Search results for "Musculoskeletal diseases."
showing 10 items of 842 documents
A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
2018
Background Displaced transverse patellar fractures require open reduction and internal fixation. State-of-the-art stabilization techniques are tension band wiring (TBW) using Kirschner wires or cannulated screws. These techniques are associated with high rates of secondary fracture displacement, implant migration, implant prominence, wound-healing disturbances, and the need for implant removal. Recently, a locked intraosseous patellar nail prototype was developed. The aim of the present study was to investigate the biomechanical performance of this nail compared with TBW using cannulated screws. Methods Seven paired fresh-frozen human cadaveric knees were stripped of all soft tissues except…
Preliminary Experience with a Novel System of Facet Fixation to Treat Patients with Lumbar Degenerative Disease. A New Perspective in Minimally Invas…
2017
Purpose We report our experience with a novel surgical device for the treatment of lumbar degenerative microinstability. Facet Wedge (DePuy Synthes, Raynham, Massachusetts, United States) is a novel technique of intra-articular lumbar facet fixation that provides a minimally invasive alternative to standard posterior fixation. Materials and Methods From November 2014 to July 2015, 38 patients underwent single-level Facet Wedge implantation. The main surgical indications included herniated disk (18 patients), spinal canal and foraminal stenosis (14 patients), and Meyerding grade I degenerative spondylolisthesis (6 patients). All the patients showed radiologic signs of microinstability: hype…
Spinal anaesthesia in a patient with post-spine surgery dural ectasia.
2013
Dural sac ectasia is a very infrequent anatomical abnormality, usually caused by connective tissue diseases, as Marfan syndrome. Very few cases have been described being a consequence of a previous spine surgical procedure. We describe the case of an elderly patient who should be operated on twice due to sub-occlusive colon disease. Surgery was performed under spinal anaesthesia. A dural sac ectasia was suspected after the first procedure and the abdominal X-ray was reviewed. The characteristics of the anatomical alteration and the course of both anaesthetic procedures were described. X-ray and CT images were provided.
Correlation of Tibial Low-Frequency Ultrasound Velocity with Femoral Radiographic Measurements and BMD in Elderly Women
2009
The ultrasonic axial transmission technique has been proposed as a method for cortical bone characterization. Using a low enough center frequency, Lamb modes can be excited in long bones. Lamb waves propagate throughout the cortical bone layer, which makes them appealing for characterizing bone material and geometrical properties. In the present study, a prototype low-frequency quantitative ultrasonic axial transmission device was used on elderly women (n = 132) to investigate the relationships between upper femur geometry and bone mineral density (BMD) and tibial speed of sound. Ultrasonic velocities (V) were recorded using a two-directional measurement set-up on the midtibia and compared …
The role of biosilica in the osteoprotegerin/RANKL ratio in human osteoblast-like cells
2010
Abstract Earlier studies have demonstrated that biosilica, synthesized by the enzyme silicatein, induces hydroxyapatite formation in osteoblast-like SaOS-2 cells. Here we study the effect of biosilica on the expressions of osteoprotegerin [OPG] and the receptor activator for NF-κB ligand [RANKL] in the SaOS-2 cell model. We show that during growth of SaOS-2 cells on biosiliceous matrices hydroxyapatite formation is induced, while syntheses of cartilaginous proteoglycans and sulfated glycosaminoglycans are down-regulated. Furthermore, quantitative real-time RT-PCR analysis revealed a strong time-depended increase in expression of OPG in biosilica exposed SaOS-2 cells while the steady-state e…
Analysis of weight gain composition determined in preterm infants with Dual energy x-ray absorptiometry (DXA)
1999
Analysis of weight gain composition determined in preterm infants with Dual energy x-ray absorptiometry (DXA)
Residual Stress Effects on Fatigue Crack Growth in Ti-6Al-4V Friction Stir Welds
2008
Recent studies have illustrated a predominant role of the residual stress on the fatigue crack growth in friction stir welded joints. In this study, the role of the residual stress on the propagation of fatigue cracks orthogonal to the weld direction in a friction stir welded Ti-6Al-4V joint was investigated. A numerical prediction of the fatigue crack growth rate in the presence of the residual stresses was carried out using AFGROW software; reasonable correspondence between the predictions and the experimental results were observed when the effects of residual stress were included in the simulation.
Leg and joint stiffness in human hopping
2010
The present study investigated the regulation of leg and joint stiffness in hopping at different intensity levels. Eight male subjects performed bilateral hopping at various intensity levels that were determined by peak vertical ground reaction force (GRF). In addition to the GRF, the measurements included hopping kinematics and electromyography (EMG) of selected leg muscles. While the leg and ankle joint stiffness remained invariant, the knee joint stiffness increased significantly (P<0.01) with the hopping intensity. EMG analysis revealed a significant increase in averaged EMG for all the measured muscles before and during the early phase of ground contact (P<0.05-0.001) with increasing h…
Vergleich radiologischer Verfahren zur präoperativen Beurteilung der Verankerungsfestigkeit von Wirbelsäulenimplantaten
1997
PURPOSE To compare three techniques with regards to their ability to estimate pull out strength of spinal fusion hardware. MATERIAL AND METHODS VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pull out force measurement. Bone quality was assessed by Dual X-ray Absorptiometry (DXA). Quantitative Computed Tomography (QCT) and T2*-relaxation time. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS Highest correlation was found for cancellous bone density measured by QCT (r = 0.72; p < 0.001). Immediately followed by DXA (r = 0.70; p < 0.001), which involves all bone components. Inverted T2*-relax…
Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach
2020
Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…