Search results for " stimulation"

showing 10 items of 1644 documents

Different muscarine receptors mediate the prejunctional inhibition of [3H]-noradrenaline release in rat or guinea-pig iris and the contraction of the…

1989

To investigate the muscarine receptor type mediating inhibition of [3H]-noradrenaline release from the isolated rat and guinea-pig iris we have determined the potency of antimuscarinic drugs to antagonize the methacholine-induced inhibition of [3H]-noradrenaline overflow evoked by field stimulation (3 Hz, 2 min). The prejunctional apparent affinities were compared with those obtained for postjunctional muscarine receptors mediating the methacholine-induced contraction of the isolated rabbit iris sphincter muscle. Prejunctional apparent affinity constants of pirenzepine (6.67), himbacine (8.51), methoctramine (7.92), 4-diphenylacetoxy-N-methylpiperidine methiodide (4-DAMP, 8.00), hexahydro-d…

medicine.medical_specialtyContraction (grammar)Iris sphincter muscleIrisIn Vitro TechniquesBiologyGuinea pigNorepinephrinechemistry.chemical_compoundPiperidinesInternal medicineMuscarinic acetylcholine receptormedicineAnimalsMethacholine CompoundsNeurotransmitterReceptorPharmacologyMuscarineMuscle SmoothRats Inbred StrainsGeneral MedicineReceptors MuscarinicElectric StimulationRatsKineticsmedicine.anatomical_structureEndocrinologychemistrySphincterRabbitsMuscle ContractionNaunyn-Schmiedebergs Archives of Pharmacology
researchProduct

Proceedings of the Eighth Annual Deep Brain Stimulation Think Tank: Advances in Optogenetics, Ethical Issues Affecting DBS Research, Neuromodulatory …

2021

We estimate that 208,000 deep brain stimulation (DBS) devices have been implanted to address neurological and neuropsychiatric disorders worldwide. DBS Think Tank presenters pooled data and determined that DBS expanded in its scope and has been applied to multiple brain disorders in an effort to modulate neural circuitry. The DBS Think Tank was founded in 2012 providing a space where clinicians, engineers, researchers from industry and academia discuss current and emerging DBS technologies and logistical and ethical issues facing the field. The emphasis is on cutting edge research and collaboration aimed to advance the DBS field. The Eighth Annual DBS Think Tank was held virtually on Septem…

medicine.medical_specialtyDeep brain stimulationCoronavirus disease 2019 (COVID-19)medicine.medical_treatmentDBSNeurosciences. Biological psychiatry. NeuropsychiatryBioengineeringOptogeneticsneuroethicsBehavioral NeurosciencemedicinePsychologyMedical physicsPooled dataadaptive DBSnovel hardwareoptogeneticsNeurostimulationBiological PsychiatryDepression (differential diagnoses)Assistive TechnologyneuroimagingEthical issuesDepressionRehabilitationNeurosciencesDBS (deep brain stimulation)Experimental PsychologyBrain DisordersPsychiatry and Mental healthNeuropsychology and Physiological PsychologyMental HealthNeurologyPerspectiveNeurologicalCognitive SciencesNeuroethicsPsychologyNeuroscienceRC321-571
researchProduct

Letter: Risk Factors for Wire Fracture or Tethering in Deep Brain Stimulation: A 15-Year Experience

2021

medicine.medical_specialtyDeep brain stimulationTetheringbusiness.industrymedicine.medical_treatmentDeep Brain StimulationMEDLINEElectrodes ImplantedPhysical medicine and rehabilitationText miningRisk FactorsFracture (geology)medicineHumansSurgeryNeurology (clinical)businessBone Wires
researchProduct

A transcranial magnetic stimulation study evaluating methylprednisolone treatment in multiple sclerosis

2002

Objective To investigate the efficacy of two different high doses of intravenous methylprednisolone (IVMP) during Multiple Sclerosis (MS) relapses. Background Transcranial Magnetic Stimulation (TMS) is the most sensitive neurophysiological ascertainment to quantify motor disability, to follow the recovery from an MS relapse, and to detect the response to treatment. Design and method Twenty-four clinically definite relapsing - remitting MS patients presenting a relapse were randomly assigned to a treatment for 5 days with IVMP 1 or 2 g/day. The response to treatment of each patient was evaluated through Expanded Disability Status Scale (EDSS), Medical Research Council (MRC) score, and TMS by…

medicine.medical_specialtyExpanded Disability Status Scalemedicine.diagnostic_testbusiness.industryMultiple sclerosismedicine.medical_treatmentMagnetic resonance imagingGeneral Medicinemedicine.diseaselaw.inventionSurgeryTranscranial magnetic stimulationNeurologyRandomized controlled trialMethylprednisolonelawAnesthesiamedicineSilent periodNeurology (clinical)Evoked potentialbusinessmedicine.drugActa Neurologica Scandinavica
researchProduct

Design and fabrication of an ultra-flexible electrode system for invasive continuous monitoring during surgery

2009

This paper introduces the development, design and characterization of a tube with electrodes for stimulation and recording. This tube can be used as an operative monitoring system for thyroid surgery. In such surgeries damaging of the neural tissue can result in permanently malfunction. Continuous nerve monitoring can reduce significantly this risk.

medicine.medical_specialtyFabricationComputer sciencefungiNeural stimulationContinuous monitoringElectrodemedicinefood and beveragesTube (fluid conveyance)Monitoring systemSurgery
researchProduct

Effectiveness of tDCS to Improve Recognition and Reduce False Memories in Older Adults

2020

Background. False memories tend to increase in healthy and pathological aging, and their reduction could be useful in improving cognitive functioning. The objective was to use an active-placebo method to verify whether the application of tDCS in improving true recognition and reducing false memories in healthy older people. Method. Participants were 29 healthy older adults (65-78 years old) assigned to active or placebo group; active group received anodal stimulation at 2mA for 20 min over F7. An experimental task was used to estimate true and false recognition. The procedure took place in two sessions on two consecutive days. Results. A mixed ANOVA of true recognition showed a significant …

medicine.medical_specialtyFalse recognitionTranscranial direct-current stimulationbusiness.industrymedicine.medical_treatmentMedicineapplied_psychologyAudiologybusiness
researchProduct

Five-fold Gastrointestinal Electrical Stimulation With Electromyography-based Activity Analysis: Towards Multilocular Theranostic Intestinal Implants

2019

Background/aims Motility disorders are common and may affect the entire gastrointestinal (GI) tract but current treatment is limited. Multilocular sensing of GI electrical activity and variable electrical stimulation (ES) is a promising option. The aim of our study is to investigate the effects of adjustable ES on poststimulatory spike activities in 5 GI segments. Methods Six acute porcine experiments were performed with direct ES by 4 ES parameter sets (30 seconds, 25 mA, 500 microseconds or 1000 microseconds, 30 Hz or 130 Hz) applied through subserosal electrodes in the stomach, duodenum, ileum, jejunum, and colon. Multi-channel electromyography of baseline and post-stimulatory GI electri…

medicine.medical_specialtyGastrointestinal tractmedicine.diagnostic_testElectromyographybusiness.industryStomachGastroenterologyMotilityStimulationIleumElectromyographyGastroenterologyJejunummedicine.anatomical_structureGastrointestinal tractInternal medicinemedicineDuodenumElectric stimulationOriginal ArticleNeurology (clinical)businessJournal of Neurogastroenterology and Motility
researchProduct

ERPs to pitch changes: a result of reduced responses to standard tones in rabbits.

1996

EVENT-RELATED potentials (ERPs) were recorded in rabbits when pitch deviant tones occurred in a series of standard tones (oddball situation). In control recordings, the deviant tones were presented without the standard tones (deviant-alone situation). In the oddball situation, significant difference ERPs (deviant ERPs - standard ERPs) could be found in the hippocampal and cerebellar recordings but not in the visual cortex. All the ERPs to the deviant stimuli observed in the oddball situation were also present in the deviant-alone situation. The difference ERPs were therefore based on reduced responses to the standards. The results are discussed in the context of a mismatch negativity (MMN) …

medicine.medical_specialtyGeneral NeuroscienceSignificant differenceMismatch negativityContext (language use)CognitionAudiologyHippocampusElectric StimulationPitch DiscriminationElectrophysiologyCerebellar CortexVisual cortexmedicine.anatomical_structureAcoustic StimulationmedicineEvoked Potentials AuditoryAnimalsRabbitsPsychologyNeuroscienceVisual CortexNeuroreport
researchProduct

gamma-Aminobutyric acid and cholinergic transmission in the guinea-pig ileum.

1983

1. The effects of GABA on release of acetylcholine and on contractility of the smooth muscle were studied in the myenteric plexus-longitudinal muscle preparation of the guinea pig. Acetylcholine was determined as radiolabelled transmitter from strips preloaded with 3H-choline. 2. GABA (1–300 μM) caused an increase in resting tension of smooth muscle as well as an increase in release of acetylcholine that was considerably reduced by tetrodotoxin. The facilitation by GABA of acetylcholine release exhibited a marked tachyphylaxis. The increase in muscle tension was clearly related to the increase in acetylcholine release. Muscimol (0.1–10 μM) also enhanced the release of acetylcholine. The eff…

medicine.medical_specialtyGuinea PigsIn Vitro TechniquesBicucullineTritiumSynaptic Transmissiongamma-Aminobutyric acidchemistry.chemical_compoundIleumInternal medicineMuscle tensionMuscarinic acetylcholine receptormedicineAnimalsPicrotoxingamma-Aminobutyric AcidPharmacologyMuscimolMuscle SmoothGeneral MedicineBicucullineAcetylcholineElectric StimulationEndocrinologynervous systemchemistryMuscimolCholinergicAcetylcholinemedicine.drugPicrotoxinMuscle ContractionNaunyn-Schmiedeberg's archives of pharmacology
researchProduct

Characterization of prejunctional muscarinic autoreceptors in the guinea-pig trachea

1991

1. The effects of ten muscarinic antagonists on electrically evoked [3H]-acetylcholine release and muscle contraction were compared in an epithelium-free preparation of the guinea-pig trachea that had been preincubated with [3H]-choline. 2. The M3-selective antagonists UH-AH 37, 4-diphenyl-acetoxy-N-piperidine methobromide and para-fluorohexahydrosiladiphenidol were more potent in reducing the contractile response than in facilitating the evoked [3H]-acetylcholine release. Hexahydrosiladiphenidol did not discriminate between pre- and postjunctional effects. The rank order of the postjunctional potencies of the ten antagonists as well as the postjunctional pA2 values obtained for hexahydrosi…

medicine.medical_specialtyGuinea PigsIn Vitro TechniquesBiologyCholinechemistry.chemical_compoundInternal medicineMuscarinic acetylcholine receptormedicineMethoctramineAnimalsReceptorPharmacologyParasympatholyticsMuscarinic acetylcholine receptor M3Muscle SmoothMuscarinic acetylcholine receptor M2Receptors MuscarinicAcetylcholineElectric StimulationTracheaEndocrinologychemistryAutoreceptormedicine.symptomAcetylcholineMuscle ContractionResearch Articlemedicine.drugMuscle contractionBritish Journal of Pharmacology
researchProduct