Search results for "fault"
showing 10 items of 610 documents
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…
A General Mathematical Model for non-Redundant Fault-Tolerant Inverters
2011
Industrial systems able to release trusted services is an integrated concept that resumes the attributes of availability, reliability, safety, integrity, and maintainability. In power electronics this can be aimed via the introduction of fault tolerant architectures. While In the past technical literature the mathematical modeling problem for non-redundant converters was fronted studying separately the cases of fault leg by leg, in this paper a general model able to include the three possible cases of leg faults with a unique set of equation is introduced and discussed. The same model allows to evaluate the DC Link transient and steady state evolution and also allows to develop with much ea…
Flexible power converters for the fault tolerant operation of Micro-Grids
2010
The progressive penetration level of Distributed Generation (DG) is destined to cause deep changes in the existing distribution networks no longer considered as passive terminations of the whole electrical system. A possible solution is the realization of small networks, namely the Micro-Grids, reproducing in themselves the structure of the main production and distribution of the electrical energy system. In order to gain an adequate reliability level of the microgrids the individuation and the management of the faults with the goal of maintaining the micro-grid operation (fault tolerant operation) is quite important. In the present paper flexible power converters and a companion control al…
Closed-loop bandwidth impact on MVSA for rotor broken bar diagnosis in IRFOC double squirrel cage induction motor drives
2013
This paper investigates the detectability of rotor broken bars in indirect rotor flux oriented control (IRFOC) for variable speed double cage induction motor drives, using vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of rotor asymmetries in the machine is based on the signature analysis of electrical or mechanical variables. Therefore, the investigation of rotor fault components for different bandwidths of closed-loop regulators is necessary to evaluate its relevance in the above listed variables. This paper investigates the impact of the control system on relevance of the fault components computed from axial an…
Food Tray Sealing Fault Detection in Multi-Spectral Images Using Data Fusion and Deep Learning Techniques
2021
A correct food tray sealing is required to preserve food properties and safety for consumers. Traditional food packaging inspections are made by human operators to detect seal defects. Recent advances in the field of food inspection have been related to the use of hyperspectral imaging technology and automated vision-based inspection systems. A deep learning-based approach for food tray sealing fault detection using hyperspectral images is described. Several pixel-based image fusion methods are proposed to obtain 2D images from the 3D hyperspectral image datacube, which feeds the deep learning (DL) algorithms. Instead of considering all spectral bands in region of interest around a contamin…
Nature and origin of fault-controlled fluid seepage across the Maltese Islands
2018
The Maltese Islands are intersected by two major fault systems associated with two diverse rifting episodes affect the islands. The first and most widespread system is Early Miocene to mid-Pliocene in age, and consists of faults that are orientated ENE-WSW. The most distinct of these faults is the Great Fault (known also as the Victoria Lines Fault). The younger system of faults (Late Miocene-Early Pliocene) is still active and consists of faults striking NW to SE that often cross-cut the first generation of faults. The most extensive of these faults is the Maghlaq Fault, located along the southern coastline of the Maltese Islands.
FUZZY RISK ANALYSIS OF A MODERN γ-RAY INDUSTRIAL IRRADIATOR
2011
Fuzzy fault tree analyses were used to investigate accident scenarios that involve radiological exposure to operators working in industrial γ-ray irradiation facilities. The HEART method, a first generation human reliability analysis method, was used to evaluate the probability of adverse human error in these analyses. This technique was modified on the basis of fuzzy set theory to more directly take into account the uncertainties in the error-promoting factors on which the methodology is based. Moreover, with regard to some identified accident scenarios, fuzzy radiological exposure risk, expressed in terms of potential annual death, was evaluated. The calculated fuzzy risks for the examine…
Can Signaling Theory Help Agency and Resource Scarcity Theories Explain Franchisee Failure? Predicting SBA-Backed Loan Defaults
2010
This study examines the use of analytic techniques to develop a model that predicts the potential default of Small Business Administration (SBA) backed loans issued to American franchisees. Data collected by World Franchising (WF) in their 2008 survey and by SBA from 2000-2008, covering 271 diverse US franchise chains, on the reported failure rates and charge off percentages of SBA backed loans was used to explore associations between franchisor characteristics and franchisee loan performances. The predictive capability of the derived model was assessed using a data mining technique in which the original data set is split into two different subsets: one for estimation and one for validation…
Design of an exact data deduplication cluster
2012
Data deduplication is an important component of enterprise storage environments. The throughput and capacity limitations of single node solutions have led to the development of clustered deduplication systems. Most implemented clustered inline solutions are trading deduplication ratio versus performance and are willing to miss opportunities to detect redundant data, which a single node system would detect. We present an inline deduplication cluster with a joint distributed chunk index, which is able to detect as much redundancy as a single node solution. The use of locality and load balancing paradigms enables the nodes to minimize information exchange. Therefore, we are able to show that, …
A fault-tolerant protocol for railway control systems
2006
Railway control systems are largely based on data communication and network technologies. With the adoption of Ethernet-IP as the main technology for building end-to-end real-time networks on railway control systems, the requirement to deliver high availability, quality and secure services over Ethernet has become strategic. Critical real-time traffic is generally penalized and the maximum restoration time of 50 msec sometimes is exceeded because of real-time applications hangings, so passengers' safety could be committed. It occurs on more than twenty percent of critical fail tests performed. Our main goal is to minimize restoration time from the application point of view. This article des…