0000000000122349

AUTHOR

V. Li Vigni

A two-end traveling wave fault location system for MV cables based on LoRa technology

In this paper a new low cost device is proposed for fault location in power distribution system. The device is part of a system that should include several units installed in couples at the two ends of MV cable lines. Their low cost justifies a widespread installation of these devices, moreover other functionalities could be considered so as to enrich the potential of the system for MV cables monitoring and asset management. The system exploits a two-end traveling wave technique, low complexity and low cost solutions both for the analog front end as well as for the communication infrastructure. A LoRa network is indeed considered as wireless modulation technique perfectly suited when commun…

research product

A new approach to calibrate the thermal conditions in space charge measurements on HVDC mini-cables

The PEA method is currently widespread used for space charge measurements in mini-cables in order to qualify the behavior of semicon-dielectric-semicon compound under electric and thermal stress. The main goal of this research is to quantitatively evaluate the relationship between the thermal boundary conditions applied to cables or mini-cables and the maximum local electric field due to the accumulated space charge. Hitherto, several research groups have obtained thermal gradients over the dielectric's radius heating the conductor by Joule effect due to an induced current. In this paper, a numerical approach is offered to calibrate the heat exchange boundary conditions to apply to a sample…

research product

Polarity reversal in HVDC joints - The effect of the axial thermal conduction

It has been shown that the establishment of a thermal gradient over the radius of HVDC cables involves the accumulation of space charge within the dielectric layer. High thermal gradients over the insulation thickness of loaded cables can lead to the inversion of the radial electric field pattern. In this scenarios, transient overvoltages and polarity reversal can lead to local and transitory peaks of electric field. Since the temperature distribution plays an important role in reaching critical values of the electric field, it has been considered interesting to have a more in-depth view of the thermal behavior of HVDC systems close the discontinuities of the geometry along the cable axis. …

research product

Investigation on partial discharges in HVDC cables after polarity reversal events

Due to the accumulation of space charge inside the insulating layer of HVDC cables, the electric field under load conditions may be altered compared to what is established in HVAC cables. For example, a high thermal gradient leads to the inversion of the electric field pattern until the maximum value is reached in proximity of the dielectric-semicon interfaces. These maximum values can be further increased due to transient overvoltages and polarity reversal events until reaching electric field values higher than the rated ones. The main goal of this research is to investigate the possibility that, during these transient phenomena, conditions are created that favor the occurrence of partial …

research product