0000000000013893
AUTHOR
Harald Becher
Comparison of Sulfur Hexafluoride Microbubble (SonoVue)-Enhanced Myocardial Contrast Echocardiography With Gated Single-Photon Emission Computed Tomography for Detection of Significant Coronary Artery Disease
Objectives The purpose of this study was to compare sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography (MCE) with single-photon emission computed tomography (SPECT) relative to coronary angiography (CA) for assessment of coronary artery disease (CAD). Background Small-scale studies have shown that myocardial perfusion assessed by SonoVue-enhanced MCE is a viable alternative to SPECT for CAD assessment. However, large multicenter studies are lacking. Methods Patients referred for myocardial ischemia testing at 34 centers underwent rest/vasodilator SonoVue-enhanced flash-replenishment MCE, standard Tc-99m-labeled electrocardiography-gated SPECT, and quanti…
Analysis of myocardial perfusion or myocardial function for detection of regional myocardial abnormalities. An echocardiographic multicenter comparison study using myocardial contrast echocardiography and 2D echocardiography.
Background: Echocardiography based myocardial perfusion imaging and regional wall motion analysis are used for evaluation of coronary artery disease and regional myocardial abnormalities. Aim: This study sought to compare myocardial contrast echocardiography (MCE) and 2D echocardiography with regard to interobserver variability and detection of regional myocardial abnormalities. Methods: In 70 patients evenly distributed between three ejection fraction groups based on biplane cineventriculography (>55%, 35-55%, <35%), unenhanced and contrast enhanced 2D echocardiography and myocardial contrast echocardiography (MCE; SonoVue (R); Bracco) were performed. Regional watt motion and myocardial pe…
Analysis of Regional Left Ventricular Function by Cineventriculography, Cardiac Magnetic Resonance Imaging, and Unenhanced and Contrast-Enhanced Echocardiography
OBJECTIVES To define the use of cineventriculography, cardiac magnetic resonance imaging (cMRI), and unenhanced and contrast-enhanced echocardiography for detection of left ventricular (LV) regional wall motion abnormalities (RWMA). BACKGROUND Detection of RWMA is integral to the evaluation of LV function. METHODS In 100 patients, cineventriculography and unenhanced and contrast-enhanced echocardiography were performed. Fifty-six of the patients underwent additional cMRI. RWMA were assessed referring to a 16-segment model for cMRI, unenhanced and contrast echocardiography. Cineventriculography was evaluated on a 7-segment model. Hypokinesia in one or more segments defined presence of RWMA. …
Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhanced and contrast-enhanced two-dimensional and three-dimensional echocardiography.
Background: Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV)functional analyses inthe settingof two-dimensional (2D) echocardiography. Theneedfor contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography for the assessment of LV volumes and ejection fraction (EF). Methods: A multicenter, open-label study was conducted including 63 patients, using intrasubject comparisons to assess the agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography as well as…
Comparison of Two- and Three-Dimensional Unenhanced and Contrast-Enhanced Echocardiographies Versus Cineventriculography Versus Cardiac Magnetic Resonance for Determination of Left Ventricular Function
Contrast enhancement has been shown to improve detection of regional wall motion abnormalities (RWMA) in 2-dimensional (2D) echocardiography. This study determined the use of contrast enhancement in the setting of 3-dimensional (3D) echocardiography for definition of left ventricular RWMA compared with 2D echocardiography, cineventriculography, and cardiac magnetic resonance (CMR). In 63 patients, unenhanced and contrast-enhanced (SonoVue; Bracco Imaging S.p.A., Milan, Italy) 2D and 3D echocardiographies, CMR, and cineventriculography were performed. Hypokinesia in ≥1 segment defined the presence of RWMA. Interreader agreement (IRA) between 2 blinded off-site readers on presence of RWMA was…
The use of contrast echocardiography: a matter of clinical judgement
In their editorial, Buck and Erbel1 raise the important question in which settings application of contrast agents to an echocardiographic examination is appropriate. There is no doubt that the beauty of echocardiography relates to its ease of use. We should acknowledge that highest accuracy in the determination of left ventricular function is not necessary in most patients referred for an echocardiographic evaluation. Thus, contrast echocardiography will not be a technique to be used in all patients for mere evaluation of left ventricular function as cardiac magnetic resonance imaging will not be used in routine clinical practice only for its known superb accuracy. However, there are patien…
Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography
Aims To assess the agreement of left ventricular ejection fraction (LVEF) determinations from unenhanced echocardiography, contrast-enhanced echocardiography, magnetic resonance imaging (MRI), and cineventriculography as well as the inter-observer agreement for each method. Methods and results In 120 patients, with evenly distributed EF-groups (G 55, 35-55, L 35%), cineventriculography, unenhanced echocardiography with second harmonic imaging, and contrast echocardiography at tow mechanical index with iv administration of SonoVueR were performed. In addition, cardiac MRI at 1.5T using a steady-state free precession sequence was performed in a subset of 55 patients. On-site, and two blinded …