0000000000136202

AUTHOR

Joan Roselló-ferrando

showing 2 related works from this author

Decellularized tracheal prelamination implant: A proposed bilateral double organ technique

2021

Introduction In tracheal replacement transplantation, prelamination is a critical stage. Nowadays, the most widely used prelamination technique is the prethoracic fascia flap with lateral thoracic artery. We propose a flap based on the internal thoracic artery, which allows a relatively non-aggressive double organ implant, and we have tested its efficacy in decellularized tracheas. Material and methods Tracheas of albino New Zealand rabbits were decellularized following a protocol that uses detergents and cryogenization, sterilized with 1kGy gamma radiation and tutorized with a stent. Bilateral pedicled flaps made of pectoral fascia and a muscular component were harvested through a longitud…

Malemedicine.medical_specialtyBiomedical EngineeringMedicine (miscellaneous)BioengineeringInternal thoracic arteryBiomaterialsmedicine.arterymedicineAnimalsTransplantation HomologousBioprosthesisDecellularizationCell-Free SystemTissue EngineeringLateral thoracic arterybusiness.industryGeneral MedicineFasciaPedicled FlapSurgeryTracheaTransplantationairway animal immune tolerance models tissue engineering trachea transplantsmedicine.anatomical_structureRabbitsImplantbusinessPectoral fasciaArtificial Organs
researchProduct

PERIPHERAL SURFACE DOSE FROM A LINEAR ACCELERATOR: RADIOCHROMIC FILM EXPERIMENTAL MEASUREMENTS OF FLATTENING FILTER FREE VERSUS FLATTENED BEAMS

2020

Abstract There is a growing interest in the use of flattening filter free (FFF) beams due to the shorter treatment times. The reduction of head scatter suggests a better radiation protection to radiotherapy patients, considering the expected decrease in peripheral surface dose (PSD). In this work, PSD of flattened (FF) and FFF-photon beams was compared. A radiochromic film calibration method to reduce energy dependence was used. PSD was measured at distances from 2 to 50 cm to the field border for different square field sizes, modifying relevant clinical parameters. Also, clinical breast and prostate stereotactic body radiotherapy (SBRT) plans were studied. For square beams, FFF PSD is lowe…

MaleSurface (mathematics)Materials scienceRadiosurgerySquare (algebra)Linear particle accelerator030218 nuclear medicine & medical imaging03 medical and health sciencesRadiation Protection0302 clinical medicineOpticsCalibrationHumansRadiology Nuclear Medicine and imagingRadiochromic filmPhotonsRadiationFlattening filter freeRadiological and Ultrasound Technologybusiness.industryRadiotherapy Planning Computer-AssistedPublic Health Environmental and Occupational HealthRadiotherapy DosageGeneral MedicinePeripheral030220 oncology & carcinogenesisParticle AcceleratorsRadiation protectionbusinessRadiation Protection Dosimetry
researchProduct