other hand side. Lumen and calcified regions are then separated by a profile technique. Evaluation is based on data from vessels of pelvis and lower extremities of elderly patients. Due to subst…
Diffuse reflectance and fluorescence multispectral imaging system for assessment of skin
2014
The diffuse reflectance multispectral imaging technique has been used for distant mapping of in vivo skin chromophores (hemoglobin and melanin). The fluorescence multispectral imaging is not so common for skin applications due to complicity of data acquisition and processing, but could provide additional information about skin fluorophores. Both techniques are compatible, and could be combined into a multimodal solution. The multispectral imaging system Nuance based on liquid crystal tunable filters was adapted for diffuse reflectance and fluorescence spectral imaging of in vivo skin. Uniform illumination was achieved by LED ring light. Combination of four LEDs (warm white, 770 nm, 830 nm a…
Skin haemoglobin mapping: comparison of multi-spectral imaging and selective R-G-B analysis
2010
The multi-spectral imaging technique has been used for distant mapping of in-vivo skin haemoglobin. Besides, potential of selective R-G-B analysis of skin images has been studied under bi-chromatic (532 nm and 635 nm) laser illumination.
Influence of the tear film on optical quality of the eye
1997
The optical quality of the tear film of the eye was tested by measuring the retinal image before and after the break-up time (BUT). An objective method was used based on the evaluation of the retinal image of a point test projected onto the fovea. The loss of an entire tear film would result in a decrease in the optical quality because of corneal irregularities and the formation of an irregular tear lens after the BUT. Our results confirm the expected loss both of non-contact lens wearers and contact lens wearers. Also, the fact that the optical deterioration found after the BUT is greater for contact lens wearers confirms that soft contact lens wear produces a disruption of the tears.
3×3 Technique for RGB Snapshot Mapping of Skin Chromophores
2015
Three monochromatic spectral images have been extracted from a single RGB image data set at simultaneous illumination of skin by 473nm, 532nm and 609nm spectral lines. They were further transformed into distribution maps of three skin chromophores - melanin, oxy-hemoglobin and deoxy-hemoglobin, related to pigmented and vascular skin malformations. Performance and clinical potential of the proposed 3×3 technique is discussed.
Skin chromophore mapping by modified video-microscope
2013
Possibilities to map skin chromophores using a modified low-cost digital video-microscope is discussed. The device comprises CMOS digital imaging sensor, four-colour LED illumination system and image acquisition optics. The main goal is to obtain a set of spectral images of the skin area of interest for further conversion into maps of the main skin chromophores
Skin chromphore mapping by means of a modified video-microscope for skin malformation diagnosis
2013
Many spectral imaging devices are commercially available and used to detect certain skin pathology; however an alternative cost-efficient device can provide an advanced spectral analisys of skin. Multispectral device for diagnosis of pigmented skin lesions was developed and tested. Possibilities to map skin chromophores using a modified low-cost digital video-microscope is discussed. It was adapted for an advanced skin microscopy and used for detailed spectral analysis of skin. The device comprises CMOS digital imaging sensor, four-colour LED illumination system and image acquisition optics. The main goal is to obtain a set of spectral images of the skin area of interest for further convers…
Bonnes pratiques de radiothérapie guidée par l’image
2015
Image-guided radiotherapy (IGRT) aims to take into account the anatomical variations occurring during the course of radiotherapy, by direct or indirect visualization of the target volume followed by a corrective action. The movements of the target, or at least the set-up errors are corrected by moving the treatment table, corresponding to the simplest and most validated IGRT modality in a standard practice. The deformations of the target volume and organs at risk are however much more common, and unfortunately much more complicated to consider, requiring multiple planning before or during the treatment, corresponding to the adaptive radiotherapy strategies. The planning target volume must b…