Search results for " implantation."
showing 10 items of 677 documents
Short implants (8mm) versus longer implants (≥8mm) with lateral sinus floor augmentation in posterior atrophic maxilla: A meta-analysis of RCT`s in h…
2019
Background One of the greatest challenges that dentists face today is to rehabilitate severe atrophied alveolar ridges in partially and completely edentulous patients with implants. Despite the high survival rate of implants placed next to sinus elevation, this technique presents complications that can be avoided by placing short implants, an option that also presents high survival rates. For this reason, the aim of this study is to compare the survival rate, marginal bone loss and complications associated with short implants (<8 mm) versus longer implants (≥8mm) placed with lateral sinus floor elevation in posterior atrophic maxillae. Material and Methods A literature search was conducted …
Predilation, sizing and post-dilation scoring in patients undergoing everolimus-eluting bioresorbable scaffold implantation for prediction of cardiac…
2017
Aims: The aim of the study was to develop a scoring model to evaluate the quality of bioresorbable vascular scaffold (BVS) implantation and determine the model's usefulness in predicting adverse cardiac events. Methods and results: The implantation technique and clinical outcomes of 1,736 lesions treated with BVS were analysed using the GHOST-EU registry. Predilation, scaffold sizing, and post-dilation (PSP) were scored according to the hazard model derived from the weight of these variables. The primary end-point was a one-year device-oriented composite endpoint (DoCE) composed of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation. Def…
In vivo and in vitro degradation of a novel bioactive guided tissue regeneration membrane
2006
The aim of this study was to assess degradation of a novel bioactive guided tissue regeneration (GTR) membrane and to quantify the concurrent tissue responses. Pieces of membrane composed of poly-l-lactide, poly-d,l-lactide, trimethylenecarbonate and polyglycolide were dipped into an N-methyl-2-pyrroline (NMP) solution and implanted in the mandibles of 10 sheep. The animals were sacrificed at 6-104 weeks. Parallel in vitro degradation was analysed by measuring the inherent viscosity, water absorption and remaining mass. One of the 2 in vitro sets of membranes was prehandled with NMP. At 6-26 weeks in vivo, the gradually more degraded implants were surrounded by a fibrous network. At 52 and …
Immediate implants placed in fresh sockets associated to periapical infectious processes: a systematic review
2013
Objetives: The development of treated implant surfaces, added to the increase of the aesthetic requirements by the patients has led to a change in the treatment protocols as well as the development of techniques such as the onefase implants and the immediate prosthetic loading. One of the usual contraindications of the implant treatment is the presence of periapical disease associated to the tooth to be replaced. The aim of this paper is to review the published literature on immediate implant placement in extraction sockets of teeth with periapical pathology, considering the level of scientific evidence, and following the principles of medicine and evidence-based Dentistry. Material and Met…
What are the benefits of a minimally invasive approach in frail octogenarian patients undergoing aortic valve replacement?
2016
Not available
Aortic valve and vascular calcium score in pre-TAVI CT: correlation with early post-procedural complications
2023
Abstract Purpose The aim of our study was to evaluate the prevalence of early complications after Transcatheter Aortic Valve Implantation (TAVI) and their correlation with the Calcium Score (CS) of the aortic valve, aorta and ilio-femoral arteries derived from pre-procedural computed tomography (CT). Materials and methods We retrospectively reviewed 226 patients (100 males, mean age 79.4 ± 6.7 years) undergoing 64-slice CT for pre-TAVI evaluation from January 2018 to April 2021. The population was divided into CS quartiles. Results Overall, 173 patients underwent TAVI procedure, of whom 61% presented paravalvular leak after the procedure, 28% presented bleeding or vascular complications, 25…
Augmented Reality in minimally invasive otologic surgery and transmodiolar cochlear implantation
2021
Optimal exposure is necessary for minimally invasive otologic surgery. Augmented reality allows to enrich the real environment by adding data without replacing it by a virtual environment and to view this information on a single screen by combining the vision of the operating field and the imaging. This technique is very little described in otology in the literature. This project aims to develop augmented reality solutions for otological surgeries and transmodiolar implantation. To prepare this augmented reality project, we studied the visualization of the middle ear by a virtual endoscope based on preoperative high resolution CT-scans. Then, we worked on the application of augmented realit…
Scaffold vascularization in vivo driven by primary human osteoblasts in concert with host inflammatory cells.
2011
Successful cell-based tissue engineering requires a rapid and thorough vascularization in order to ensure long-term implant survival and tissue integration. The vascularization of a scaffold is a complex process, and is modulated by the presence of transplanted cells, exogenous and endogenous signaling proteins, and the host tissue reaction, among other influencing factors. This paper presents evidence for the significance of pre-seeded osteoblasts for the in vivo vascularization of a biodegradable scaffold. Human osteoblasts, cultured on silk fibroin micronets in vitro, migrated throughout the interconnected pores of the scaffold and produced extensive bone matrix. When these constructs we…
Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.
2008
We reviewed recently published studies that analyzed the visual and optical quality in eyes with different spherical and aspheric intraocular lenses (IOLs). Recent studies focused on visual quality metrics, such as visual acuity and contrast sensitivity, under photopic and mesopic lighting conditions and optical metrics, such as wavefront aberrations, especially spherical aberration. The results in this review were used in an attempt to understand whether there is a visual and/or optical benefit of implanting aspheric IOLs over implanting spherical IOLs.
Biological and technical complications of tilted implants in comparison with straight implants supporting fixed dental prostheses. A systematic revie…
2018
OBJECTIVES To evaluate the implant failure, marginal bone loss (MBL), and other biological or technical complications of restorations supported by tilted and straight implants after at least 3 years in function. METHODS Electronic and manual searches were performed in MEDLINE, Embase, Web of Science, and OpenGrey to identify clinical studies published up to December 2017. After duplicate study selection and data extraction, the risk of bias was assessed with the ROBINS-I tool. Random-effects meta-analyses of relative risks (RRs) or mean differences (MD) and their 95% confidence intervals (CIs) were performed, followed by subgroup/sensitivity analyses and application of the GRADE approach. R…