Search results for "monitor"
showing 10 items of 3841 documents
Can saliva offer an advantage in monitoring of diabetes mellitus? - A case control study
2014
Objectives: Diabetes Mellitus is emerging as a major health problem over these years. Present method of blood glucose monitoring by venepuncture is invasive leading to reduced patient compliance and thereby ineffective judicious monitoring. The need of the hour is to direct research in the direction of establishing painless and more acceptable blood glucose analysis method.The objective of the study is to conduct a comparative analysis of the concentrations of salivary glucose and blood glucose in type 2 diabetes mellitus patients. Study Design: This study assessed glucose levels using the glucose oxidase method in blood and unstimulated sali - va in 90 subjects who were divided into 3 equa…
Home blood pressure control is low during the critical morning hours in patients with hypertension: the SURGE observational study
2011
Background. The morning blood pressure (BP) surge is associated with a peak increase in vascular events. Objective. The aim of this observational study was to evaluate morning BP control in treated hypertensive patients using home BP (HBP) monitoring and to compare these findings with clinic BP control. Methods. Clinic BP was measured twice during a 2-week period, prior to medication. Seated HBP was measured, using a BHS-validated device, three times per day over a 2-week period. Assessments included morning (06:00–11:59), lunchtime (12:00–14:00) and evening (18:00–22:00) HBP control (all <135/85 mmHg) and clinic BP (<140/90 mmHg) control. Results. A total of 15 618 patients were assessed. …
Blood Pressure control by 24-hour Ambulatory Monitoring in Chronic Renal Failure.
2005
Self-blood pressure monitoring as a tool to increase hypertension awareness, adherence to antihypertensive therapy, and blood pressure control
2019
For many years, casual blood pressure (BP) taken by a sphygmomanometer in the clinic or at the physician's office has been used as the standard method for diagnosing hypertension. Even if such measurement has been the cornerstone on which our understanding of the consequences of hypertension is based, there is a huge and very consistent body of evidence indicating that casual measurements of BP may provide a very unreliable index for the evaluation of hypertension because of their variability. The two alternative ways of measuring BP that have been most commonly used are measurements made at home by the patient himself (home or self‐BP monitoring—SBPM) and measurements by ambulatory blood p…
Prognostic Value of Ambulatory Blood Pressure Monitoring in Refractory Hypertension : A Prospective Study
1998
The objective of this study was to establish whether ambulatory blood pressure offers a better estimate of cardiovascular risk than does its clinical blood pressure counterpart in refractory hypertension. This prospective study assessed the incidence of cardiovascular events over time during an average follow-up of 49 months (range, 6 to 96). Patients were referred to specialized hypertension clinics (86 essential hypertension patients who had diastolic blood pressure >100 mm Hg during antihypertensive treatment that included three or more antihypertensive drugs, one being a diuretic). Twenty-four-hour ambulatory blood pressure monitoring (ABPM) was performed at the time of entrance. End-or…
Factores que influyen en la diferencia de medida de presión arterial entre el método auscultatorio y el oscilométrico
2006
Fundamento y objetivo El metodo auscultatorio mediante esfigmomanometro de mercurio esta siendo sustituido por otros metodos de medida de presion arterial, de los que el mas utilizado es el oscilometrico. Se analiza las posibles discrepancias de medida entre ambos metodos y los factores que influyen en ellas. Material y metodo Se obtuvieron medidas de presion arterial (PA) mediante esfigmomanometro de mercurio, con un monitor Spacelabs, en el mismo brazo y mediante un metodo secuencial. La relacion entre ambas medidas se analizo mediante los coeficientes de correlacion de Pearson y el metodo de Bland y Altman. Se calcularon las diferencias entre ambos metodos de medida. Se analizo los facto…
RELATIONSHIPS BETWEEN SHORT-TERM BLOOD PRESSURE VARIABILITY AND EARLY RENAL DYSFUNCTION IN ESSENTIAL HYPERTENSIVE PATIENTS
2014
Should reduction of increased short‐term blood pressure variability be a target of antihypertensive therapy?
2021
Abstract It has long been known that blood pressure (BP) is characterized by marked short‐term fluctuations occurring within a 24‐h period and also by long‐term oscillations occurring over more prolonged periods of time. An increased short‐term blood pressure variability (BPV) appears to importantly contribute to target organ damage and to the enhanced cardiovascular risk of hypertensive patients, over and above the effect of an increase in mean BP levels. Reducing 24‐h mean BP is the main aim of antihypertensive therapy, but initial data are available that additional cardiovascular protection can be achieved by reducing BPV. However, to definitively prove the prognostic role of short‐term …
ABSENCE OF RELATIONSHIPS BETWEEN SHORT-TERM BLOOD PRESSURE VARIABILITY AND EARLY RENAL DYSFUNCTION IN HYPERTENSION
2014
Blood pressure variability
Photoplethysmography system for blood pulsation detection in unloaded artery conditions
2012
Photoplethysmography (PPG) is an optical method of blood pulsation recording and has been extensively studied for decades. Recently PPG is widely used in the medical equipment for patient monitoring and in laboratories for research and physiological studies. In spite of the technological progress in the field of medical equipment, there are no generally accepted standards for clinical PPG measurements up to date. One of the most important factors affecting PPG waveform is the contact pressure between tissue and PPG probe. The aim of the current study was to develop and evaluate a system for software-assisted PPG signal acquisition from the unloaded artery. Novel PPG waveform derived Optimal…