Search results for "STIGMA"
showing 10 items of 286 documents
Effect of even and odd-order aberrations on the accommodation response
2017
Aim To investigate the potential effect that odd and even-order monochromatic aberrations may have on the accommodation response of the human eye. Methods Eight healthy subjects with astigmatism below 1 D, best corrected visual acuity 20/20 or better and normal findings in an ophthalmic examination were enrolled. An adaptive optics system was used in order to measure the accommodation response of the subjects' eyes under different conditions: with the natural aberrations being present, and with the odd and even-order aberrations being corrected. Three measurements of accommodation response were monocularly acquired at accommodation demands ranging from 0 to 4 D (0.5 D step). Results The acc…
Acs refrakcija un viņas noteikšana
1933
Titullapā norādīts autors: Apiņš, Kārlis
Statistical analysis when dealing with astigmatism: assessment of different spherocylindrical notations.
2001
Ophthalmic epidemiological studies frequently deal with ocular refractive errors, which are commonly expressed in the form sphere/cylinder x axis. However, this representation has been shown not to be the most suitable one for performing statistical analysis. Although alternative analytical and graphic methods to represent this kind of data have been developed, these formalisms have often gone unnoticed by researchers, despite their usefulness and versatility. Besides, there has been no discussion of how each of them fits in with a particular type of study. In this paper, several mathematical representations of dioptric power are revisited in a comprehensive way. The aim is to encourage res…
Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering
2012
To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…
Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia
2019
PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…
Residual astigmatism produced by toric intraocular lens rotation.
2010
Purpose To analyze changes in the eye’s refractive properties when a toric intraocular lens (IOL) rotates. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Design Experimental study. Methods The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C1 and C2 whose axes form an angle a, is obtained by the addition of 2 vectors of values C1 and C2 forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part Fnes, the orth…
Lateral magnification matrix from the dioptric power matrix formalism in the paraxial case.
2012
Background Previous studies have highlighted that power matrices fully characterize the concept of dioptric power of any astigmatic surface. Thus, the basic equations in physiological optics can be generalized using the matrix formalism of the dioptric power. Among others, lateral magnification has also been interpreted as a matrix but mainly concerning magnification modification induced by spectacle correction of refractive error. Purpose To provide a fresh look into a novel paraxial formulation for the assessment of the lateral magnification using power matrices and in presence of astigmatism for thin and thick imaging systems in general. Methods Linear optics provides the frame to genera…
The Dynamics of (De)Stigmatization : Boundary construction in the nascent category of organic farming
2020
This study finds that it is possible for organizations in emerging categories to resist stigmatization through discursive reconstruction of the central and distinctive characteristics of the category in question. We examined the emerging market of organic farming in Finland and discovered how resistance to stigmatization was both an internal and an external power struggle in the organic farming community. Over time, the label of organic farming was manipulated and the practice of farming was associated with more conventional and familiar contexts, while the stigma was diverted at the same time to biodynamic farming. We develop a process model for removal of stigma from a nascent category t…
Transconjunctival sutureless 25-Gauge versus 20-Gauge standard vitrectomy: correlation between corneal topography and ultrasound biomicroscopy measur…
2009
Purpose: To determine the correlation between corneal shape changes and ultrasound biomicroscopy (UBM) findings at the sclerotomy sites in conventional 20-gauge (G) pars plana vitrectomy (PPV) and 25-G transconjunctival sutureless vitrectomy (TSV) and to compare the effectiveness of the two surgical methods. Design: Prospective, comparative, observational case series. Methods: Sixty consecutive eyes (60 patients) undergoing primary 3-port PPV. Thirty eyes (30 patients, group 20-G) were treated with 20-G standard PPV and 30 eyes (30 patients, group 25-G) with 25-G TSV. We compared healing of the sclerotomy sites in the two groups. We determined the correlation between corneal shape changes (…
The posterior chamber phakic refractive lens (PRL): a review
2012
Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…