Search results for "chirurgia"
showing 10 items of 1439 documents
Endograft connector technique to treat popliteal artery aneurysm in a morbid obese patient.
2015
Surgical repair of popliteal artery aneurysm in morbid obese patients poses additional challenges. We report a morbid obese patient who had a 59 mm right popliteal artery aneurysm which was successfully treated with the endograft connector technique. This technique was used to perform the distal anastomosis of the below-knee femoro-popliteal bypass. A 10 mm Dacron graft was used as a main graft bypass and an 11 mm/10 cm stentgraft as endograft connector. Following the respective tunnel of the Dacron graft, an end-to-side proximal anastomosis was performed at distal femoral artery. The aneurysm exclusion was obtained through a proximal and a distal ligation. Postoperative duplex showed adeq…
Post Surgical Pyoderma Gangrenosum in flap surgery: diagnostic clues and treatment recommendations
2016
Background: Post Surgical Pyoderma Gangrenosum (PSPG) is a neutrophilic dermatosis causing aseptic necrotic ulcerations within surgical sites. It is often misdiagnosed as infection or ischemia and worsened by the inappropriate treatment. Therefore diagnostic clues must be identified and awareness for PSPG raised.Methods: We present two cases of PSPG after flap surgery and a review of the literature.Results: Seventeen cases of PSPG after flap surgery were found. Fever, pain and redness are the most common initial symptoms. In 63%, lesions were on the flap and the adjacent skin. In 63%, the donor site is also involved. Time to diagnosis was nine days to four years. Frequent debridement (89%) …
Complications of trans-anastomotic externalised stents in open pyeloplasty: influence of the method of placement, the duration of stenting, and the a…
2010
To assess the influence of the method for stent placement, the duration of stenting, and the presence of bladder drainage on the complication rate of open pyeloplasty. Patients and methods: Complications were, retrospectively, compared in 228 consecutive open pyeloplasties performed at institution A using a trans-pyelostomic 6-Fr splint/stent for 5 days and no bladder drainage, and 150 consecutive open pyeloplasties performed at institution B using a trans-nephrostomic 6-Fr splint/stent for 9 days plus bladder drainage. Results: Median age at surgery was comparable between groups. The overall complication rate was 13% and was comparable at the two institutions, but for the presence of perio…
Anterior cervical discectomy and fusion with ROI-C peek cage: cervical alignment and patient outcomes
2014
OBJECTIVE: The intersomatic cage ROI-C one is a new promising system in anterior cervical discectomy with subsequent fusion. METHODS: Patients were studied prospectively. ROI-C cages were used in consecutive 32 patients. Intraoperative parameters, clinical features and dysphagia scores were recorded. Radiographs evaluated the height of intervertebral space, the cervical Cobb angle and implant positioning. Data were collected on the last day of hospital stay, at 6 weeks, at 3, 6, 12 and 24 months. RESULTS: A total of 32 cages were implanted. One patient had transient dysphagia. The intervertebral height and the cervical Cobb angle were significantly improved at 24 months follow-up (P < 0.05)…
A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm
2013
We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.
Endovascular treatment options for complex abdominal aortic aneurysms
2015
Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …
Perfusion computed tomography of intracranial meningiomas: In vivo correlation of cerebral blood volume and vascular permeability
2015
Background A noninvasive method to predict the grade of a meningioma would be desirable since it would anticipate information about tumour nature, recurrence and improve tumour management and outcomes. The aim of the present study was to assess the ability of perfusion computed tomography (PCT) technique in predicting the meningioma grade before surgery. Data from PCT, such as cerebral blood volume (CBV) and permeability surface (PS), were correlated with immunohistolopathological information. Methods Twenty-three patients with a diagnosis of intracranial meningioma underwent PCT for pre-surgical evaluation of CBV and PS. During surgery, samples from the centre and periphery of the tumour w…
Detection of flap venous and arterial occlusion using interstitial glucose monitoring in a rodent model.
2010
Background: Free tissue transfer necessitates vigilant postoperative monitoring for vessel occlusion. Unfortunately, most monitoring methods require experienced personnel and are expensive to use. Furthermore, many tests have low sensitivity, low specificity, or significant delay between vessel occlusion and detection. The authors report on a novel method of tissue monitoring that avoids these limitations by tracking interstitial glucose concentration. Methods: Vertical rectus abdominis myocutaneous flaps were elevated in adult rats based on the superior epigastric vessels. Interstitial glucose within the flaps was monitored using a transcutaneous sensor. Interstitial glucose was recorded f…
Recurrent abdominal pain in Chilaiditi's syndrome could represent an indication for elective surgery?
2011
Not available (Brief Report)
Preoperative evaluation of peripheral nerve injuries: What is the place for ultrasound?
2016
OBJECTIVE The purpose of this study was to evaluate the usefulness of ultrasound in the preoperative workup of peripheral nerve lesions and illustrate how nerve ultrasonography can be integrated in routine clinical and neurophysiological evaluation and in the management of focal peripheral nerve injuries. The diagnostic role and therapeutic implications of ultrasonography for different neuropathies are described. METHODS The authors analyzed the use of ultrasound in 119 entrapment, tumoral, posttraumatic, or postsurgical nerve injuries of limbs evaluated in 108 patients during 2013 and 2014. All patients were candidates for surgery, and in all cases the evaluation included clinical examina…