0000000000022700

AUTHOR

Esteban Porcar

showing 14 related works from this author

Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes

2019

Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…

AdultMaleKeratoconusIntraocular pressuremedicine.medical_specialtygenetic structuresContact LensesCorneal StromaKeratoconusEndothelial cell countCorneaProsthesis ImplantationCorneoscleral contact lensCorneal hysteresisTonometry OcularYoung Adult03 medical and health sciences0302 clinical medicineProsthesis FittingCorneaOphthalmologyHumansMedicineProspective StudiesIntracorneal ring segmentIntraocular Pressurebusiness.industryHealthy subjectsProstheses and Implantsmedicine.diseaseElasticityeye diseasesBiomechanical PhenomenaOphthalmologyCross-Sectional Studiesmedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsbusiness030217 neurology & neurosurgeryEye & Contact Lens: Science & Clinical Practice
researchProduct

Fitting Scleral Lenses Less Than 15 mm in Diameter: A Review of the Literature.

2020

OBJECTIVE To perform a comprehensive review of the current and historical scientific literature on fitting small scleral lenses (diameter <15 mm) and clarifying their advantages and disadvantages, in addition to their clinical applications. METHODS The literature search was performed through PubMed from MEDLINE. RESULTS Eleven studies of case series (258 eyes) were found. Indications were similar to those of larger scleral lenses, 74% for corneal irregularities (mainly keratoconus), whereas 26% for ocular surface diseases. In the studies on cases of irregular corneas, visual acuity improved significantly regarding the values before and after fitting the lenses (mean, 0.4-0.03 logMar, respec…

MaleKeratoconusmedicine.medical_specialtyVisual acuitygenetic structuresContact LensesProsthesis Designlaw.inventionCorneal Diseases03 medical and health sciences0302 clinical medicineScleral lenslawOphthalmologyProsthesis FittingmedicineHumansbusiness.industryDaily wearmedicine.diseaseeye diseasesLens (optics)Ophthalmology030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessOcular surface030217 neurology & neurosurgeryScleraEyecontact lens
researchProduct

Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.

2019

Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…

AdultMaleKeratoconusIntraocular pressuremedicine.medical_specialtyVisual acuitygenetic structuresContact LensesVisual rehabilitationKeratoconusRefraction Ocularlaw.inventionCorneal hysteresisCorneal Transplantation03 medical and health sciences0302 clinical medicinelawmedicineHumansAgedRetrospective StudiesAged 80 and overKeratometerIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyGeneral MedicineMiddle Agedmedicine.diseaseeye diseasesSurgeryOphthalmologyEye examination030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryKeratoplasty PenetratingOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management

2019

Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…

MaleCorneal Wavefront AberrationVisual acuitygenetic structuresVisual Acuity0302 clinical medicineIntracorneal ring segmentProsthesis FittingContrast (vision)media_commonmedicine.diagnostic_testQuality assessmentCorneoscleral contact lensProstheses and ImplantsGeneral MedicineMiddle AgedRefractive ErrorsEye examinationFemalemedicine.symptomScleraAdultmedicine.medical_specialtyKeratoconusCorneal ectasiaContact LensesCorneal Stromamedia_common.quotation_subjectKeratoconusContrast SensitivityProsthesis ImplantationYoung Adult03 medical and health sciencesOphthalmologyAberrometrymedicineHumansIntracorneal ring segmentbusiness.industryAberrometryCorneal Topographymedicine.diseaseeye diseasesContact lensOphthalmology030221 ophthalmology & optometrysense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Corneo-scleral contact lens in a piggyback system for keratoconus: A case report.

2017

Purpose: We describe a case of fitting a corneo-scleral contact lens with a multi-aspheric geometry design (MAGD CScL) on top of a daily silicone hydrogel lens (piggyback system) for keratoconus management. Methods: A 48-year-old man using soft toric contact lenses required an improvement in the unsatisfactory quality of his vision. He presented with bilateral asymmetric keratoconus with high myopia in the right eye (RE) and severe myopia in the left eye (LE). In addition, he had low vision in his LE because of a maculopathy. He was fitted with MAGD CScL to correct his irregular astigmatism. A diagnostic trial set was used in the fitting process and the patient was assessed according to a s…

MaleKeratoconusVisual acuityCorneal ectasiagenetic structuresmedia_common.quotation_subjectVisual AcuityKeratoconuslaw.inventionContrast SensitivityCornea03 medical and health sciences0302 clinical medicinelawCorneamedicineContrast (vision)HumansSevere Myopiamedia_commonmedicine.diagnostic_testbusiness.industryGeneral MedicineEquipment DesignMiddle Agedmedicine.diseaseCorneal topographyContact Lenses Hydrophiliceye diseasesCorneo-scleral contact lensContact lensLens (optics)Ophthalmologymedicine.anatomical_structure030221 ophthalmology & optometryOptometrymedicine.symptombusiness030217 neurology & neurosurgeryScleraOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Symptomatic accommodative and binocular dysfunctions from the use of flat-panel displays

2018

AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (ANSBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: One hundred and one VDU users, aged between 20 to 34y, initially participated in the study. This study excluded contact-lens wearers and subjects who had undergone refractive surgery or had any systemic or ocular disease. First, subjects were asked about the type and nature of eye symptoms they experienced during VDU use. Then, a thorough eye examination excluded those subjects with a significant uncorrected refractive error or other problem, such as ocular motility disorders, vertica…

0301 basic medicinenon-strabismic binocular dysfunctionsUlls Acomodació i refraccióRefractive errormedicine.medical_specialtyConvergence insufficiencygenetic structuresAccommodative insufficiencymedicine.medical_treatmentaccommodative dysfunctionsPopulationAudiologyOptometria03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyRefractive surgerygeneral binocular dysfunctionsmedicineeducationInvestigationeye symptomseducation.field_of_studymedicine.diagnostic_testbusiness.industryFusional vergencemedicine.diseaseeye diseasesOphthalmology030104 developmental biologyEye examinationlcsh:RE1-994030220 oncology & carcinogenesis505video display unitbusinessBinocular vision
researchProduct

Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism

2017

Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…

Malemedicine.medical_specialtyKeratoconusCorneal Wavefront AberrationVisual acuityCorneal ectasiagenetic structuresContact LensesVisual AcuityAstigmatismKeratoconusCornea03 medical and health sciences0302 clinical medicineProsthesis FittingOphthalmologyCorneamedicineHumansHigh orderIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyEye Diseases HereditaryCorneoscleral contact lensGeneral MedicineMiddle Agedmedicine.diseaseCorneal topographyeye diseasesOphthalmologyHyperopiamedicine.anatomical_structureEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusinessSclera030217 neurology & neurosurgeryOptometry
researchProduct

Corneal Biomechanical Parameters With Corneoscleral Contact Lenses in Post-Laser In Situ Keratomileusis Eyes

2018

Objective: To evaluate corneal biomechanical parameters wearing corneoscleral contact lenses (CScL) in patients with irregular corneas after laser in situ keratomileusis (LASIK). Methods: Data from patients fitted with CScL because of corneal surface irregularities after complicated LASIK surgery were selected by two eye clinics. Previously and after 1 year of CScL fitting, corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), and central corneal thickness were evaluated. In addition, visual acuity, subjective comfort, and wearing time CScL were reported. Results: The study comprised 27 eyes. Statistically significant differences were fo…

AdultMalemedicine.medical_specialtyIntraocular pressureCorneal Wavefront AberrationVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCorneal resistance factorKeratomileusisLASIKCorneaCorneal hysteresis03 medical and health sciences0302 clinical medicineOphthalmologyMyopiamedicineHumansIn patientCorneal surfaceRefractive surgeryIntraocular PressureRetrospective Studiesbusiness.industryLASIKCorneal hysteresisContact Lenses Hydrophiliceye diseasesBiomechanical PhenomenaScleraOphthalmologymedicine.anatomical_structureCorneoscleral contact lensesPatient Satisfaction030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessSclera030217 neurology & neurosurgery
researchProduct

Visual and ocular effects from the use of flat-panel displays

2016

AIM: To evaluate the prevalence of eye symptoms in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: One hundred and sixteen VDU users with flat-panel display from an urban population participated in the study; their ages ranging from 20 to 34y. There were 60 females and 56 males. An eye examination to rule out the presence of significant uncorrected refractive errors, general binocular dysfunctions and eye conditions was carried out. In order to determine and quantify the type and nature of eye symptoms, participants were asked to answer written questionnaire and the results were grouped by gender, age and number of hours a day spent using a V…

genetic structuresPopulationFlat panelEye symptoms03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyClinical ResearchMedicineComputer visioneducationeye symptomseducation.field_of_studycomputer terminalsbusiness.industryComputer vision syndromeasthenopiaComputer terminalmedicine.diseaseeye diseasesOphthalmologylcsh:RE1-994030221 ophthalmology & optometryOptometrycomputer vision syndromesense organsArtificial intelligencebusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Visual quality with corneo-scleral contact lenses for keratoconus management

2018

Purpose: To assess the visual quality achieved by fitting corneo-scleral contact lenses (CScL) for keratoconus management. Methods: Thirty patients with keratoconus presented to have CScL fitted because of the unsatisfactory visual quality they experienced with their contact lenses or spectacles. The eye examination included visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelialcell count, contrast sensitivity and aberrometry. The fitting process was performed using a diagnostic trial set. Subjective visual quality and comfort, and contact lens wear time were also reported. Patients were monitored for one year. Results: Thr…

Keratoconusmedicine.medical_specialtyVisual acuityCorneal ectasiagenetic structuresmedia_common.quotation_subjectKeratoconus03 medical and health sciences0302 clinical medicineOphthalmologyAberrometrymedicineContrast (vision)In patientmedia_commonmedicine.diagnostic_testbusiness.industryMean ageCorneoscleral contact lensGeneral Medicinemedicine.diseaseeye diseasesContact lensOphthalmologyEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryOptometry
researchProduct

Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

AdultCorneal surgery laserIntraocular pressuremedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPaquimetria corneanagenetic structuresIntraocular pressuremedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityLentes de contatoKeratomileusisCorneal endothelial cell losslaw.invention03 medical and health sciencesCorneal pachymetry0302 clinical medicinePerda de células endoteliais da córneaPressão intraocularlcsh:OphthalmologylawOphthalmologyMyopiaHumansMedicineContact lensesCorneal pachymetryCirurgia da córnea a laserRetrospective Studiesmedicine.diagnostic_testbusiness.industryCorneal TopographyLASIKGeneral MedicineContact Lenses HydrophilicCorneal topographyeye diseasesLens (optics)Contact lensOphthalmologylcsh:RE1-994030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Post-LASIK Visual Quality With a Corneoscleral Contact Lens to Treat Irregular Corneas.

2015

To evaluate the visual quality results of fitting a corneoscleral contact lens with multiaspheric geometry design (MAGD CScL) in subjects with irregular corneas after laser-assisted in situ keratomileusis (LASIK) surgery.From a database of patients evaluated for scleral contact lenses, we identified those with irregular corneas and visual problems after they underwent LASIK surgery for correcting myopia. They manifested unsatisfactory visual quality with their current contact lenses or glasses. Therefore, a MAGD CScL was fitted and monitored according to standardized fitting methodology. A diagnostic trial set was used in the fitting process. Visual acuity (VA), subjective visual quality (S…

AdultMalemedicine.medical_specialtyVisual acuityCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVision DisordersVisual AcuityKeratomileusisProsthesis DesignCorneoscleral contact lens03 medical and health sciences0302 clinical medicineProsthesis fittingPostoperative ComplicationsOphthalmologyProsthesis FittingMyopiaMedicineProsthesis designHumansmedicine.diagnostic_testbusiness.industryAberrometryLASIKCorneal TopographyCorneal topographyContact Lenses Hydrophiliceye diseasesOphthalmology030221 ophthalmology & optometryFemalesense organsCorneal Wavefront Aberrationmedicine.symptombusiness030217 neurology & neurosurgeryEyecontact lens
researchProduct

Prevalence of general binocular dysfunctions in a population of university students.

1997

Although some authors report that the prevalence of general binocular dysfunctions (nonstrabismic) for nonpresbyopes in the clinical population is greater than any condition except refractive error, limited research is available to support this statement. This clinical study determined the presence and clinical implications of these conditions in a population of university students with heavy near visual demands.From a group of second year students who were given a thorough eye examination, 65 students were selected. The criteria for selection were the absence of significant uncorrected refractive error, healthy eyes, and no strabismus or amblyopia.32.3% of the subjects showed general binoc…

Adultmedicine.medical_specialtyRefractive errorConvergence insufficiencyUniversitiesAccommodative insufficiencyPopulationVision DisordersClinical studyEpidemiologymedicinePrevalenceHumanseducationStudentseducation.field_of_studyVision Binocularbusiness.industryAccommodation OcularConvergence Ocularmedicine.diseaseOphthalmologySpainOptometrybusinessPsychologyAccommodationBinocular visionOptometryClinical psychologyOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Corneoscleral contact lenses fitting on irregular corneas after laser-assisted in situ keratomileusis

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

genetic structuressense organseye diseases
researchProduct