0000000000054760

AUTHOR

Alvaro Gomez

0000-0001-9618-1755

Per-protocol repeat kidney biopsy portends relapse and long-term outcome in incident cases of proliferative lupus nephritis

Abstract Objectives In patients with LN, clinical and histological responses to treatment have been shown to be discordant. We investigated whether per-protocol repeat kidney biopsies are predictive of LN relapses and long-term renal function impairment. Methods Forty-two patients with incident biopsy-proven active proliferative (class III/IV±V) LN from the database of the UCLouvain were included in this retrospective study. Per-protocol repeat biopsies were performed after a median [interquartile range (IQR)] time of 24.3 (21.3–26.2) months. The National Institutes of Health activity index (AI) and chronicity index (CI) scores were assessed in all biopsies. Results Despite a moderate corre…

research product

O33 Per-protocol repeat kidney biopsy portends relapse and long-term outcome in incident cases of proliferative lupus nephritis

Background In patients with Lupus Nephritis (LN), clinical response to treatment and renal histopathology have been shown to be discordant. We investigated whether per-protocol repeat renal biopsies are predictive of LN relapses and long-term impairment of renal function. Methods Forty-two patients with an incident biopsy-proven active proliferative (class III/IV ± V) LN from the LN database of the Universite catholique de Louvain were included in the present retrospective study. Per-protocol repeat kidney biopsies were performed in all patients after a median time of 24.3 (IQR: 21.3–26.2) months. The NIH activity index (AI) and chronicity index (CI) scores were assessed in both baseline an…

research product

Multipactor Effect in a Parallel-Plate Waveguide Partially Filled With Magnetized Ferrite

The aim of this paper is the analysis of the multipactor effect in a parallel-plate waveguide when a ferrite slab, transversally magnetized by a static magnetic field parallel to the waveguide walls, is present. Employing an in-house developed code, numerical simulations are performed to predict the multipactor radio frequency voltage threshold in such a ferrite-loaded waveguide. Variations of the ferrite magnetization field strength and the ferrite slab height are analyzed. Effective electron trajectories are also shown for a better understanding of the breakdown phenomenon, finding different multipactor regimes.

research product

THU0248 GLOMERULAR AND TUBULOINTERSTITIAL LESIONS IN PER-PROTOCOL REPEAT BUT NOT BASELINE KIDNEY BIOPSY PORTEND RELAPSE AND LONG-TERM RENAL FUNCTION IMPAIRMENT, RESPECTIVELY, IN INCIDENT CASES OF PROLIFERATIVE LUPUS NEPHRITIS

Background:In patients with lupus nephritis (LN), clinical response to treatment and renal histopathology have been shown to be discordant. No clinical or laboratory markers have to date been shown to reliably portend renal prognosis, in particular renal function impairment.Objectives:To investigate whether per-protocol repeat renal biopsies are predictive of LN relapses and long-term impairment of renal function.Methods:Forty-two patients with an incident biopsy-proven active proliferative (class III/IV ± V) LN from the LN database of the Université catholique de Louvain were included in the present retrospective study. Per-protocol repeat kidney biopsies were performed in all patients aft…

research product

Novel multipactor studies in RF satellite payloads: Single-carrier digital modulated signals and ferrite materials

In this work it is reviewed the most novel advances in the multipactor RF breakdown risk assessment devoted to RF satellite microwave passive devices employed in space telecommunication systems. On one side, it is studied the effect of transmitting a single-carrier digital modulated signal in the multipactor RF voltage threshold in a coaxial line. On the other hand, an analysis of the multipactor phenomenon in a parallel-plate waveguide containing a magnetized ferrite slab it is presented.

research product

Analysis of multipactor RF breakdown in a waveguide containing a transversely magnetized ferrite

In this paper, the multipactor RF breakdown in a parallel-plate waveguide partially filled with a ferrite slab magnetized normal to the metallic plates is studied. An external magnetic field is applied along the vertical direction between the plates in order to magnetize the ferrite. Numerical simulations using an in-house 3-D code are carried out to obtain the multipactor RF voltage threshold in this kind of structures. The presented results show that the multipactor RF voltage threshold at certain frequencies becomes considerably lower than for the corresponding classical metallic parallel-plate waveguide with the same vacuum gap

research product

Recent advances of the multipactor RF breakdown in RF satellite microwave passive devices

The main goal of this work is the review of the recent advances in the study of the multipactor RF breakdown phenomenon in RF satellite microwave passive devices for space telecommunication applications developed in the Val Space Consortium. In this work several topics related with the multipactor phenomenon will be discussed.

research product