Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering
2013
Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …
Effect of phenylephrine on static and dynamic accommodation
2018
Purpose We tested the hypothesis that changes in accommodation after instillation of Phenylephrine Hydrochloride (PHCl) observed in some studies could be caused by changes in optics. Methods We performed two experiments to test the effects of PHCl on static and on dynamic accommodation in 8 and 6 subjects, respectively. Objective wavefront measurements were recorded of the static accommodation response to a stimulus at different distances or dynamic accommodation response to a sinusoidally moving stimulus (between 1 and 3 D of accommodative demand at 0.2 Hz). The responses were characterized using two methods: one that takes into account the mydriatic optical effects on the accommodation pr…
On-eye optical quality of daily disposable contact lenses for different wearing times
2012
Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…
The synthetic cannabinoid 5F-MDMB-PICA: A case series
2020
5F-MDMB-PICA has been detected in products sold on the internet as well as in biological samples since 2016. It is associated with serious adverse health and behavioral effects and even death. Herein we report on twelve cases with proven 5F-MDMB-PICA consumption, including three fatalities, four cases of driving under the influence of drugs and five other criminal acts. In these cases, 5F-MDMB-PICA was detected in postmortem blood or serum. Concentrations ranged from 0.1-16ng/mL. In some blood (serum) and urine samples, the hydrolysis metabolite of 5F-MDMB-PICA (M12) could also be detected. In this case series, co-consumption with other drugs occurred in 9 of 12 cases, most commonly alcohol…
Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool
2021
Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …
Changes in accommodative responses with multifocal contact lenses: a pilot study.
2011
Our aim was to evaluate induced changes in pupil and accommodative response for different accommodative stimuli with three different multifocal contact lenses (CLs). Accommodative and pupil responses with three aspheric multifocal CLs of simultaneous focus center near (PureVision Low Add, PureVision High Add and Focus Progressives) for two accommodative stimuli of -2.5 and -4.00 D were recorded in 10 young subjects. Accommodative response, peak velocity, and time constant of accommodation and pupil constriction were assessed. The measurements were evaluated in all the participants with distance-single vision CLs and with the three multifocal CLs. The monocular measurements were performed in…
Optical quality in eyes with aspheric intraocular lenses and in younger and older adult phakic eyes: comparative study.
2009
To compare ocular higher-order aberrations (HOAs) in eyes with aspheric intraocular lenses (IOL) and in phakic eyes.Department of Ophthalmology, Military Health Service Institute, Warsaw, Poland.Higher-order aberrations with a 5.0 mm pupil and best spectacle-corrected visual acuity (BSCVA) were analyzed in a young phakic group (age 20 to 40 years), older phakic group (age 40 to 60 years), and a pseudophakic group (age 62 to 84 years; SN60WF aspheric IOL).The mean coma was 0.13 microm+/-0.07 (SD) in the younger phakic group, 0.18+/-0.08 microm in the older phakic group, and 0.16+/-0.08 microm in the pseudophakic group; the difference between the 2 phakic groups was statistically significant …
Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system
2014
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…
How Do Different Digital Displays Affect the Ocular Surface?
2020
Digital display use has been accepted as a contributing factor to dry eye disease. Nowadays, plenty of new models of digital displays have been developed, and the differences in their nature and the ways in which they are set and used may contribute to differences in the eye-related problems they cause.This study aimed to analyze the differences in ocular surface, tear film, and visual fatigue parameters after reading on different digital displays, with and without initial instillation of artificial tears.Thirty-one healthy individuals ranging in age from 20 to 26 years (mean ± standard deviation, 21.26 ± 1.73 years) were included in this prospective clinical study. Subjects' ocular surface…