0000000000014687

AUTHOR

B. Morlon

showing 10 related works from this author

Viscosity of the elbow flexor muscles during maximal eccentric and concentric actions.

1996

The aim of the present study was to estimate the damping coefficient (B factor) of the elbow flexor muscles during both eccentric and concentric muscle actions. We used a muscle model consisting of a viscous damper associated in parallel with a contractile component, both in series with an elastic component. The viscous damper allowed the concentric loss and the eccentric gain of force to be modelled. Eight volunteer subjects performed maximal eccentric and concentric elbow movements on an isokinetic dynamometer at angular velocities of 0.52, 1.04 and 2.09 rad*s(-1). Torques at an elbow joint angle of 90 degrees were recorded. Electromyogram (EMG) signals from the belly of the right elbow f…

AdultMalePhysiologyElbowElectromyographyConcentricModels BiologicalPhysiology (medical)medicineElbowEccentricHumansOrthopedics and Sports MedicinePhysicsmedicine.diagnostic_testTension (physics)ElectromyographyViscosityMusclesPublic Health Environmental and Occupational HealthBiomechanicsGeneral MedicineAnatomymedicine.anatomical_structureTorqueUpper limbmedicine.symptomMuscle contractionEuropean journal of applied physiology and occupational physiology
researchProduct

Effect of electrical stimulation training on the contractile characteristics of the triceps surae muscle.

1993

This study aimed to assess the effects of training using electrical stimulation (ES) on the contractile characteristics of the triceps surae muscle. A selection of 12 subjects was divided into two groups (6 control, 6 experimental). The ES sessions were carried out using a stimulator. Flexible elastomer electrodes were used. The current used discharged pulses lasting 200 microseconds at 70 Hz. Contraction time was 5 s and rest time 15 s. The session lasted 10 min for each muscle. Training sessions were three times a week for 4 weeks. Biomechanical tests were performed using an isokinetic ergometer. Subjects performed plantar flexions of the ankle over a concentric range of movement at diffe…

Adultmedicine.medical_specialtyPhysiologyStimulationIsometric exerciseConcentricPhysical medicine and rehabilitationTriceps surae musclePhysiology (medical)Isometric ContractionMedicineHumansOrthopedics and Sports Medicinebusiness.industryMusclesPublic Health Environmental and Occupational HealthBiomechanicsGeneral MedicineAnatomyElectric StimulationBiomechanical PhenomenaElectrophysiologymedicine.anatomical_structuremedicine.symptomAnklebusinessMuscle contractionMuscle ContractionEuropean journal of applied physiology and occupational physiology
researchProduct

Effects of the type of recovery training on the concentric strength of the knee extensors

1997

The aim of this study was to examine the effects of specific concentric and eccentric training on concentric muscular strength following an initial standardized period of excessive training that combined concentric and eccentric actions. For a period of 12 weeks, 37 young elite female basketball players performed standardized training, which included concentric and eccentric actions at 70% and 110% of one-repetition maximum (1-RM), respectively. They were then divided into three groups that followed 12 week programmes which included concentric (C-E/C, n = 13), eccentric (C-E/E, n = 13) or a combination of both concentric and eccentric (C-E/-E, n = 11) exercises. The standardized and specifi…

medicine.medical_specialtyBasketballAdolescentPhysical Therapy Sports Therapy and RehabilitationBasketballConcentricPhysical strengthReference ValuesIsometric ContractionmedicineHumansEccentricKneeOrthopedics and Sports MedicineExercise physiologyMuscle SkeletalExerciseProbabilityKnee extensorsbusiness.industryReference valuesPhysical EnduranceEccentric trainingPhysical therapyFemalebusinessJournal of Sports Sciences
researchProduct

Co-activation and tension-regulating phenomena during isokinetic knee extension in sedentary and highly skilled humans.

1996

The aim of this study was to examine isokinetic torque produced by highly skilled (HS) and sedentary (S) human subjects, during knee extension, during maximal voluntary and superimposed electrical activation. To verify the level of activation of agonist (vastus lateralis, VL, and vastus medialis, VM) and antagonist muscles (semi-tendineous, ST), during maximal voluntary activation, their myo-electrical activities were detected and quantified as root mean square (rms) amplitude. Ten HS and ten S subjects performed voluntary and superimposed isometric actions and isokinetic knee extensions at 14 angular velocities (from -120 to 300 degrees*s(-1)). The rms amplitude of each muscle was normaliz…

AdultMaleVolitionmedicine.medical_specialtygenetic structuresPhysiologyVastus medialisIsometric exerciseConcentricRoot mean squarePhysiology (medical)Internal medicinemedicineTorqueEccentricHumansOrthopedics and Sports MedicineKneeMuscle SkeletalPhysicsPhysical Education and TrainingPublic Health Environmental and Occupational HealthGeneral MedicineAnatomyElectric StimulationElectrophysiologyAmplitudeTorqueCardiologymedicine.symptomMuscle contractionMuscle ContractionEuropean journal of applied physiology and occupational physiology
researchProduct

Concentric and/or Eccentric Training-Induced Alterations in Shoulder Flexor and Extensor Strength

1997

To examine the effect of specific concentric and eccentric training on muscular strength following an initial standardized period of excessive training, shoulder extensors and flexors were tested. The shoulder is a joint particularly susceptible to injury and requires a specific strength training program. For a period of 12 weeks, subjects performed training, including concentric and eccentric actions. Thereafter, they were divided into three groups that performed specific 12-week programs, including either concentric (C-E/C), eccentric (C-E/E), or a combination of both concentric and eccentric exercises (C-E/C-E). Following the initial period of training, significant increases (p0.05) in p…

medicine.medical_specialtyAdolescentShoulder Jointbusiness.industryPhysical Therapy Sports Therapy and RehabilitationGeneral MedicineAnatomyConcentricPhysical strengthSensitivity and SpecificityKineticsPhysical medicine and rehabilitationIsometric ContractionmedicineEccentric trainingHumansEccentricFemaleRange of Motion ArticularMuscle SkeletalTraining programbusinessExerciseProbabilityJournal of Orthopaedic & Sports Physical Therapy
researchProduct

Theoretical and experimental behaviour of the muscle viscosity coefficient during maximal concentric actions

1994

The aim of this study was to calculate the theoretical variation of the nonlinear damping factor (B) as a function of the muscle shortening velocity, and then to compare the theoretical values with the experimental data obtained on both the elbow flexor and the ankle extensor muscles. The theoretical variation of the B factor was determined from a muscle model consisting of a contractile component in parallel with a viscous damper both in series with an elastic component, and by using, the characteristic equation of the force velocity curve. In this muscle model, the viscous element modelled the inability of the muscle to generate as big a contracting force (while shortening) as possible un…

PhysicsViscosityPhysiologyElbowPublic Health Environmental and Occupational HealthCharacteristic equationGeneral MedicineMechanicsAnatomyIsometric exerciseConcentricCurvatureModels Biologicalmedicine.anatomical_structurePhysiology (medical)medicineDamping factorHumansOrthopedics and Sports Medicinemedicine.symptomAnkleMuscle SkeletalMuscle ContractionMuscle contractionEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

La Relation Couple-Vitesse Angulaire Chez le Sujet Entraine

1995

Physiologybusiness.industryPhysiology (medical)MedicineGeneral MedicinebusinessArchives of Physiology and Biochemistry
researchProduct

Joined effects of pennation angle and tendon compliance on fibre length in isometric contractions: a simulation study.

1998

The main purpose of this study was to investigate the joined behaviours of tendon and pennation angle during maximal isometric contractions. A musculotendon model of the human soleus muscle was simulated as a function of ankle joint position, which determines the soleus length. Analysis of the respective values of tendon length and pennation angle for various musculotendon lengths showed that the primary effects of tendon elasticity and pennation angle variation were to reduce the fibre length variations by absorption of the musculotendon lengthening. The efficiency of this reduction process was the highest at short soleus lengths and principally related to tendon length variations. Finally…

Soleus muscleMaterials sciencePhysiologyMuscle Fibers SkeletalBiomechanicsGeneral MedicineIsometric exerciseAnatomymusculoskeletal systemModels BiologicalTendonBiomechanical PhenomenaTendonsmedicine.anatomical_structurePhysiology (medical)Isometric ContractionmedicineHumansElasticity (economics)AnkleMuscle SkeletalAnkle JointBiomedical engineeringArchives of physiology and biochemistry
researchProduct

Changes induced by eccentric training on force-velocity relationships of the elbow flexor muscles.

1995

The aim of this study was to examine the effects of a short term eccentric training period on force-velocity relationships of the elbow flexor muscles. From a muscle model, the maximal shortening velocity Vo(x) and the af parameter which varies according to the curvature of the force-velocity relationship of the muscle were determined. Sixteen volunteer subjects divided into 2 groups participated in this study (Group Eccentric GE, n = 8; Group Control GC, n = 8). The subjects performed, on an isokinetic ergometer, 2 maximal concentric elbow flexions at different angular velocities (60, 120, 180, 240, 300, 360 degrees s-1) and held maximal and submaximal isometric actions at an elbow flexion…

medicine.medical_specialtyPhysiologyElbowIsometric exerciseElectromyographyConcentricBicepsModels BiologicalPhysical medicine and rehabilitationPhysiology (medical)Isometric ContractionmedicineElbowEccentricHumansOrthopedics and Sports MedicineExercisemedicine.diagnostic_testbusiness.industryElectromyographyMusclesPublic Health Environmental and Occupational HealthGeneral MedicineAnatomymusculoskeletal systemmedicine.anatomical_structureEccentric trainingUpper limbbusinessEuropean journal of applied physiology and occupational physiology
researchProduct

The influence of electrostimulation on mechanical and morphological characteristics of the triceps surae.

1994

The present study assessed the effects of training using electrostimulation of muscle (EMS) on the torque-angular velocity and torque-angle relationships, and the cross-sectional area (CSA) of the triceps surae. Twelve physical education students, divided into two groups (6 controls, 6 experimental), participated in the experiment. The EMS sessions were undertaken using a 'Complex-type' stimulator. Flexible elastomer electrodes were used. The current used discharged pulses lasting for 200 microseconds at a frequency of 70 Hz. The durations of contraction and rest were 5 and 15 s, respectively. The session lasted for 10 min for each muscle. The training regimen was three sessions per week fo…

Adultmedicine.medical_specialtyErgometryRotationbusiness.industryBiomechanicsPhysical Therapy Sports Therapy and RehabilitationIsometric exerciseConcentricLower limbElectric StimulationBiomechanical Phenomenamedicine.anatomical_structureTriceps surae muscleX ray computedIsometric ContractionmedicinePhysical therapyHumansOrthopedics and Sports MedicineAnklebusinessMuscle SkeletalTomography X-Ray ComputedMuscle ContractionJournal of sports sciences
researchProduct