Search results for "optics"
showing 10 items of 10033 documents
Increasing the Astrophysical Reach of the Advanced Virgo Detector via the Application of Squeezed Vacuum States of Light
2019
Current interferometric gravitational-wave detectors are limited by quantum noise over a wide range of their measurement bandwidth. One method to overcome the quantum limit is the injection of squeezed vacuum states of light into the interferometer's dark port. Here, we report on the successful application of this quantum technology to improve the shot noise limited sensitivity of the Advanced Virgo gravitational-wave detector. A sensitivity enhancement of up to 3.2±0.1 dB beyond the shot noise limit is achieved. This nonclassical improvement corresponds to a 5%-8% increase of the binary neutron star horizon. The squeezing injection was fully automated and over the first 5 months of the thi…
Thermal noise limit for ultra-high vacuum noncontact atomic force microscopy
2013
The noise of the frequency-shift signal Δf in noncontact atomic force microscopy (NC-AFM) consists of cantilever thermal noise, tip–surface-interaction noise and instrumental noise from the detection and signal processing systems. We investigate how the displacement-noise spectral density dz at the input of the frequency demodulator propagates to the frequency-shift-noise spectral density dΔf at the demodulator output in dependence of cantilever properties and settings of the signal processing electronics in the limit of a negligible tip–surface interaction and a measurement under ultrahigh-vacuum conditions. For a quantification of the noise figures, we calibrate the cantilever displacemen…
Noiseless Quantum Measurement and Squeezing of Microwave Fields Utilizing Mechanical Vibrations
2017
A process which strongly amplifies both quadrature amplitudes of an oscillatory signal necessarily adds noise. Alternatively, if the information in one quadrature is lost in phase-sensitive amplification, it is possible to completely reconstruct the other quadrature. Here we demonstrate such a nearly perfect phase-sensitive measurement using a cavity optomechanical scheme, characterized by an extremely small noise less than 0.2 quanta. We also observe microwave radiation strongly squeezed by 8 dB below vacuum. A source of bright squeezed microwaves opens up applications in manipulations of quantum systems, and noiseless amplification can be used even at modest cryogenic temperatures.
Modification of a commercial atomic force microscopy for low-noise, high-resolution frequency-modulation imaging in liquid environment.
2011
A key issue for high-resolution frequency-modulation atomic force microscopy imaging in liquids is minimizing the frequency noise, which requires a detailed analysis of the corresponding noise contributions. In this paper, we present a detailed description for modifying a commercial atomic force microscope (Bruker MultiMode V with Nanoscope V controller), aiming at atomic-resolution frequency-modulation imaging in ambient and in liquid environment. Care was taken to maintain the AFMs original stability and ease of operation. The new system builds upon an optimized light source, a new photodiode and an entirely new amplifier. Moreover, we introduce a home-built liquid cell and sample holder …
Experimental on-demand recovery of entanglement by local operations within non-Markovian dynamics
2015
In many applications entanglement must be distributed through noisy communication channels that unavoidably degrade it. Entanglement cannot be generated by local operations and classical communication (LOCC), implying that once it has been distributed it is not possible to recreate it by LOCC. Recovery of entanglement by purely local control is however not forbidden in the presence of non-Markovian dynamics, and here we demonstrate in two all-optical experiments that such entanglement restoration can even be achieved on-demand. First, we implement an open-loop control scheme based on a purely local operation, without acquiring any information on the environment; then, we use a closed-loop s…
Coherence in ultrashort light pulses and applications in temporal optics.
2008
In the last decades, the generation of lasers delivering pulses with durations in the order of femtosecond has constituted an important research topic for the Physics and Engineering communities. The characteristics of this kind of radiation, i.e., broadband spectrum, enormous temporal resolution, high peak-power with low energy average, potentially high repetition rate and high spatial coherence make it an indispensable tool in order to develop many applications in different fields of science and technology. Ultrafast laser technology is ready to offer real world applications ranging from high-tech, such us high-speed circuit testing and biological imaging, to more industrial applications …
Exact Reconstruction of Sub-wavelength THz Source Profile via Combination of Knife-edge Technique and Time-domain Spectroscopy
2013
Recent experiments at the JYFLTRAP Penning trap
2020
AbstractThe JYFLTRAP double Penning trap mass spectrometer at the Ion Guide Isotope Separator On-Line (IGISOL) facility offers excellent possibilities for high-precision mass measurements of radioactive ions. Around 400 atomic masses, including around 50 isomeric states, have been measured since JYFLTRAP became operational. JYFLTRAP has also been used as a high-resolution mass separator for decay spectroscopy experiments as well as an ion counter for fission yield studies. In this contribution, an overview of recent activities at the JYFLTRAP Penning trap is given, with a focus on nuclei discussed in the PLATAN2019 meeting.
The Gaia-ESO Survey: The inner disk, intermediate-age open cluster Trumpler 23
2017
Full list of authors: Overbeek, J. C.; Friel, E. D.; Donati, P.; Smiljanic, R.; Jacobson, H. R.; Hatzidimitriou, D.; Held, E. V.; Magrini, L.; Bragaglia, A.; Randich, S.; Vallenari, A.; Cantat-Gaudin, T.; Tautvaišienė, G.; Jiménez-Esteban, F.; Frasca, A.; Geisler, D.; Villanova, S.; Tang, B.; Muñoz, C.; Marconi, G. Carraro, G.; San Roman, I.; Drazdauskas, A.; Ženovienė, R.; Gilmore, G.; Jeffries, R. D.; Flaccomio, E.; Pancino, E.; Bayo, A.; Costado, M. T.; Damiani, F.; Jofré, P.; Monaco, L.; Prisinzano, L.; Sousa, S. G.; Zaggia, S.
Negative and positive Kerr nonlinearity of air calibrated with transient molecular alignment
2009
Talk given by O. Faucher; International audience; Nonlinear electronic Kerr index of the major air constituents has been measured up to high order terms using transient molecular alignment as a reference. Sign reversal associated to negative nonlinearity is observed above a pulse intensity of 26 TW/cm^.2