0000000000088237

AUTHOR

Amir Ahmad Ajami

showing 4 related works from this author

Effect of pre-heating on the mechanical properties of silorane-based and methacrylate-based composites

2016

Background The use of composites in dental restoration has been commonly criticized, due to their underwhelming mechanical properties. This problem may be solved partially by preheating. The present research aims to determine the effect of preheating on the mechanical properties of two different classes of composites. Material and methods A Silorane-based (Silorane) and a Methacrylate-based (Z250) composite were preheated to different temperatures (25, 37, and 68 °C) and afterwards were tested with the appropriate devices for each testing protocol. The material's flexural strength, elastic modulus, and Vickers microhardness were evaluated. Two-way ANOVA, and Tukey's post hoc were used to an…

Materials sciencePost hocmedicine.medical_treatmentResearchComposite numberOdontología030206 dentistry02 engineering and technologyEsthetic Dentistry021001 nanoscience & nanotechnologyMethacrylateIndentation hardnessCiencias de la salud03 medical and health sciences0302 clinical medicineFlexural strengthmedicineUNESCO::CIENCIAS MÃ DICAS:CIENCIAS MÃ DICAS [UNESCO]Composite material0210 nano-technologyGeneral DentistryElastic modulusDental restoration
researchProduct

Effect of three prophylaxis methods on surface roughness of giomer

2010

Objectives: Plaque and stains are removed by prophylaxis methods from tooth surfaces. Since prophylaxis methods can have a detrimental effect on the surface finish of restorations, the aim of this in vitro study was to investigate the effect of three prophylaxis methods, including pumice with rubber cup, pumice with brush, and air-powder polishing device (APD) on the surface roughness of giomer. Study design: Sixty four cylindrical giomer (Beautifil II, Shofu) samples with a diameter of 6 mm and a height of 2 mm were used. Subsequent to a 3-month period of storage in distilled water at 37ºC, the samples were randomly divided into four groups of 16. In group 1 (control), no prophylaxis proce…

Rubber CupMaterials scienceAtomic force microscopybusiness.industrySurface PropertiesAcrylic ResinsBrushDentistryDental ProphylaxisSurface finishSilicon Dioxide:CIENCIAS MÉDICAS [UNESCO]law.inventionOtorhinolaryngologylawPumiceUNESCO::CIENCIAS MÉDICASSurface roughnessIn vitro studySurgeryProfilometerbusinessGeneral Dentistry
researchProduct

Shear bond strengths of composite resin and giomer to mineral trioxide aggregate at different time intervals

2017

Background The efficacy of the bond between the restorative materials and the pulp capping materials has an important role in the success of vital pulp therapy. Therefore, the aim of this study was to evaluate the shear bond strength of composite resin and giomer to MTA at different time intervals after mixing of MTA. Material and methods Ninety cylindrical MTA samples were prepared and assigned to two groups (n=45) based on the restorative materials used (composite resin or giomer). Each group was subdivided into 3 subgroups (n=15) based on the evaluation intervals (immediately, 2.45 hours and 3 days after mixing MTA). After the bonding procedures, the shear bond strengths of the samples w…

Mineral trioxide aggregateMaterials scienceBond strengthResearch0206 medical engineeringComposite number030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringShear bondPulp cappingOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicinePulp therapyUNESCO::CIENCIAS MÉDICASComposite materialGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

The effect of pre-heating on monomer elution from bulk-fill resin composites

2020

Background The present study was aimed to evaluate the effect of pre-heating of bulk -fill resin composites on monomer elution from them. Material and Methods Three different types of resin composites were used including Tetric N-Ceram Bulk Fill, X-tra Fill and X-tra Base. 10 cylindrical samples were prepared from each resin composites. Before light curing, 5 samples were pre-heated until reaching 68˚C, then 5 other samples were polymerized at room temperature. After 24 hours, release of UDMA, TEGDMA and BIS-GMA monomers were measured by High-Performance Liquid Chromatography analysis. Data analysis was performed by two-way ANOVA test, Games-Howell and Sidak post hoc tests. Results Pre-heat…

chemistry.chemical_classificationMaterials scienceBase (chemistry)ElutionResearchComposite numberBulk fill030206 dentistry:CIENCIAS MÉDICAS [UNESCO]UDMAHigh-performance liquid chromatographyOperative Dentistry and Endodontics03 medical and health scienceschemistry.chemical_compound0302 clinical medicineMonomerchemistryPolymerization030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASComposite materialGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct