0000000000091116

AUTHOR

Belgrano M

Valutazione quantitativa tridimensionale del parenchima polmonare affetto da fibrosi cistica : risultati preliminari

Purpose. The aim of this study was to assess the feasibility of three-dimensional (3D) reconstructions and quantitative analysis of the volume of each component of the lung with cystic fibrosis (CF). Materials and methods. Twenty-two patients with CF (mean age 17±8 yeas) were included in the study. The patients underwent an unenhanced single-slice spiral computed tomography (CT) chest scan with the following parameters: collimation 3 mm, table feed 6 mm×rot-1, reconstruction interval 1 mm, soft tissue reconstruction kernel. Four image data sets were obtained: native axial slices, cine-mode display, virtual bronchographic volumerendered images with algorithm for tissue transition display and…

research product

Introduction to coronary imaging with 64-slice computed tomography

The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities.

research product

Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates

research product

Influenza dei filtri di convoluzione sulla misurazione dei valori di attenuazione della placca durante angiografia coronarica mediante TC multistrato

research product

DETECTION OF LIVER METASTASIS WITH CONTRAST ENHANCED ULTRASONOGRAPHY

research product

Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of coronary angiography

PURPOSE: To assess the variability in attenuation of coronary plaques with multislice CT-angiography (MSCT-CA) in an ex-vivo model with varying convolution kernels. MATERIALS AND METHODS: MSCT-CA (Sensation 16, Siemens) was performed in three ex-vivo left coronary arteries after instillation of contrast material solution (Iomeprol 400 mgI/ml, dilution: 1/80). The specimens were placed in oil to simulate epicardial fat. Scan parameters: slices 16/0.75 mm, rotation time 375 ms, feed/rotation 3.0 mm, mAs 500, slice thickness 1 mm, and FOV 50 mm. Datasets were reconstructed using 4 different kernels (B30f-smooth, B36f-medium smooth, B46f-medium, and B60f-sharp). Each scan was scored for the pre…

research product

Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice computed tomography coronary angiography.

PURPOSE: To assess the effect of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). MATERIALS AND METHODS: One hundred patients (88 males; 59+/-11 years) with suspected coronary artery disease who had undergone conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA, with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 2.8 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol 320 mgI/ml at 4 ml/s and …

research product