A Demonstrator for a new Axial PET Concept

2008

In PET imaging, improving sensitivity while maintaining very good spatial resolution is crucial. To achieve this goal, we propose a novel concept of PET scanner, with axially arranged crystals, providing a high sensitivity and a 3D reconstruction of the gamma interaction point. The trans-axial coordinate is given by the crystal hit, while the z coordinate is reconstructed by the weighted distribution of light escaping the crystal and entering into an array of Wave Length Shifting (WLS) strips interleaving the crystal layers. This novel configuration allows full identification of Compton interactions in the crystals that can be included in image reconstruction thus enhancing the sensitivity.…

PhysicsInterleavingInteraction pointPhysics::Instrumentation and Detectorsbusiness.industry3D reconstructionIterative reconstructionSTRIPSlaw.inventionCrystalOpticslawSensitivity (control systems)businessImage resolution2008 IEEE Nuclear Science Symposium Conference Record
researchProduct

Performance of a sustainable asphalt mix incorporating high RAP content and novel bio-derived binder

2019

The recent drive to find ways to increase sustainability and decrease costs in asphalt paving has led researchers to find innovative ways to incorporate more recycled materials and bio-derived binders into mixes with varying success. A new novel bio-derived binder made from refined pine chemistry stabilised with a polymer can increase the sustainability of asphalt mixes while maintaining pavement performance. Laboratory performance testing was conducted on asphalt mixes containing 50% Reclaimed Asphalt Pavement (RAP) by mix weight and the novel bio-derived binder. Results show that the bio-derived binder outperforms the conventional 50/70 pen grade binder mixes with respect to resistance to…

050210 logistics & transportationWaste managementAsphalt021105 building & construction0502 economics and business05 social sciencesSustainability0211 other engineering and technologiesEnvironmental scienceSettore ICAR/04 - Strade Ferrovie Ed Aeroporti02 engineering and technologybio-binder RAP rejuvenator sustainable pavementsCivil and Structural Engineering
researchProduct

Silicon as an Unconventional Detector in Positron Emission Tomography.

2012

Positron emission tomography (PET) is a widely used technique in medical imaging and in studying small animal models of human disease. In the conventional approach, the 511 keV annihilation photons emitted from a patient or small animal are detected by a ring of scintillators such as LYSO read out by arrays of photodetectors. Although this has been a successful in achieving ~5mm FWHM spatial resolution in human studies and ~1mm resolution in dedicated small animal instruments, there is interest in significantly improving these figures. Silicon, although its stopping power is modest for 511 keV photons, offers a number of potential advantages over more conventional approaches. Foremost is it…

PhysicsNuclear and High Energy Physics010308 nuclear & particles physicsbusiness.industryPhysics::Instrumentation and DetectorsDetectorPhysics::Medical PhysicsPhotodetectorScintillator01 natural sciencesParticle detectorLyso-Article030218 nuclear medicine & medical imagingSemiconductor detector03 medical and health sciences0302 clinical medicineOptics0103 physical sciencesMedical imagingbusinessInstrumentationImage resolutionNuclear instrumentsmethods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
researchProduct

A device to measure the effects of strong magnetic fields on the image resolution of PET scanners

2009

Abstract Very high resolution images can be achieved in small animal PET systems utilizing solid state silicon pad detectors. As these systems approach sub-millimeter resolutions, the range of the positron is becoming the dominant contribution to image blur. The size of the positron range effect depends on the initial positron energy and hence the radioactive tracer used. For higher energy positron emitters, such as Ga 68 and Tc 94 m , which are gaining importance in small animal studies, the width of the annihilation point distribution dominates the spatial resolution. This positron range effect can be reduced by embedding the field of view of the PET scanner in a strong magnetic field. In…

PhysicsNuclear and High Energy PhysicsRadioactive tracerAnnihilationPhysics::Instrumentation and Detectorsbusiness.industryResolution (electron density)DetectorField of viewlaw.inventionMagnetic fieldOpticsNuclear magnetic resonancePositronlawPhysics::Accelerator PhysicsbusinessInstrumentationImage resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Development of a High Precision Axial 3-D PET for Brain Imaging

2009

We describe a PET device based on a novel method to extract the coordinates of the interaction point of the 511keV γ rays from 100 mm long and thin LYSO (Lutetium Yttrium OxyorthoSilicate) scintillator bars, positioned axially in the tomograph. The coordinate along the hit crystal is measured by using a hodoscope of Wave Length Shifting (WLS) plastic strips mounted perpendicularly to each plane of scintillators. As photodetectors, new Geiger mode Avalanche PhotoDetectors (G-APDs) with integrated electronics are being used to detect both the hit crystal in a block (x and y coordinates) and the interaction point in the crystal (z coordinate) through the light escaping from the crystal and tra…

PhysicsSIMULATION TOOLKITCOORDINATENuclear and High Energy PhysicsInteraction pointPhysics::Instrumentation and Detectorsbusiness.industrySIMULATION TOOLKIT; PERFORMANCE; COORDINATE; DETECTOR; SCANNER; LENGTHPhotodetectorSTRIPSPERFORMANCEScintillatorAtomic and Molecular Physics and OpticsLyso-law.inventionCrystalSCANNEROpticsHodoscopelawLENGTHbusinessDETECTORImage resolutionNuclear Physics B - Proceedings Supplements
researchProduct

Timing performance of the silicon PET insert probe

2010

Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 2…

SiliconMaterials scienceSiliconPhysics::Instrumentation and DetectorsTransducerschemistry.chemical_elementIntegrated circuitScintillatorTracking (particle physics)Sensitivity and Specificity01 natural sciencesLyso-030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineOpticslaw0103 physical sciencesRadiology Nuclear Medicine and imagingDiodeRadiationCt Spect/Ct Pet/CtRadiological and Ultrasound Technology010308 nuclear & particles physicsbusiness.industryDetectorPublic Health Environmental and Occupational HealthReproducibility of ResultsEquipment DesignGeneral MedicineImage EnhancementEquipment Failure AnalysisTransducerchemistryPositron-Emission TomographybusinessRadiation Protection Dosimetry
researchProduct

A high-resolution PET demonstrator using a silicon "magnifying glass".

2021

Abstract To assist ongoing investigations of the limits of the tradeoff between spatial resolution and noise in PET imaging, several PET instruments based on silicon-pad detectors have been developed. The latest is a segment of a dual-ring device to demonstrate that excellent reconstructed image resolution can be achieved with a scanner that uses highresolution detectors placed close to the object of interest or surrounding a small field-of-view in combination with detectors having modest resolution at larger radius. The outer ring of our demonstrator comprises conventional BGO block detectors scavenged from a clinical PET scanner and located at a 500 mm radius around a 50 mm diameter field…

ScannerPhotonSiliconchemistry.chemical_elementScintillatorPhysics and Astronomy(all)01 natural sciencesArticle030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticssilicon detectors0103 physical sciencesDetectors and Experimental Techniquesmagnifying PETImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorResolution (electron density)high-resolution imagingRadiusPETchemistrybusinessPhysics procedia
researchProduct

Effect of two novel bio-based rejuvenators on the performance of 50% RAP mixes - a statistical study on the complex modulus of asphalt binders and as…

2019

An experimental study was conducted to evaluate the effectiveness of two bio-additives as rejuvenators on the properties of asphalt mixtures containing 50% RAP and their binder constituents containing 37% RAP binder. Before mixing, the rejuvenators were blended with fresh bitumen and the extracted and recovered RAP bitumen, and changes in the rheological properties of the binders were assessed using performance grading (PG) criteria. The results showed that both rejuvenators could improve the low-temperature performance of the aged RAP binder and restore its low-temperature properties. Master curves for the unaged, RTFO-aged, and PAV aged blends were constructed using both the Christensen-A…

CARACTERISTIQUESMaterials science0211 other engineering and technologiesModulusBio basedMELANGE02 engineering and technologyBITUMEASPHALT MIXTURE CHARACTERISATIONRECLAIMED ASPHALT PAVEMENT[SPI.MAT]Engineering Sciences [physics]/MaterialsRECYCLAGE (MATER)ASPHALTE021105 building & construction0502 economics and businessmedicineSettore ICAR/04 - Strade Ferrovie Ed AeroportiStatistical analysisComposite materialCARACTERISATION PHYSICO CHIMIQUERIGIDITECivil and Structural Engineering050210 logistics & transportation05 social sciencesStiffnessBIO-REJUVENATORSSTIFFNESSasphalt mixture characterisation bio-rejuvenators reclaimed asphalt pavement stiffnessBiological materials[SPI.GCIV]Engineering Sciences [physics]/Civil EngineeringDynamic modelsAsphaltMATERIAU RECYCLECOMPOSITION DU MELANGEmedicine.symptom
researchProduct

AX-PET: A novel PET detector concept with full 3D reconstruction

2009

We describe the concept and first experimental tests of a novel 3D axial Positron Emission Tomography (PET) geometry. It allows for a new way of measuring the interaction point in the detector with very high precision. It is based on a matrix of long Lutetium-Yttrium OxyorthoSilicate (LYSO) crystals oriented in the axial direction, each coupled to one Geiger Mode Avalanche Photodiode (G-APD) array. To derive the axial coordinate, Wave Length Shifter (WLS) strips are mounted orthogonally and interleaved between the crystals. The light from the WLS strips is read by custom-made G-APDs. The weighted mean of the signals in the WLS strips has proven to give very precise axial resolution. The ach…

SIMULATION TOOLKIT; COORDINATE; LENGTHNuclear and High Energy PhysicsSIMULATION TOOLKITCOORDINATEImage qualityPhysics::Instrumentation and DetectorsPhysics::Medical PhysicsLYSOSTRIPSLyso-law.inventionMatrix (mathematics)WLSOpticslawLENGTHInstrumentationPhysicsInteraction pointbusiness.industry3D reconstructionDetectorG-APDPETParallaxbusinessPositron Emission Tomography
researchProduct