0000000000105311

AUTHOR

Christoph Mokry

Chemical studies of Fl (element 114): Heaviest chemically studied element

research product

Actinide and lanthanide thin-layer developments using a drop-on-demand printing system

Actinide and lanthanide thin layers with specific requirements regarding thickness, homogeneity, chemical purity, mechanical stability, and backing properties are applied in a multitude of physics and chemistry experiments. A novel target preparation method, the so-called “Drop-on-Demand” (DoD) technique, based on a commercial nanoliter (nL) dispenser is applied since a few years in the Nuclear Chemistry unit at Johannes Gutenberg University Mainz. The wetting behaviour of the nL droplets on the substrate’s surface is a key parameter determining the spatial distribution of the deposited material after evaporation. By switching from aqueous to organic solvents as well as by substrate surface…

research product

Measurement of the $^{229}$Th isomer energy with a magnetic micro-calorimeter

We present a measurement of the low-energy (0--60$\,$keV) $\gamma$ ray spectrum produced in the $\alpha$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme determines the $^{229}$Th isomer energy to be $8.10(17)\,$eV, corresponding to 153.1(37)$\,$nm, superseding in precision previous values based on $\gamma$ spectroscopy, and agreeing with a recent measurement based on internal conversion electrons. We also measure branching ratios of the r…

research product

TASCAを用いたCn, Nh, Fl化学実験のためのHg, Tl, PbのSiO2及びAu表面に対するオンライン化学吸着研究

Online gas-solid adsorption studies with single atom quantities of Hg, Tl, and Pb on SiO$_{2}$ and Au surfaces were carried out using short-lived radioisotopes with half-lives in the range of 4-49 s. This is a model study to measure adsorption enthalpies of superheavy elements Cn, Nh, and Fl. The short-lived isotopes were produced and separated by the gas-filled recoil separator TASCA at GSI. The products were stopped in He gas, and flushed into gas chromatography columns made of Si detectors whose surfaces were covered by SiO$_{2}$ or Au. The short-lived Tl and Pb were successfully measured by the Si detectors with the SiO$_{2}$ surface at room temperature. On the other hand, the Hg did no…

research product