0000000000076851

AUTHOR

María Ramos-alzamora

showing 2 related works from this author

Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT

2021

Purpose To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). Methods We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. Results Mean LV wa…

Adultmedicine.medical_specialtyBiometryAnterior ChamberSignificant negative correlationPositive correlationSwept-source Fourier domainCorrelationLens thicknessOphthalmologyLens CrystallineHumansMedicineOptical coherence tomographybusiness.industrySpur-to-spurReproducibility of ResultsMean ageAxial lengthWhite-to-whiteMiddle AgedClinical routineCrystalline lens riseAxial Length Eyemedicine.anatomical_structureLens (anatomy)Original ArticlebusinessTomography Optical CoherenceOptometryJournal of Optometry
researchProduct

Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism.

2020

Aim To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with low degrees of corneal astigmatism. Methods Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL (FineVision PODFT, PhysIOL s.a., Liege, Belgium) were enrolled. Phacoemulsification with femtosecond laser, capsular tension ring insertion and intraoperative aberrometry were performed in all cases. All IOLs used showed a cylinder power of 1.00 D. Main outcome measures were refractive error and corrected-distance visual acuity (CDVA) and uncorrected-distance visual acuity (UDVA) values. Eyes were evaluated at 4mo post-su…

Refractive errormedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentintraocular lensIntraocular lensAstigmatismtoriclcsh:OphthalmologyClinical ResearchOphthalmologyAberrometrymedicinetrifocalbusiness.industryPhacoemulsificationCataract surgerymedicine.diseaseeye diseasesOphthalmologyastigmatismcataractlcsh:RE1-994phacoemulsificationsense organsmedicine.symptombusinessCorneal astigmatismInternational journal of ophthalmology
researchProduct