Search results for "detector"
showing 10 items of 3491 documents
The Cryogenic Anticoincidence Detector for ATHENA-XMS
2012
The TES cryogenic detectors, due to their high spectral resolution and imaging capability in the soft X-ray domain, are the reference devices for the next proposed space missions whose aims are to characterize the spectra of faint or diffuse sources. ATHENA is the re-scoped IXO mission, and one of its focal plane instrument is the X-ray Microcalorimeter Spectrometer (XMS) working in the energy range 0.3-10 keV. XMS will be able to achieve the proposed scientific goals if a background lower than 0.02 cts/cm2/s/keV is guaranteed. The studies performed by GEANT4 simulations depict a scenario where it is mandatory to use an active Anti-Coincidence (AC) to reduce the expected background in the L…
Enhancing the sensitivity of recoil-beta tagging
2013
Tagging with β-particles at the focal plane of a recoil separator has been shown to be an effective technique for the study of exotic proton-rich nuclei. This article describes three new pieces of apparatus used to greatly improve the sensitivity of the recoil-beta tagging technique. These include a highly-pixelated double-sided silicon strip detector, a plastic phoswich detector for discriminating high-energy β-particles, and a charged-particle veto box. The performance of these new detectors is described and characterised, and the resulting improvements are discussed.
Electrostatically operated micromirrors for a Hadamard transform spectrometer
2002
The paper presents the development of a linear micromirror array which can be used as a switchable entrance mask for a double-array Hadamard transform spectrometer. In addition to the detector array the double-array spectrometer has a linear multi-slit array realised by independently switchable micromirrors at the entrance side. Two different switch positions of the electrostatically operated mirrors allow the reflection of light into or away from the spectrometer. With this arrangement (mirror array, concave grating and array detector) and the use of the Hadamard transform principle it is possible to increase the signal-to-noise ratio and the resolution of the system compared to convention…
Oscillating ultra-cold neutron spectrometer
2019
The energy spectrum of ultra-cold neutrons (UCN) is very often a key point to determine the systematic effects in precision measurements utilizing UCN. The proposed novel method allows the in-situ measurements of the UCN velocity distribution and its time evolution. In addition, the proposed UCN spectrometer can be a handy diagnostic tool for monitoring the UCN spectrum in critical places in the transport system connecting an UCN source with experiments. In this paper, we present the preliminary results from measurements and simulations using the oscillating UCN spectrometer at the PSI UCN source.
A Ge(Li)Ge(Li) sum-peak (summing coincidence) spectrometer
1970
Abstract The sum-peak spectrometer (also called the integral-bias summing coincidence spectrometer) arrangement earlier developed with NaI(Tl) detectors is extended to Ge(Li) detectors. The integral-bias method in sorting sums of coincident pulse amplitudes is replaced by a set of pulse-height selection windows, which simply and more effectively aid in the analysis of sum-peak complexities associated with the symmetric linear summing procedure employed. A large part of the original information lost in summing of the pulse amplitudes can be retained by simultaneous sorting of the total spectrum into suitable subgroups. The arrangement represents in effect a real-time totalizing spectrometer …
COMMISSIONING OF THE SPEDE SPECTROMETER WITH STABLE BEAMS
2017
The SPectrometer for Electron DEtection (SPEDE) has been constructed for in-beam nuclear structure studies using radioactive ion beams. SPEDE employs a silicon detector for detecting conversion electrons. It is designed to be used in conjunction with the MINIBALL spectrometer at HIE-ISOLDE, CERN. Peer reviewed
A ten-fold divided total absorption Ge(Li) gamma-ray detector
1976
Abstract We have constructed a split-crystal total absorption Ge(Li) gamma-ray spectrometer and special logic electronics for rejecting Compton continuum in spectra. A 10 cm3 planar detector was divided into ten electrically separated detectors by grinding nine parallel slots on the n-surface of the detector. In operation both the n- and p-contacts are isolated from the ground. Using capacitive sharing, most of the released electrical charge is taken from the p-contact into an ordinary pulse amplifier line and analyzed. A small fraction of the charge collected at the n-strips is observed with voltage-sensitive FET-preamplifiers. The following logic electronics provides a gate pulse for the …
SphinX: A fast solar Photometer in X-rays
2008
The scientific goals and construction details of a new design, Polish X-ray spectrophotometer are given. It will be incorporated within the Russian TESIS X and EUV complex aboard the forthcoming CORO-NAS solar mission. SphinX (Solar Photometer in X-rays) will use PIN silicon detectors for high time resolution (0.01 s) measurements of the solar spectra of quiet and active corona in the range 0.5–15 keV. A new filter-fluorescence target concept will be employed to allow for a fast photometry of the solar X-ray flux variations in selected, well defined narrow spectral bands including the Fe XXVI and Fe XXV iron line groups.
Fundaments of photoelectric readout of spin states in diamond
2021
Abstract The chapter “Fundaments of photoelectric readout of spin states in diamond” deals with the detection of NV centre spins in diamond using the photoelectric detection of magnetic resonances (PDMR) method, introduced in a series of recent publications. It provides in particular insights into the physics of electronic transitions of the NV center, leading to the free carrier generation, and discusses methodologies how to implement the photocurrent detection principles in the dynamically evolving field of quantum technologies. Recent results on the single electron and the single nuclear spin qubits photoelectric readout are presented, along with a microwave-free NV magnetometry techniqu…
Solar Neutrino Spectroscopy
2017
More than forty years after the first detection of neutrinos from the Sun, the spectroscopy of solar neutrinos has proven to be an on-going success story. The long-standing puzzle about the observed solar neutrino deficit has been resolved by the discovery of neutrino flavor oscillations. Today's experiments have been able to solidify the standard MSW-LMA oscillation scenario by performing precise measurements over the whole energy range of the solar neutrino spectrum. This article reviews the enabling experimental technologies: On the one hand mutli-kiloton-scale water Cherenkov detectors performing measurements in the high-energy regime of the spectrum, on the other end ultrapure liquid-s…