Search results for "resolution"

showing 10 items of 1928 documents

Continuously Variable Periodic Test Target

1987

CONTINUOUSLY VARIABLE PERIODIC TEST TARGETP. ANDRES*, J. OJEDA- CASTANEDAt, and J.C. BARREIRO*tINAOE, Apartado Postal 216, 72000 Puebla, Pue., Mexico*Departamento de Optica, Universidad de Valencia, 46100 Burjasot, Spain1. INTRODUCTIONThe modulus of the optical transfer function (MTF) of the eye or any other optical system is usuallyevaluated by imaging either several gratings each with different spatial frequency, or a single test tar-get having patterns with different frequencies (USAF resolution chart). In any of these two usual proce-dures, the measurement of the MTF is made at discrete values of the spatial frequency.Here we describe a method based on the self -imaging phenomenon for p…

PhysicsOptical axisOpticsbusiness.industryOptical transfer functionTalbot effectImage processingSpatial frequencyMonochromatic colorGratingbusinessImage resolutionSPIE Proceedings
researchProduct

Diffractive optics for high-resolution low-coherence digital holography

2010

We study the properties of the recording of off-axis holograms when a 10 fs pulsed laser is used as illumination source. A proper optical design involving one diffractive lens outside a Michelson interferometer enables the recording of full-field off-axis holograms with high resolution and optical sectioning. We demonstrate our approach with some experimental results that show optical sectioning with a maximum resolution of 3.5 µm. We note that the axial resolution of the technique is reduced up to 9 µm when the object beam travels through a few millimeters of glass due to the pulse broadening along dispersive media.

PhysicsOptical sectioningbusiness.industryHolographyPhysics::OpticsMichelson interferometerHolographic interferometrylaw.inventionInterferometryOpticslawOptoelectronicsbusinessImage resolutionDigital holographyCoherence (physics)2010 9th Euro-American Workshop on Information Optics
researchProduct

High resolution study of the 3ν1 band of SO2

2009

Abstract The second overtone band 3 ν 1 of sulfur dioxide has been studied for the first time with high resolution rotation-vibration spectroscopy. About 3000 transitions involving about 900 upper state energy levels with J max. = 66 and K a max. = 24 have been assigned to the 3 ν 1 band. In the analysis, an effective Hamiltonian taking into account accidental interactions between the vibrational states (3 0 0), (2 2 0), and (0 4 1) was used. The Watson operator in A -reduction and I r representation was used in the diagonal blocks of the Hamiltonian. As the result of analysis a set of parameters reproducing the initial experimental data with the rms = 0.00028 cm −1 was obtained.

PhysicsOvertoneDiagonalHigh resolutionAtomic and Molecular Physics and Opticssymbols.namesakeNuclear magnetic resonancesymbolsHigh resolution spectraPhysical and Theoretical ChemistryAtomic physicsSpectroscopyHamiltonian (quantum mechanics)SpectroscopyJournal of Molecular Spectroscopy
researchProduct

Resistive Micromegas for the Muon Spectrometer Upgrade of the ATLAS Experiment

2017

It is reported on the construction and test of large scale resistive Micromegas detectors for the ATLAS New Small Wheel upgrade. The production procedure of the 2 to 3 m2 active area is described. The validation of the construction procedure is proven with results obtained with prototype detectors showing 100 µm spatial resolution in the precision coordinate and above 98% efficiency In the context of the upgrade project of the ATLAS Muon system, we report on the construction of Micromegas detectors with an active area of 2 to 3 m$^2$ . The validation of the construction procedure is proven with results obtained with prototype detectors showing 100 $\mu $m spatial resolution in the precision…

PhysicsParticle physicsMuonPhysics::Instrumentation and DetectorsATLAS experimentDetectorContext (language use)MicroMegas detectorNuclear physicsmedicine.anatomical_structureUpgradeAtlas (anatomy)medicineHigh Energy Physics::ExperimentImage resolutionParticle Physics - Experiment
researchProduct

Magnetization changes visualized using photoemission electron microscopy

2004

Abstract Photoemission electron microscopy was used to visualize the motion of magnetic domains on a sub-nanosecond timescale. The technique exploits the imaging of magnetic domains using soft X-ray circular dichroism, with the special feature that the instrument utilizes a fast image acquisition system with intrinsic 125 ps time resolution. The overall time resolution used is about 500 ps. Different domains and domain movements have been observed in lithographically-produced Permalloy structures on a copper microstrip-line. A current pulse of I=0.5 A with rise times of about 300 ps switched the Permalloy islands from a Landau-Lifshitz type domain configuration into metastable s-state domai…

PhysicsPermalloyMagnetization dynamicsRadiationCondensed matter physicsMagnetic domainMagnetismResolution (electron density)Condensed Matter PhysicsAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsMagnetizationPhotoemission electron microscopyNuclear magnetic resonanceMicroscopyPhysical and Theoretical ChemistrySpectroscopyJournal of Electron Spectroscopy and Related Phenomena
researchProduct

Stroboscopic XMCD-PEEM Imaging

2007

Abstract This article summarizes recent results on magnetization dynamics obtained with time-resolved photoemission electron microscopy (PEEM) using X-ray magnetic circular dichroism as contrast mechanism. Time resolution is performed by a stroboscopic technique that is exclusively sensitive to reversible processes, but offers a very high time resolution only limited by the X-ray pulse width. A time resolution of 20 ps in combination with a lateral resolution of 100 nm has been achieved.

PhysicsPhotoemission electron microscopyMagnetization dynamicsOpticsNuclear magnetic resonanceX-ray magnetic circular dichroismMagnetic circular dichroismbusiness.industryTime resolutionLateral resolutionbusinessStroboscope
researchProduct

DOI measurement with monolithic scintillation crystals: A primary performance evaluation

2007

We report a first assessment of image quality enhancement achieved by the implementation of depth of interaction detection with monolithic crystals. The method of interaction depth measurement is based on analogue computation of the standard deviation with an enhanced charge divider readout. This technique of depth of interaction detection was developed in order to provide fast and determination of this parameter at a reasonable increase of detector cost. The detector consists of an large-sized monolithic scintillator coupled to a position sensitive photomultiplier tube. A special design feature is the flat-topped pyramidal shape of the crystal. This reduces image compression near the edges…

PhysicsPhotomultiplierOpticsPhysics::Instrumentation and DetectorsImage qualityPoint sourcebusiness.industryMeasured depthDetectorScintillatorbusinessImage resolutionImaging phantom2007 IEEE Nuclear Science Symposium Conference Record
researchProduct

2021

Abstract IceCube is a cubic-kilometer Cherenkov telescope operating at the South Pole. The main goal of IceCube is the detection of astrophysical neutrinos and the identification of their sources. High-energy muon neutrinos are observed via the secondary muons produced in charge current interactions with nuclei in the ice. Currently, the best performing muon track directional reconstruction is based on a maximum likelihood method using the arrival time distribution of Cherenkov photons registered by the experiment's photomultipliers. A known systematic shortcoming of the prevailing method is to assume a continuous energy loss along the muon track. However at energies >1 TeV the light yie…

PhysicsPhotomultiplierPhotonMuonPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for Astrophysics7. Clean energy01 natural scienceslaw.inventionNuclear physicsTelescopelaw0103 physical sciencesHigh Energy Physics::ExperimentAngular resolutionNeutrino010306 general physics010303 astronomy & astrophysicsInstrumentationParametrizationMathematical PhysicsCherenkov radiationJournal of Instrumentation
researchProduct

Resolution changes of MCP-PMTs in magnetic fields

2016

Micro-channel plate photomultiplier tubes (MCP-PMTs) are chosen in many applications that have to cope with strong magnetic fields. The DIRC detectors of the PANDA experiment plan to employ them as they show excellent timing characteristics, radiation hardness, relatively low dark count rates and sufficient lifetime. This article mainly focuses on the performance of the position reconstruction of detected photons. Two different MCP-PMTs with segmented anode geometries have been tested in magnetic fields of different strengths. The variation of their performance has been studied. The measurements show improved position resolution and image shifts with increasing magnetic field strength.

PhysicsPhotomultiplierPhotonPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industryDetectorResolution (electron density)Electrical engineering01 natural sciences030218 nuclear medicine & medical imagingMagnetic fieldAnode03 medical and health sciences0302 clinical medicineOpticsPosition (vector)0103 physical sciencesbusinessInstrumentationRadiation hardeningMathematical PhysicsJournal of Instrumentation
researchProduct

Angular resolution of an array of tracking-chamber detectors for use in high-energy gamma-ray astronomy

1992

We describe a method of analysis for the reconstruction of the arrival direction of a high-energy photon impacting on the top of the atmosphere by using the directions of the particles on the shower front as measured by a ground-based array of tracking chambers uniformly distributed on a square surface; as an example, an array with enclosed surface of (120×120) m2 has been considered. Estimates on the accuracy of reconstruction are given, after application of the method to computer-simulated shower directions as a function of the number of «smapling» detectors and of their accuracy in the measurement of the «local» shower direction.

PhysicsPhotonOpticsPhysics::Instrumentation and Detectorsbusiness.industryDetectorScintillation counterCosmic rayAngular resolutionGamma-ray astronomyTracking (particle physics)businessSquare (algebra)Il Nuovo Cimento C
researchProduct