Search results for "Kinetic"

showing 10 items of 3064 documents

NMR Study of the (Z)-Phenylhydrazones of 5-Alkyl- and 5-Aryl-3-benzoyl-1,2,4-oxadiazoles: Support for the Interpretation of Kinetic Results on the Re…

2005

An analysis of the 1H, 13C, and 15N NMR substituent chemical shifts (SCSs) of the title compounds in CDCl3 solution has been carried out by using the SCSs of other classes of compounds (arenes, methyl esters or amides), Hammett substituent constants or kinetic data. The results obtained provide information concerning the ground-state electronic distribution of the compounds examined. The results relevant to the carbon and nitrogen atoms of the 1,2,4-oxadiazole ring can be considered of special interest, as the effects of the substit- Introduction For several years our research group has been involved in the use of NMR spectroscopic data (1H, 13C, 15N, and 17O) to obtain information about th…

chemistry.chemical_classificationArylChemical shiftOrganic ChemistrySubstituentNuclear magnetic resonance spectroscopyKinetic energyRing (chemistry)Medicinal chemistrychemistry.chemical_compoundchemistryOrganic chemistry124-oxadiazoles NMR investigation Hammett substituent constantsPhysical and Theoretical ChemistryAlkylEuropean Journal of Organic Chemistry
researchProduct

Die oxydation von polyepoxiden mit molekularem sauerstoff

1966

Polypropylenoxid, Polybutylen-1-oxid und Polystyroloxid wurden dargestellt und mit Hilfe von Losungsmitteln in verschiedene taktische Fraktionen getrennt. Diese Fraktionen und Polyathylenoxide mit verschiedenem Molekulargewicht wurden in Substanz autoxydiert und die fluchtigen Reaktionsprodukte gaschromatographisch identifiziert. Die Autoxydation dieser Polymeren in Losung wurde durch Messung der Sauerstoffaufnahme verfolgt. Die Bruttoaktivierungsenergien der taktischen Fraktionen der Polymeren sind groser als die der ataktischen Fraktionen. Die Kinetik der Autoxydation des Polybutylen-1-oxides wurde aufgeklart. Polypropyleneoxide, polybutene-1-oxide, and polystyreneoxide were prepared and …

chemistry.chemical_classificationAutoxidationchemistryTacticityKineticsPolymer chemistryPolymerDie Makromolekulare Chemie
researchProduct

3'-Arylazido-beta-alanyl-2-azido ATP, a cross-linking photoaffinity label for F1ATPases.

1989

Abstract The synthesis of the 3′-arylazido-2-azido ATP derivative 3′-O-{3-[N-(4-azido-2-nitrophenyl)-amino]propionyl}2-azido-adenosine 5′-triphosphate (2,3′-DiN3ATP) is described. The bifunc­ tional photoreactive ATP analog is characterized spectroscopically. Photoaffinity labeling of F, ATPase from Micrococcus luteus by this analog results in the inactivation of the enzyme and in the formation of higher molecular weight cross-links,

chemistry.chemical_classificationAzidesPhotoaffinity labelingbiologyLightStereochemistryAffinity Labelsbiology.organism_classificationGeneral Biochemistry Genetics and Molecular BiologyMicrococcuschemistry.chemical_compoundKineticsProton-Translocating ATPasesEnzymeAdenosine TriphosphatechemistryIndicators and ReagentsBifunctionalBeta (finance)Micrococcus luteusDerivative (chemistry)Zeitschrift fur Naturforschung. C, Journal of biosciences
researchProduct

Proteolytic cleavage of soybean Bowman-Birk inhibitor monitored by means of high-performance capillary electrophoresis. Implications for the mechanis…

1996

The hydrolysis of the soybean Bowman-Birk inhibitor in the presence of catalytic amounts of bovine trypsin and the formation of the non-covalent enzyme-inhibitor complex with an equimolar amount of enzyme are monitored by means of high-performance capillary electrophoresis (HPCE). The inhibitor is cleaved in the trypsin-reactive and more slowly in the chymotrypsin-reactive subdomain. HPCE proves itself as the only reliable analytical tool to monitor these reactions in clear contrast to classical electrophoretic, chromatographic and enzymatic methods. The most efficient separation of the intact and the two active site cleaved forms of the inhibitor was achieved in borate buffer at pH 10.0. T…

chemistry.chemical_classificationBinding SitesChromatographybiologyChemistryHydrolysisMolecular Sequence DataBiophysicsElectrophoresis CapillaryActive siteCleavage (embryo)BiochemistryCatalysisProtein Structure TertiaryKineticsElectrophoresisHydrolysisReaction rate constantEnzymeCapillary electrophoresisBiochemistryEnzyme inhibitorbiology.proteinAmino Acid SequenceTrypsin Inhibitor Bowman-Birk SoybeanJournal of Biochemical and Biophysical Methods
researchProduct

Biophysical approaches for the study of metal-protein interactions

2019

Protein-protein interactions play important roles for a variety of cell functions, often involving metal ions; in fact, metal-ion binding mediates and regulates the activity of a wide range of biomolecules. Enlightening all of the specific features of metal-protein and metal-mediated protein-protein interactions can be a very challenging task; a detailed knowledge of the thermodynamic and spectroscopic parameters and the structural changes of the protein is normally required. For this purpose, many experimental techniques are employed, embracing all fields of Analytical and Bioinorganic Chemistry. In addition, the use of peptide models, reproducing the primary sequence of the metal-binding …

chemistry.chemical_classificationBiophysical methodsBinding Sites010405 organic chemistryChemistryBiomoleculeMetal-protein interactionsStructural and kinetic toolsProteinsComputational biologyAnalytical techniques010402 general chemistry01 natural sciencesBiochemistryCell function0104 chemical sciencesProtein–protein interactionInorganic ChemistryKineticsMetalsPeptidesPrimary sequenceProtein BindingJournal of Inorganic Biochemistry
researchProduct

2003

Resting cells of the yeast Rhodosporidium toruloides (UOFS Y-0471) were immobilised in calcium alginate beads for the enantioselective kinetic resolution of racemic-1,2-epoxyoctane. The initial activity exhibited by immobilised cells was almost 50% lower than that of the free counterpart but was extremely stable when compared to the free cells. The concentration of the immobilised biomass had no effect on apparent enzyme activity but did lead to a decrease in single cell activity. An increase in both the alginate and CaCl2 concentrations used for bead preparation led to a decrease in enzyme stability. An increase in the alginate concentration led to an increase in bead diameter. The stoichi…

chemistry.chemical_classificationCalcium alginateChromatographybiologyKineticsRhodosporidium toruloideschemistry.chemical_elementBioengineeringGeneral MedicineCalciumbiology.organism_classificationApplied Microbiology and BiotechnologyEnzyme assayYeastKinetic resolutionchemistry.chemical_compoundEnzymechemistryBiochemistrybiology.proteinBiotechnologyBiotechnology Letters
researchProduct

On the applicability of [18F]FBPA to predict L-BPA concentration after amino acid preloading in HuH-7 liver tumor model and the implication for liver…

2017

Abstract Introduction In recent years extra-corporal application of boron neutron capture therapy (BNCT) was evaluated for liver primary tumors or liver metastases. A prerequisite for such a high-risk procedure is proof of preferential delivery and high uptake of a 10 B-pharmaceutical in liver malignancies. In this work we evaluated in a preclinical tumor model if [ 18 F]FBPA tissue distribution measured with PET is able to predict the tissue distribution of [ 10 B]L-BPA. Methods Tumor bearing mice (hepatocellular carcinoma cell line, HuH-7) were either subject of a [ 18 F]FBPA-PET scan with subsequent measurement of radioactivity content in extracted organs using a gamma counter or injecte…

chemistry.chemical_classificationCancer ResearchBiodistributionPathologymedicine.medical_specialtyLiver tumorChemistryChemical structuremedicine.disease030218 nuclear medicine & medical imagingAmino acid03 medical and health sciences0302 clinical medicinemedicine.anatomical_structurePharmacokinetics030220 oncology & carcinogenesisHepatocellular carcinomamedicineCancer researchMolecular MedicineRadiology Nuclear Medicine and imagingPancreasGamma counterNuclear Medicine and Biology
researchProduct

Life-time studies with capillary electrochromatography columns operated under different conditions.

2000

A test system has been established to permit the monitoring of the life-time performance of several reversed- phase capillary electrochromatography (CEC) columns. The retention factors, k(cec), peak symmetry coefficients, lambda(sym), and column efficiencies, N, of three neutral n-alkylbenzene analytes, namely ethyl-, n-butyl- and n-pentylbenzenes, were determined for Hypersil 3 microm n-octylsilica and n-octadecylsilica packed into CEC capillary columns of 100 microm I.D., with a packed length of 250 mm, and a total length of 335 mm. The performances of these CEC capillary columns were examined for a variety of eluents with pH values ranging between pH 2.0 - 8.0, similar to those employed …

chemistry.chemical_classificationCapillary electrochromatographyChromatographyCapillary actionOrganic ChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyHydrocarbonchemistryElectrochromatographyAlkylbenzenesTheoretical plateChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

Capillary electrochromatography analysis of hormonal cyclic and linear peptides.

2001

The retention behavior of linear and cyclic peptides has been studied by capillary electrochromatography (CEC) with a variety of different n-alkyl silica reversed-phase sorbents and also with mixed-mode phases containing both strong cation-exchange (sulfonic acid) and n-alkyl groups bonded onto the silica surface, using eluents ranging from pH 2.0 to pH 5.0. Depending upon the amino acid sequence, electrochromatographic retention of the peptides was strongly affected by the composition of the eluent, its pH value, and the choice of sorbent packed into the capillaries. The dominant separation processes operating with these charged analytes could be modulated inter alia by the content of orga…

chemistry.chemical_classificationCapillary electrochromatographyChromatographySilicon dioxideSulfonic acidSilicon DioxidePeptides CyclicCyclic peptideHormonesAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyCapillary electrophoresischemistryElectrochromatographyAcetonitrileOligopeptidesChromatography Micellar Electrokinetic CapillaryAnalytical chemistry
researchProduct

1978

A reaction vessel automatically controlled by magnetic valves is described which allows kinetic measurements of reactions with half lives t1/2≥2s by gravimetric determination of the conversion. Thus, it covers the gap between the flow tube and the conventional reaction vessel. The influence of mixing time and filling time on the molecular weight distribution of an anionically prepared polymer is discussed.

chemistry.chemical_classificationChemical engineeringPolymerizationChemistryPolymer chemistryMixing (process engineering)Gravimetric analysisMolar mass distributionHalf-lifePolymerChemical reactorKinetic energyDie Makromolekulare Chemie
researchProduct