1-Year Outcomes of Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Stents
Abstract Objectives The purpose of this study was to compare the 1-year outcomes of the ABSORB everolimus-eluting bioresorbable scaffold (BRS) (Abbott Vascular, Santa Clara, California) and the XIENCE everolimus-eluting stent (EES) (Abbott Vascular) in patients undergoing percutaneous coronary intervention. Background Randomized studies of the ABSORB BRS have been performed in selected patient and lesion scenarios. The available registries of the ABSORB BRS reflect real-world practice more closely compared with randomized studies, but most of them are limited by the small sample size and the lack of comparative outcomes versus second-generation drug-eluting stents. Methods A total of 1,189 …
Bioresorbable vascular scaffold use for coronary bifurcation lesions: A substudy from GHOST EU registry
Objectives The aim of this study was to evaluate midterm outcomes of bioresorbable vascular scaffolds (BVS) implanted in bifurcation lesions. Background BVS have emerged as an alternative to conventional metallic drug-eluting stents for the treatment of coronary complex lesions. Methods Between November 2011 and January 2014, 1189 patients underwent percutaneous coronary intervention with BVS at 10 European centers (GHOST EU registry). Of these, 289 consecutive patients (302 bifurcation lesions) treated with either single-stenting (n = 260) or double-stenting (n = 42) were evaluated. Results True bifurcations were treated in 44.7%. Intravascular ultrasound and optical coherence tomography w…
Predilation, sizing and post-dilation scoring in patients undergoing everolimus-eluting bioresorbable scaffold implantation for prediction of cardiac adverse events: Development and internal validation of the PSP score
Aims: The aim of the study was to develop a scoring model to evaluate the quality of bioresorbable vascular scaffold (BVS) implantation and determine the model's usefulness in predicting adverse cardiac events. Methods and results: The implantation technique and clinical outcomes of 1,736 lesions treated with BVS were analysed using the GHOST-EU registry. Predilation, scaffold sizing, and post-dilation (PSP) were scored according to the hazard model derived from the weight of these variables. The primary end-point was a one-year device-oriented composite endpoint (DoCE) composed of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation. Def…
TCT-419 Usefulness of a scoring system for predicting adverse cardiovascular events in patients undergoing everolimus-eluting bioresorbable scaffolds implantation: the PSP score
Impact of overlapping on 1-year clinical outcomes in patients undergoing everolimus-eluting bioresorbable scaffolds implantation in routine clinical practice: Insights from the European multicenter GHOST-EU registry
Background Overlapping implantation of bioresorbable scaffolds (BRSs) are frequent in long coronary lesions. Its impact on clinical outcomes is unknown. Objective: To compare the clinical outcomes of patients treated with overlapping BRS with those patients treated with no-overlap BRS. Methods: We analyzed the 1-year clinical outcomes of 1,477 patients treated with BRS in the GHOST-EU registry, according to the implantation of overlapping BRS. Primary endpoint was patient oriented composite endpoint (PoCE) of: all-cause death, any myocardial infarction (MI) and any repeated revascularization. Scaffold thrombosis, according to Academic Research Consortium definition, was also analyzed. Resul…
Bioresorbable Everolimus-Eluting Vascular Scaffold for Long Coronary Lesions
Abstract Objectives The authors sought to investigate 1-year outcomes in patients treated with bioresorbable everolimus-eluting vascular scaffolds (BVS) for “long coronary lesions.” Background The present substudy derived from the GHOST-EU registry included 1,722 lesions in 1,468 consecutive patients, enrolled between November 2011 and September 2014 at 11 European centers. Methods The lesions were divided into 3 groups according to continuous BVS length: 1) shorter than 30 mm; 2) between 30 and 60 mm; and 3) longer than 60 mm. Primary device-oriented endpoint (target lesion failure [TLF]) was defined as a combination of cardiovascular death, target vessel myocardial infarction, or clinical…
Contemporary practice and technical aspects in coronary intervention with bioresorbable scaffolds : a European perspective
Aims Next to patient characteristics, the lack of a standardised approach for bioresorbable vascular scaffold (BVS) implantation is perceived as a potential explanation for the heterogeneous results reported so far. To provide some guidance, we sought to find a consensus on the best practices for BVS implantation and management across a broad array of patient and lesion scenarios. Methods and results Fourteen European centres with a high volume of BVS procedures combined their efforts in an informal collaboration. To get the most objective snapshot of different practices among the participating centres, a survey with 45 multiple choice questions was prepared and conducted. The results of th…
Early and midterm outcomes of bioresorbable vascular scaffolds for ostial coronary lesions: insights from the GHOST-EU registry.
Aims: We aimed to investigate the outcomes of bioresorbable vascular scaffolds (BVS) in coronary ostial lesions. Ostial lesions represent a challenging angiographic subset, with higher event rates compared with non-ostial lesions. BVS might be associated with advantages over the long term, but their safety in this setting remains to be explored. Methods and results: Procedural and 12-month follow-up data from consecutive patients treated with BVS for lesions located at the ostium of the right (RCA), left anterior (LAD) or circumflex (LCX) coronary in 11 European centres were collected. The primary device-oriented endpoint was defined as a combination of cardiovascular death, target vessel m…
Percutaneous coronary intervention with everolimus-eluting bioresorbable vascular scaffolds in routine clinical practice: early and midterm outcomes from the European multicentre GHOST-EU registry
Clinical data on the early and midterm outcomes of bioresorbable vascular scaffolds (BVS) in routine clinical practice are limited. To fill this gap, we report on the early and midterm clinical outcomes of PCI with everolimus-eluting BVS from the large multicentre GHOST-EU registry.Between November 2011 and January 2014, 1,189 patients underwent percutaneous coronary intervention with one or more BVS (Absorb BVS; Abbott Vascular, Santa Clara, CA, USA) at 10 European centres. The primary outcome of interest was target lesion failure (TLF), defined as the combination of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularisation (TLR). A total of 1…
Clinical outcomes of patients with diabetes mellitus treated with Absorb bioresorbable vascular scaffolds: a subanalysis of the European Multicentre GHOST-EU Registry.
Background Data on the clinical performance of bioresorbable scaffolds in patients with diabetes mellitus (DM) are still limited. The present study reported 1-year clinical outcomes associated with the use of everolimus-eluting bioresorbable vascular scaffolds (Absorb BVS; Abbott Vascular, Santa Clara, CA) in DM patients. Methods and Results This was a subanalysis from the GHOST-EU (Gauging coronary Healing with biOresorbable Scaffolding plaTforms in Europe) multicenter retrospective registry including patients treated with Absorb BVS between November 2011 and September 2014. In this study, a comparative analysis stratified according to DM was performed. The primary endpoint was target lesi…