Search results for "Signal"
showing 10 items of 6924 documents
A discrimination technique for extensive air showers based on multiscale, lacunarity and neural network analysis
2011
We present a new method for the identification of extensive air showers initiated by different primaries. The method uses the multiscale concept and is based on the analysis of multifractal behaviour and lacunarity of secondary particle distributions together with a properly designed and trained artificial neural network. In the present work the method is discussed and applied to a set of fully simulated vertical showers, in the experimental framework of ARGO-YBJ, to obtain hadron to gamma primary separation. We show that the presented approach gives very good results, leading, in the 1–10 TeV energy range, to a clear improvement of the discrimination power with respect to the existing figu…
Interpretation of KPFM Data with the Weight Function for Charges
2018
The KPFM signal for systems containing local charges can be expressed as a weighted sum over all local charges. The weight function for charges quantifies the contribution of each charge, depending on its position. In this chapter, we evaluate the KPFM weight function for charges by analyzing several application-relevant model systems. The intention of this chapter is to provide insights into the KPFM contrast formation in order to facilitate the KPFM data interpretation. For this, we concentrate on three model systems: (A) a conductive sample in ultra-high vacuum, (B) a dielectric sample in ultra-high vacuum, and (C) a dielectric sample in water. We calculate the weight function for charge…
The use of the integral-bias summing coincidence spectrometer in directional correlation measurements
1968
Abstract The performance of the integral-bias summing coincidence spectrometer (the sum-peak spetrometer) in measurements of directional correlations of gamma rays has been tested. As compared with the conventional method, the sum-peak spectrometer is easier to use and seems to yield results which agree with those obtained with the ordinary method. Because of the complex shapes of response functions of gamma rays above about 3 MeV, the new method is best suited to the study of cascading transitions below this energy, where the two methods appear to complement each other. The analysis of the sum-peak spectra in the present work is based on a simple graphical method which seems to yield satis…
Calibration of the XRT-SOLARB flight filters at the XACT facility of INAF-OAPA
2004
The X-Ray Telescope (XRT) experiment on-board the Japanese satellite SOLAR-B (launch in 2006) aimed at providing full Sun field of view at ~ 1.5" angular resolution, will be equipped with two wheels of focal-plane filters to select spectral features of X-ray emission from the Solar corona, and a front-end filter to significantly reduce the visible light contamination. We present the results of the X-ray calibrations of the XRT flight filters performed at the X-ray Astronomy Calibration and Testing (XACT) facility of INAF-OAPA. We describe the instrumental set-up, the adopted measurement technique, and present the transmission vs. energy and position measurements.
Contour detection based on nonlinear discrete diffusion in a cellular nonlinear network
2001
International audience; A contour detection based on a diffusive cellular nonlinear network is proposed. It is shown that there exists a particular nonlinear function for which, numerically, the obtained contour is satisfactory. Furthermore, this nonlinear function can be achieved using analog components.
Diffusion effects in a nonlinear electrical lattice
1998
International audience; We consider a nonlinear electrical network modeling the generalized Nagumo equation. Focusing on the particular case where the initial load of the lattice consists in the superimposition of a coherent information weakly varying in space and a perturbation of small amplitude, we show that the perturbation can be eliminated quickly, almost without disturbing the information.
Comparaison de la mesure des déformations de fantômes de l’aorte à partir d’image obtenues par IRM et stéréovision
2015
International audience; The study of the wall strain distribution could be helpful to improve the decision criterion for surgery of aortic aneurysm. Recently, numerical simulations can complete the data obtained from imaging measurement in order to develop reliable models. However, the used medical imaging tools are not experimentally validated, in metrological point of view. The aim of this study focused on accuracy and reliability of measurement obtained from kinetic MR sequences. The measures of deformations from MRI were compare to those obtained from stereovision system. Cylindrical phantom of silicone material similar to arterial behavior simulated a symmetric aneurysm was designed. A…
Field-free molecular alignment for measuring ionization probability
2007
International audience; We have shown in a recent letter (Loriot et al 2006 Opt. Lett. 31 2897) the possibility of determining the ionization probability of linear molecules by using an all-optical technique that takes advantage of post-pulse molecular alignment. To that end, we have implemented a ‘cross-defocusing' technique producing a signal sensitive to both alignment and ionization. The analysis of the signal provides a quantitative measurement of the ionization probability calibrated with molecular alignment. In the present work, the method is discussed in more detail and applied to the measurement of the ionization probability of N2 as well as to the determination of the ionization r…
Complete nonlinear polarization control in an optical fiber system.
2010
International audience; We consider the counterpropagating interaction of a signal and a pump beam in an isotropic optical fiber. On the basis of recently developed mathematical techniques, we show that an arbitrary state of polarization of the signal beam can be converted into any other desired state of polarization. On the other hand, an unpolarized signal beam may be repolarized into two specific states of polarization, without loss of energy. Both processes of repolarization and polarization conversion may be controlled by adjusting the polarization state of the backward pump.
Extreme statistics in Raman fiber amplifiers : from experiments to analytical description
2010
International audience; We describe the concept of an all-fibered device that enables the optical magnification of the amplitude jitter of low-fluctuation pulse trains, facilitating the measurement of the statistical properties by usual photodiodes and electronic equipments. Taking advantage of a highly nonlinear fiber with anomalous dispersion followed by central optical bandpass filtering, we experimentally demonstrate an amplification of small-scale fluctuations by a factor 10.