Search results for "Standards"

showing 10 items of 394 documents

Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors

2014

Selected volatile organic compounds (VOCs) in breath may be considered biomarkers if they are indicative of distinct diseases or disease states. Given the inherent molecular selectivity of vibrational spectroscopy, infrared sensing technologies appear ideally suitable for the determination of endogenous VOCs in breath. The aim of this study was to determine that mid-infrared (MIR; 3-20 µm) gas phase sensing is capable of determining isoprene in exhaled breath as an exemplary medically relevant VOC by hyphenating novel substrate-integrated hollow waveguides (iHWG) with a likewise miniaturized preconcentration system. A compact preconcentrator column for sampling isoprene from exhaled breath …

Pulmonary and Respiratory MedicineDetection limitTime FactorsInfrared RaysTemperatureAnalytical chemistryInfrared spectroscopySignal Processing Computer-AssistedBiosensing TechniquesSubstrate (electronics)Reference StandardsHollow waveguidechemistry.chemical_compoundHemiterpenesBreath TestsBreath gas analysischemistryPentanesTemporal resolutionCalibrationButadienesCalibrationHumansIsopreneJournal of Breath Research
researchProduct

Comparison of quantitative analysis techniques for the determination of heat seal lacquer layers on aluminum blister foils

2010

For decades a gravimetric method has been common standard for the determination of heat seal lacquers on aluminum blister foils. With the availability of appropriate techniques such as interferometric, infrared reflection absorption spectroscopic (IRRAS), beta backscatter, impedance spectroscopic and eddy current techniques respectively, more efficient determinations can be foreseen which are subject of the present communication. The different methods were compared to each other regarding parameters required for validation of analytical procedures according to the ICH guidelines Q2 (R1) such as linearity, precision, accuracy, robustness and quantitation limits. The interferometric, IRRAS an…

Quality ControlAbsorption (acoustics)Hot TemperatureMaterials scienceSpectrophotometry InfraredBackscatterPharmaceutical Scienceengineering.materiallaw.inventionOpticsCoatinglawEddy currentScattering RadiationElectrical impedanceDrug Packagingbusiness.industryLinearityReference StandardsInterferometryModels ChemicalCalibrationengineeringGravimetric analysisAnalytical proceduresbusinessPlasticsAluminumEuropean Journal of Pharmaceutical Sciences
researchProduct

Standardization of reagents and methods used in cytological and histological practice with emphasis on dyes, stains and chromogenic reagents

1994

The need for the standardization of reagents and methods used in the histology laboratory is demonstrated. After definitions of dyes, stains, and chromogenic reagents, existing standards and standards organizations are discussed. This is followed by practical instructions on how to standardize dyes and stains through the preparation of reference materials and the development of chromatographic methods. An overview is presented of the problems concerned with standardization of the Romanowsky-Giemsa stain for cytological and histological application. Finally, the problem of how to convince routine dye and stain users of the need for standardization in their histology laboratories is discussed.

Quality ControlChromatographyStaining and LabelingStandardizationChemistryChromogenicCytological TechniquesHistological TechniquesCell BiologyReference StandardsStainStainingInvestigation methodsChromogenic CompoundsAnimalsHumansAnatomyColoring AgentsReference standardsThe Histochemical Journal
researchProduct

Quality control Fourier transform infrared determination of diazepam in pharmaceuticals

2007

A quality control procedure has been developed for the determination of diazepam in pharmaceuticals using Fourier transform infrared (FTIR) spectroscopy. The method involves the off-line extraction of diazepam with chloroform by sonication and direct determination in the extracts through peak area measurement in the interval between 1672 and 1682 cm(-1) using a baseline correction defined between 1850 and 1524 cm(-1). For standardization it was used an external calibration line established from standard solutions of diazepam in chloroform. The method provides a limit of detection of 0.04 mg per tablet (n=5), a relative standard deviation (R.S.D.) of 0.5% for 5 independent measurements of a …

Quality ControlClinical BiochemistryAnalytical chemistryPharmaceutical ScienceInfrared spectroscopyStandard solutionAnalytical Chemistrysymbols.namesakechemistry.chemical_compoundSpectrophotometrySpectroscopy Fourier Transform InfraredDrug DiscoveryCalibrationmedicineFourier transform infrared spectroscopySpectroscopyDetection limitDiazepamChromatographyChloroformmedicine.diagnostic_testChemistryReference StandardsFourier transformAnti-Anxiety AgentsPharmaceutical PreparationsCalibrationsymbolsSpectrophotometry UltravioletTabletsJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Toward a Quality Guide to Facilitate the Transference of Analytical Methods from Research to Testing Laboratories: A Case Study

2009

Abstract At present, there is no single viewpoint that defines QA strategies in analytical chemistry. On the other hand, there are no unique protocols defining a set of analytical tasks and decision criteria to be performed during the method development phase (e.g., by a single research laboratory) in order to facilitate the transference to the testing laboratories intending to adapt, validate, and routinely use this method. This study proposes general criteria, a priori valid for any developed method, recommended as a provisional quality guide containing the minimum internal tasks necessary to publish new analytical method results. As an application, the selection of some basic internal qu…

Quality ControlComputer sciencemedia_common.quotation_subjectChemistry Techniques AnalyticalAnalytical ChemistrySet (abstract data type)Environmental ChemistryComputer SimulationQuality (business)Differential (infinitesimal)Publicationmedia_commonPharmacologyNitratesbusiness.industryReproducibility of ResultsReference StandardsMultiple-criteria decision analysisMethod developmentInternal qualitySystems engineeringA priori and a posterioriIndicators and ReagentsLaboratoriesbusinessMonte Carlo MethodAgronomy and Crop SciencePolarographyFood ScienceJournal of AOAC INTERNATIONAL
researchProduct

Chromatographic multivariate quality control of pharmaceuticals giving strongly overlapped peaks based on the chromatogram profile

2004

In the present paper, the simultaneous quantification of two analytes showing strongly overlapped chromatographic peaks (alpha = 1.02), under the assumption that both available equipment and training of the laboratory staff are basic, is studied. A pharmaceutical preparation (Mutabase) containing two drugs of similar physicochemical properties (amitriptyline and perphenazine) is selected as case of study. The assays are carried out under realistic working conditions (i.e. routine testing laboratories). Uncertainty considerations are introduced in the study. A partial least squares model is directly applied to the chromatographic data (with no previous signal transformation) to perform quali…

Quality ControlProtocol (science)Multivariate statisticsAnalyteChromatographyChemistryOrganic ChemistryGeneral MedicineReference StandardsPharmaceutical formulationBiochemistryAnalytical ChemistryChemometricsQuality (physics)Pharmaceutical PreparationsApproximation errorMultivariate AnalysisPartial least squares regressionJournal of Chromatography A
researchProduct

Plasma pharmacokinetics and tissue distribution study of cajaninstilbene acid in rats by liquid chromatography with tandem mass spectrometry

2010

Cajaninstilbene acid (CSA; 3-hydroxy-4-prenyl-5-methoxystilbene-2-carboxylic acid) is a major active constituent of pigeonpea leaves, has been proven to be effective in clinical treatment of diabetes, hepatitis, measles and dysentery. A rapid and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of CSA in rat plasma and various tissues (brain, heart, lung, liver, spleen, small intestine and kidney) of rat for the first time. Rat plasma and tissue distribution pre-treated by protein precipitation with acetoacetate was analyzed using LC-MS/MS with an electrospray ionization (ESI) interface, and isoliquiritigenin was us…

Quality ControlTime FactorsMetabolic Clearance RateFormic acidElectrospray ionizationClinical BiochemistryCarboxylic AcidsPharmaceutical ScienceTandem mass spectrometrySensitivity and SpecificityHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundCajanusDrug StabilityPharmacokineticsTandem Mass SpectrometryLiquid chromatography–mass spectrometryFreezingStilbenesDrug DiscoveryAnimalsProtein precipitationTissue DistributionSpectroscopyChromatographyMolecular StructureTemperatureReproducibility of ResultsHalf-lifeRats Inbred StrainsReference StandardsSalicylatesRatschemistryArea Under CurveCalibrationFemaleChromatography LiquidHalf-LifeJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Search for the Associated Production of the Standard-Model Higgs Boson in the All-Hadronic Channel

2009

We report on a search for the standard-model Higgs boson in pp collisions at s=1.96 TeV using an integrated luminosity of 2.0 fb(-1). We look for production of the Higgs boson decaying to a pair of bottom quarks in association with a vector boson V (W or Z) decaying to quarks, resulting in a four-jet final state. Two of the jets are required to have secondary vertices consistent with B-hadron decays. We set the first 95% confidence level upper limit on the VH production cross section with V(-> qq/qq('))H(-> bb) decay for Higgs boson masses of 100-150 GeV/c(2) using data from run II at the Fermilab Tevatron. For m(H)=120 GeV/c(2), we exclude cross sections larger than 38 times the standard-m…

QuarkParticle physicsStandardsFinal stateFermilab TevatronHiggs bosonTevatronFOS: Physical sciencesGeneral Physics and AstronomyElementary particleddc:500.201 natural sciences114 Physical sciencesStandard ModelVector bosonHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)Particle decayTellurium compounds0103 physical sciencesJetsB-hadron decaysHigh energy physics010306 general physicsBosonsBosonStandard-model Higgs bosonsPhysicsIntegrated luminosityHIGGS BOSONModel predictionCross section010308 nuclear & particles physicsPhysicsHigh Energy Physics::PhenomenologyConfidence levelsUpper limits3. Good healthVector bosonProduction cross sectionBottom quarksSecondary verticesHiggs bosonCDFHigh Energy Physics::Experiment
researchProduct

Internet of Things – Emergence of standards

2012

Poikolainen, Janne Internet of Things – Emergence of standards Jyväskylä: University of Jyväskylä, 2012, 34 p. Information System Science, Bachelor's Thesis Supervisor: Mazhelis, Oleksiy Internet of Things is a paradigm referring to the pervasive presence of networked things and objects that are able to interact and cooperate with each other. This paradigm also suggests that in the future these objects also produce large amounts of data to the internet and other network applications. Predictions say that the amount of data produced by things proceeds human produced data in the near future. These visions are grounded in the assumption that the advances in microelectronics, communications and…

RFIDIoTStandardsSensor networkInternet of ThingsStandardization issues
researchProduct

Quality of reporting in abstracts of RCTs published in emergency medicine journals: a protocol for a systematic survey of the literature

2017

Introduction The quality of reporting of abstracts of randomised controlled trials (RCTs) in major general medical journals and in some category-specific journals was shown to be poor before the publication of the ConsolidatedStandards of ReportingTrials (CONSORT) extension for abstracts in 2008, and an improvement in the quality of reporting of abstracts was observed after its publication. The effect of the publication of the CONSORT extension for abstracts on the quality of reporting of RCTs in emergency medicine journals has not been studied. In this paper, we present the protocol of a systematic survey of the literature, aimed at assessing the quality of reporting in abstracts of RCTs p…

Research Reportmedicine.medical_specialtyResearch methodologySystematic surveymedia_common.quotation_subjectAlternative medicineAccident & emergency medicine03 medical and health sciences0302 clinical medicineQuality of reportingProtocolMedicineHumansQuality (business)030212 general & internal medicine1506Abstractmedia_commonRandomized Controlled Trials as TopicProtocol (science)Research ethicsImpact factorbusiness.industryPublicationsConsolidated Standards of Reporting Trials030208 emergency & critical care medicineGeneral Medicinehumanities1691Statistics &research methodsEmergency medicineEmergency MedicineMedline databasebusinessBMJ Open
researchProduct