Comparison of frictional resistance between passive self-ligating brackets and slide-type low-friction ligature brackets during the alignment and lev…

2019

Background To compare the frictional resistance between passive self-ligating brackets and conventional brackets with low-friction ligature under bracket/archwire and root/bone interface during dental alignment and leveling. Material and methods A tridimensional model of the maxilla and teeth of a patient treated with conventional brackets, and slide ligatures was generated employing the SolidWorks modeling software. SmartClip self-ligating brackets and Logic Line conventional brackets were assembled with slide low-friction ligatures, utilizing archwires with different diameters and alloys used for the alignment and leveling stage. Friction caused during the bracket/archwire interface and s…

musculoskeletal diseasesModeling softwareMaterials sciencemedicine.medical_treatmentPhysics::Medical PhysicsOrthodonticsLow frictionStress (mechanics)03 medical and health sciences0302 clinical medicineMathematics::Quantum Algebramedicine030223 otorhinolaryngologyLigatureGeneral DentistryMathematics::Symplectic GeometryOrthodontic FrictionOrthodonticsOrthodontic wireintegumentary systemResearchBracket030206 dentistry:CIENCIAS MÉDICAS [UNESCO]musculoskeletal systemNonlinear Sciences::Exactly Solvable and Integrable SystemsUNESCO::CIENCIAS MÉDICASFrictional resistancehuman activitiesJournal of Clinical and Experimental Dentistry
researchProduct

Influence of Hyrax screw position on dental movement and cortical bone : a study of finite elements

2019

Background Rapid maxillary expansion (RME) has effects on the dental and periodontal structures of the parts involved, which vary according to the design and position of the expansion screw. The purpose of the study was to determine the optimal three-dimensional position of the Hyrax screw to obtain precise control of the dental movement and effect on the bone cortex using the finite element method (FEM). Material and methods RME was performed from the patient whom two Cone-Beam computerized tomography scans (CBCT) were obtained: T1 before expansion, and T2 three months after stabilization of RME. The FEM model was designed with T1 and of Hyrax photographs. FEM was obtained by comparing the…

MolarHyrax0206 medical engineeringOrthodontics02 engineering and technology03 medical and health sciences0302 clinical medicinestomatognathic systemmedicinePeriodontal fiberDisplacement (orthopedic surgery)General DentistryMathematicsOrthodonticsbiologyResearch030206 dentistrybiology.organism_classification:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringFinite element methodSagittal planemedicine.anatomical_structureCoronal planeUNESCO::CIENCIAS MÉDICASCortical bone
researchProduct