Search results for "fluid"
showing 10 items of 5513 documents
Modification of Angular Kinematics and Spatiotemporal Parameters during Running after Central and Peripheral Fatigue
2021
Fatigue causes kinematics modifications during running, and it could be related to injuries. The aim was to identify and compare the effects of central and peripheral fatigue on angular kinematics and spatiotemporal parameters during running. Angular kinematics and spatiotemporal parameters were evaluated using an infrared motion capture system and were registered during 2 min treadmill running in pre- and post-fatigue states in eighteen male recreational runners. Central fatigue was induced by a 30 min running fatigue protocol on a treadmill, while peripheral fatigue in quadriceps and hamstrings muscles was induced by an isokinetic dynamometer fatigue protocol. Central fatigue increased th…
Influence of artificial blood contamination of the analysis of cerebrospinal fluid
1981
The influence of artificial blood contamination on the quantitative values obtained in the routine examination of the CSF was investigated. On the basis of dilution series from CSF and blood, the correlation between the number of added erythrocytes and the results of leukocyte counts, protein, glucose and IgG estimation was studied. In addition, the influence of the time between CSF sampling and investigation on erythrocytes and leukocytes, IgG, glucose, pH value and ammonia content in CSF contaminated with blood was investigated. The following data relevant to routine examinations resulted: there are linear correlations between the number of erythrocytes artificially added to the CSF and t…
Ultrasound observation of tissue fluid infiltration causing stridor in a woman undergoing shoulder arthroscopy
2012
Respiratory stridor developed rapidly during an interscalene brachial plexus block for shoulder arthroscopy in an obese woman. Extensive cervicothoracic edema due to tissue diffusion of the arthroscopic fluid was suspected. The outcome of patient after conservative management was satisfactory. We give a brief review of how this complication develops, the ultrasound findings, and briefly discuss similar cases.
Transverse Sinus Stenosis in Refractory Chronic Headache Patients: An Observational Study
2019
Background: Transverse sinus stenosis is a common brain MRI finding in chronic migraine (CM) and chronic tension-type headache (CTTH) patients in clinical practice; however, its clinical and diagnostic role is unclear. The aim of the study is to determine the frequency of transverse sinus stenosis in these headache patients resistant to preventive treatments and to verify whether this is a useful finding for identifying patients with intracranial hypertension. Methods: This is an observational study. Patients with refractory CM and CTTH underwent a 3T-magnetic resonance venography (MRV) before cerebrospinal fluid (CSF) opening pressure measurement. Transverse sinus stenosis was determined u…
High-resolution images in macular disorders
2021
Objective: This study analyzed and compared the results of adaptive optics (AO) and fundus autofluorescence (FAF) in various maculopathies. Methods: The study included four different types of maculopathy: central serous chorioretinopathy (CSC), retinitis pigmentosa (RP), Stargardt disease (STGD) and phototoxic retinopathy. In all four cases, cone mosaic and cone density were obtained using AO fundus camera. Further, the high-resolution images were compared with the FAF and optical coherence tomography (OCT) results. Results: In CSC, FAF and AO, changes could be shown in the macula even two years after the subretinal fluid resorption, as opposed to a normal OCT. The improvement of FAF and co…
Electrohysterogram Signals from Patients with Threatened Preterm Labor: Concentric Ring Electrode Vs Disk Electrode Recordings
2017
Vascular atherosclerotic disease: evaluation of the whole-blood filterability and red cell membrane microrheological pattern after intravenous admini…
1990
SummaryA study was carried out in 10 patients with vascular atherosclerotic disease to investigate the effects of a single dose of 300 mg pentoxifylline, given by intravenous infusion over 30 minutes, on various macrorheological and nzicrorheological parameters. Measurements were made at baseline, at the end of the intravenous infusion and again 30 minutes later of whole-blood filterability, erythrocyte membrane fluidity (using pyrene as probe) and transverse fluidity gradient (using fluorescent fatty acids as probes). The results showed that there was a significant variation in whole-blood filterability and the red cell membrane fluidity gradient after pentoxifylline. No difference, howeve…
Letter: Cerebrospinal Fluid Shunting Improves Long-Term Quality of Life in Idiopathic Normal Pressure Hydrocephalus.
2020
Chorioretinopathia serosa centralis (CSC) und Kortikosteroide
2008
Background Corticosteroids are under suspicion of playing an important role in the development of central serous chorioretinopathy (CSC). Patients and methods In a prospective study the course of CSC was evaluated in a consecutive series of 46 patients, who received the diagnosis of CSC in the period 4 / 2004 - 12 / 2005. Data analysis was focused on the complete medical and ocular history and the ocular course of this disease. Results 27 patients had been taking exogenous corticosteroids (oral, intravenous, inhalative, cutaneous and intraarticular) within 4 weeks before onset of symptoms. Additionally, one case with Cushing's disease and 2 pregnant women were included. These 30 / 46 patien…
Alteration of Heart Rate Variability as an Early Predictor of Cardiovascular Events: A Look at Current Evidence
2020
Evidence suggests an association between autonomic nervous system (ANS) function and atrial fibrillation (AF) development. We sought to examine the association of baseline resting heart rate (RHR) and short-term heart rate variability (HRV) as surrogates of (ANS) with incident AF in individuals without prior cardiovascular disease. A total of 6261 participants of the Multi Ethnic Study of Atherosclerosis (MESA) who were free of AF and diagnosed cardiovascular disease were enrolled. Three standard 10-second, 12-lead electrocardiograms were used to measure RHR, the standard deviation of normal-to-normal intervals (SDNN) and the root mean square of successive differences in RR intervals (RMSSD…