0000000000024902

AUTHOR

David P. Piñero

Reliability and Intersession Agreement of Microperimetric and Fixation Measurements Obtained with a New Microperimeter in Normal Eyes.

Purpose: To evaluate the reliability and intersession agreement of measurements of retinal sensitivity as well as of the fixation pattern obtained in healthy eyes with a microperimeter integrating the mechanism of the scanning laser ophthalmoscope (SLO) with the static perimetry. Methods: This study included a sample of 44 healthy eyes of 44 subjects of a mean age of 27.0 ± 8.5 years. In all cases, microperimetric exams with the MAIA system (Centervue, Padova, Italy) were performed in three different sessions to evaluate the intersession repeatability. The consistency of measurements was analyzed by using the Friedman test and by analyzing the correlation between consecutive measurements. A…

research product

Medium-term visual, refractive, and intraocular stability after implantation of a posterior chamber phakic intraocular lens to correct moderate to high myopia.

To evaluate the medium-term refractive and visual outcomes and the complications after implantation of a silicone posterior chamber phakic intraocular lens (PC pIOL) for moderate to high myopia.Oftalmar, Medimar International Hospital, Alicante, Spain.Retrospective case series.Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and intraocular pressure were evaluated during a medium-term follow-up. Postoperative complications were also studied.The study enrolled 35 eyes (mean preoperative spherical equivalent [SE] -10.25 diopters [D] ± 3.19 [SD]) of 20 patients with a mean age of 31.83 ± 8.87 years and a mean follow-up of 57.34 ± 9.24 months. The mean UDVA improved…

research product

Decreased Perifoveal Sensitivity Detected by Microperimetry in Patients Using Hydroxychloroquine and without Visual Field and Fundoscopic Anomalies

Purpose. To evaluate the usefulness of microperimetry in the early detection of the ocular anomalies associated with the use of hydroxychloroquine.Methods. Prospective comparative case series study comprising 14 healthy eyes of 7 patients (group A) and 14 eyes of 7 patients under treatment with hydroxychloroquine for the treatment of rheumatologic diseases and without fundoscopic or perimetric anomalies (group B). A comprehensive ophthalmological examination including microperimetry (MP) and spectral-domain optical coherence tomography was performed in both groups.Results. No significant differences were found in mean MP foveal sensitivity between groupsP=0.18. However, mean MP overall sens…

research product

Current Clinical Application of Microperimetry: A Review.

Microperimetry (MP) is a technology that allows the study of retinal sensitivity at different foveal and parafoveal areas as well as eye fixation. It is a technique of functional evaluation, providing a direct correlation between anatomical and functional outcomes. There are a great variety of studies which evaluate the repeatability or reliability of measurements obtained with this technology and also describe and explore different clinical applications. MP has been shown to be useful in the characterization of sensory and motor conditions, such as amblyopia or nystagmus. Concerning ocular pathology, several studies have confirmed the usefulness of MP for evaluating and analyzing different…

research product

Evaluation of a new nomogram for Ferrara ring segment implantation in keratoconus

AIM: To evaluate the short-term clinical outcomes of Ferrara rings in keratoconus using an optimized nomogram developed after several years of research and retrospective analysis of clinical data. METHODS: This prospective longitudinal non-comparative clinical trial evaluated 88 eyes of 88 patients (age 18-62y) with keratoconus diagnosis from two Spanish centers. Ferrara ring segment (AJL Ophthalmic) implantation was performed in all cases, using the mechanical procedure in 25 eyes (28.4%) and a femtosecond laser-assisted procedure in 63 eyes (71.6%). The ring segments implanted in each case were selected using a new optimized nomogram that considered variables such as anterior corneal asph…

research product

Prevalence of visual impairment and refractive errors in an urban area of Mexico

AIM: To determine the distribution of refractive errors in a school-age population in Quintana Roo (Mexico) in the framework of an international cooperation campaign for the prevention of blindness. METHODS: A sample of 2647 school-age children (ranging from 5 to 14 years old) with a mean age of 9.1±1.9 years old were tested by trained volunteers for distance visual acuity (VA) and refractive errors. The first screening examination included uncorrected distance visual acuity (UDVA) and VA with a +2.00 D lens. Inclusion criteria for a second complete cycloplegic eye examination performed by an optometrist were UDVA <20/25 (0.10 logMAR or 0.8 decimal) and/or VA with +2.00 D ≥20/25. RESULTS: A…

research product

New iPAD-based test for the detection of color vision deficiencies.

Purpose: To develop and validate a new iPad-based color vision test (Optopad). Methods: A total of 341 student eyes were enrolled in a first comparative study between Optopad and the Isihara tests. In a second comparative study, Optopad vs. the Farnworth-Munsell test (FM 100H), a total of 66 adult eyes were included. Besides the agreement between tests, the correlation between FM 100H and Optopad outcomes were investigated. Multiple regression analysis was used to predict the total error score (TES) from contrast thresholds measured with the Optopad test. Results: The Ishihara and Optopad tests detected the same anomalous patients. Concerning FM 100H vs. Optopad, 10 subjects were diagnosed …

research product

Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clinical outcomes

Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…

research product

Prevalence of visual problems in a rural population of Kenya

research product

Are near visual signs and symptoms in multiple sclerosis compatible with convergence insufficiency?

Clinical relevance: Optometric management of neurodegenerative diseases is essential since visual signs, such as double vision, visual acuity reduction, or oculomotricity dysfunctions, are usually present in these subjects over the course of the disease. The present paper can guide clinicians in better managing their patients with multiple sclerosis. Background: Patients with multiple sclerosis present near vision symptoms that may be related to binocular anomalies, but these symptoms have not been investigated and related to specific signs. The aim of the present study was to evaluate the binocular vision in subjects with multiple sclerosis, and to analyse if the near visual signs and symp…

research product

Normal Values for Microperimetry with the MAIA Microperimeter: Sensitivity and Fixation Analysis in Healthy Adults and Children

Purpose To establish normative values of retinal sensitivity and parameters describing the fixation pattern using macular analyzer integrity assessment (MAIA) microperimetry (Centervue, Padova, Italy) in adults and children. Methods A sample of 237 eyes of 237 healthy subjects aged between 10 and 70 years (mean age 30.63 ± 16.23 years) was evaluated using the MAIA microperimeter. The following parameters provided by the MAIA device were evaluated: average threshold (AT), macular integrity, fixation indexes (P1% and P2%), bivariate contour ellipse area (BCEA) for 95% and 63% of points, and horizontal (H) and vertical (V) axes of the ellipse of fixation. Differences between different age-rela…

research product

Fixation pattern analysis with microperimetry in nystagmus patients

Objective: To assess the usefulness of microperimetry (MP) as an additional objective method for characterizing the fixation pattern in nystagmus. Design: Prospective study. Participants: Fifteen eyes of 8 subjects (age, 12–80 years) with nystagmus from the Lluís Alcanyís Foundation (University of Valencia, Spain) were included. Methods: All patients had a comprehensive ophthalmologic examination including a microperimetric examination (MAIA, CenterVue, Padova, Italy). The following microperimetric parameters were evaluated: average threshold (AT), macular integrity index (MI), fixating points within a circle of 1° (P1) and 2° of radius (P2), bivariate contour ellipse area (BCEA) considerin…

research product

The posterior chamber phakic refractive lens (PRL): a review

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…

research product

Colorimetric Characterization of Mobile Devices for Vision Applications

Purpose: Available applications for vision testing in mobile devices usually do not include detailed setup instructions, sacrificing rigor to obtain portability and ease of use. In particular, colorimetric characterization processes are generally obviated. We show that different mobile devices differ also in colorimetric profile and that those differences limit the range of applications for which they are most adequate. Methods: The color reproduction characteristics of four mobile devices, two smartphones (Samsung Galaxy S4, iPhone 4s) and two tablets (Samsung Galaxy Tab 3, iPad 4), have been evaluated using two procedures: 3D LUT (Look Up Table) and a linear model assuming primary constan…

research product

Binocular, Accommodative and Oculomotor Alterations In Multiple Sclerosis: A Review

Multiple sclerosis (MS) is an acquired demyelinating and inflammatory neurodegenerative disease affecting the central nervous system (CNS). Clinical and subclinical ocular disturbances occur in almost all patients with MS. The objective of this narrative review was to collect and summarize the available scientific information on oculomotor, accommodative and binocular alterations that have been reported in MS. A systematic search strategy with the following descriptors was carried out: multiple sclerosis, ocular motility disorders, internuclear ophthalmoplegia, nystagmus, vergences, fixation, pupil reflex, accommodation and stereopsis. According to the search, some oculomotor alterations w…

research product

Characterization of the effect of intracorneal ring segment in corneal ectasia after laser refractive surgery

Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes …

research product