Search results for "X-Ray"
showing 10 items of 4234 documents
EBIT diagnostics using X-ray spectra of highly ionized Ne
2003
We have carried out a detailed analysis of highly ionized neon spectra collected at the NIST EBIT using an NTD germanium X-ray microcalorimeter developed at the Harvard-Smithsonian Center for Astrophysics [Nucl. Instr. and Meth. A 444 (2000) 156]. Our attention was focused especially on the Ne IX He-like triplet to check electron density diagnostics through the intercombination/forbidden line ratio. We have investigated possible effects of the ion dynamics on the plasma emission line intensities, looking at the dependence of the count-rate and the charge state distribution on the electron beam energy and current. The temperature and spatial distribution of the neon ions, and hence the overl…
Local structure studies of SrTi16O3and SrTi18O3
2014
In this work we report on the local structure of Ti in SrTi 16 O3 (STO16) and SrTi 18 O3 (STO18) investigated in the low temperature range (6‐300K) by extended x-ray absorption fine structure and x-ray absorption near edge structure (XANES) spectroscopy at Ti K-edge and by optical second harmonic generation (SHG). By comparing XANES of STO16 and STO18 we have identified the isotopic effect which produces at T < 100K a noticeable difference in the measured mean square relative displacements (MSRD) of Ti‐O1 bonds: while STO16 follow the expected Einstein-like behavior, for STO18 we have measured an increase of MSRD values with decreasing temperature. This is an indication of an increasing off…
Large 256-Pixel X-ray Transition-Edge Sensor Arrays With Mo/TiW/Cu Trilayers
2015
We describe the fabrication and electrical characterization of 256-pixel X-ray transition-edge sensor (TES) arrays intended for materials analysis applications. The processing is done on 6-in wafers, providing capabilities on a commercial scale. TES films were novel proximity coupled Mo/TiW/Cu trilayers, where the thin TiW layer in between aims to improve the stability of the devices by preventing unwanted effects such as Mo/Cu interdiffusion. The absorber elements were electrodeposited gold of thickness 2 μm. The single-pixel design discussed here is the so-called Corbino geometry. Most design goals were successfully met, such as the critical temperature, thermal time constant, and transit…
X-ray Spectroscopy of (Ba,Sr,La)(Fe,Zn,Y)O3-δIdentifies Structural and Electronic Features Favoring Proton Uptake
2020
Mixed protonic–electronic conducting oxides are key functional materials for protonic ceramic fuel cells. Here, (Ba,Sr,La)(Fe,Zn,Y)O3−δ perovskites are comprehensively investigated by X-ray spectroscopy (in oxidized and reduced states). Extended X-ray absorption fine structure shows that Zn,Y doping strongly increases the tendency for Fe–O–Fe buckling. X-ray absorption near-edge spectroscopy at the Fe K-edge and X-ray Raman scattering at the O K edge demonstrate that both iron and oxygen states are involved when the samples are oxidized, and for the Zn,Y doped materials, the hole transfer from iron to oxygen is less pronounced. This can be correlated with the observation that these material…
Microscopic defects and impurity analyses of multicrystalline silicon solar cells from different manufacturing routes
2013
It is important to fully understand the physical behavior of solar cells made by materials from alternative process routes. Solar cells from Elkem Solar Grade Silicon and standard polysilicon have been investigated with light beam induced current and electroluminescence imaging. The low efficiency regions have been further analyzed by Scanning Electron Microscopy under different imaging modes. It was found that cell regions of low performance had undergone plastic deformations resulting in the creation of crystalline defects appearing as subgrain patterns. Similar patterns were observed in both ESS™ and standard polysilicon. Energy-dispersive X-ray spectroscopy (EDS) and electron backscatte…
Hard-X-ray-induced excited-spin-state trapping.
2007
Time-dependent current-voltage characteristics of Al/p-CdTe/Pt x-ray detectors
2012
Current-voltage (I-V) characteristics of Schottky Al/p-CdTe/Pt detectors were investigated in dark and at different temperatures. CdTe detectors with Al rectifying contacts, very appealing for high resolution x-ray and gamma ray spectroscopy, suffer from bias-induced polarization phenomena which cause current increasing with the time and severe worsening of the spectroscopic performance. In this work, we studied the time-dependence of the I-V characteristics of the detectors, both in reverse and forward bias, taking into account the polarization effects. The I-V measurements, performed at different time intervals between the application of the bias voltage and the measurement of the current…
Quantitative molecular plating of large-area 242Pu targets with improved layer properties
2015
Abstract For measurements of the neutron-induced fission cross section of 242Pu, large-area (42 cm2) 242Pu targets were prepared on Ti-coated Si wafers by means of constant current density molecular plating. Radiochemical separations were performed prior to the platings. Quantitative deposition yields (>95%) were determined for all targets by means of alpha-particle spectroscopy. Layer densities in the range of 100–150 μg/cm2 were obtained. The homogeneity of the targets was studied by radiographic imaging. A comparative study between the quality of the layers produced on the Ti-coated Si wafers and the quality of layers grown on normal Ti foils was carried out by applying scanning electron…
Using photoelectron emission microscopy with hard-X-rays
2001
We present several successful test cases of using photoelectron emission microscopy (PEEM) for photon energy up to 25 keV. First, the full extended X-ray absorption fine structure analysis was implemented in areas as small as 100 mum(2) for transition-metal K edge absorption spectra and, therefore, demonstrated the feasibility of combining structural and chemical analysis with hard-X-ray absorption spectroscopy with high lateral resolution. We also show that PEEM can be used in a transmission (radiography) mode as an imaging detector for hard-X-ray, This approach again leads to the unprecedented 0.3 mum lateral resolution, particularly critical for the use of coherence-based phase contrast …
Jahn-Teller distortion aroundFe4+inSr(FexTi1−x)O3−δfrom x-ray absorption spectroscopy, x-ray diffraction, and vibrational spectroscopy
2007
$\mathrm{Sr}({\mathrm{Fe}}_{x}{\mathrm{Ti}}_{1\ensuremath{-}x}){\mathrm{O}}_{3\ensuremath{-}\ensuremath{\delta}}$ perovskites (strontium titanate ferrite solid solution) with well-defined oxygen stoichiometry have been studied as a function of iron concentration by x-ray diffraction, Fe and Ti $K$-edge x-ray absorption spectroscopy (XAS), and vibrational (Raman and infrared) spectroscopy. In reduced $\mathrm{Sr}({\mathrm{Fe}}_{x}{\mathrm{Ti}}_{1\ensuremath{-}x}){\mathrm{O}}_{3\ensuremath{-}x∕2}$ samples, the analysis of the Fe $K$-edge extended x-ray absorption fine structure indicates the expected presence of oxygen vacancies ${\mathrm{V}}_{\mathrm{O}}^{∙∙}$ in the first coordination shell…