0000000000141314

AUTHOR

A. Knecht

showing 6 related works from this author

Cubic boron nitride: A new prospective material for ultracold neutron application

2009

Abstract At the ultracold neutron (UCN) source of the TRIGA research reactor in Mainz, we have measured for the first time the material optical wall-potential of cubic boron nitride. The measurements were performed with a time-of-flight (TOF) spectrometer. The samples investigated had a wall-potential of ( 305 ± 15 ) neV . This value is in good agreement with the result extracted from neutron reflectometry data and theoretical expectations. Because of its high critical velocity for UCN and its good dielectric characteristics, cubic boron nitride coatings (isotopically enriched) will be useful for a number of applications in UCN experiments.

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and DetectorsFOS: Physical sciencesDielectricCritical ionization velocityTRIGACondensed Matter::Materials Sciencechemistry.chemical_compoundNuclear magnetic resonancechemistryBoron nitrideNeutronResearch reactorNeutron reflectometryNuclear Experiment (nucl-ex)Atomic physicsNuclear ExperimentNuclear ExperimentInstrumentation
researchProduct

Measurement of the permanent electric dipole moment of the neutron

2020

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey’s method of separated oscillating magnetic fields with ultracold neutrons. Our measurement stands in the long history of EDM experiments probing physics violating time-reversal invariance. The salient features of this experiment were the use of a 199Hg comagnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic-field changes. The statistical analysis was performed on blinded datasets by two separate groups, while the estimation of systematic effects profited from an unprecedented knowledge of the magne…

Physics - Instrumentation and DetectorsMagnetometerFOS: Physical sciencesGeneral Physics and Astronomy01 natural sciencesMeasure (mathematics)S017EDMlaw.inventionHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)statistical analysislawcesium0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]time reversal: invarianceStatistical analysisNeutronNuclear Physics - ExperimentPhysics::Atomic Physics[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Nuclear Experiment (nucl-ex)Detectors and Experimental Techniques010306 general physicsNuclear ExperimentNuclear ExperimentPhysicsn: electric momentInstrumentation and Detectors (physics.ins-det)Cesium vaporMagnetic fieldElectric dipole moment* Automatic Keywords *Ultracold neutronsElementary Particles and FieldshistoryAtomic physicstime reversal: violationmagnetic field: oscillationParticle Physics - Experiment
researchProduct

Neutron to mirror-neutron oscillations in the presence of mirror magnetic fields

2009

We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', UCN losses would be maximal for B = B'. We did not observe any indication for nn' oscillations and placed a lower limit on the oscillation time of tau_{nn'} > 12.0 s at 95% C.L. for any B' between 0 and 12.5 uT.

PhysicsNuclear and High Energy PhysicsAntiparticle010308 nuclear & particles physicsOscillationAstrophysics::High Energy Astrophysical PhenomenaFOS: Physical sciencesHardware_PERFORMANCEANDRELIABILITYFermion[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences3. Good healthMagnetic fieldNuclear physicsTheoryofComputation_ANALYSISOFALGORITHMSANDPROBLEMCOMPLEXITYAntimatter0103 physical sciencesUltracold neutronsNeutronNuclear Experiment (nucl-ex)010306 general physicsNucleonNuclear ExperimentNuclear Experiment
researchProduct

Test of Lorentz invariance with spin precession of ultracold neutrons

2009

A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms is reported. %57 No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field $b_{\bot} < 2 \times 10^{-20} {\rm eV}$ (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron $|g_n| < 0.3 $eV/$c^2$ m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit $|g_n| < 3 \times …

Physics010308 nuclear & particles physicsGeneral Physics and AstronomyFOS: Physical sciencesElementary particleLorentz covariance[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyDipoleQuantum mechanics0103 physical sciencesPrecessionUltracold neutronsNeutronAtomic physicsNuclear Experiment (nucl-ex)010306 general physicsNucleonSpin (physics)Nuclear Experiment
researchProduct

The proton radius puzzle

2017

High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.

[PHYS]Physics [physics][ PHYS ] Physics [physics]Atomic Physics (physics.atom-ph)FOS: Physical sciences[PHYS.PHYS.PHYS-GEN-PH]Physics [physics]/Physics [physics]/General Physics [physics.gen-ph]Physics - Atomic Physicslaserelectron p: scatteringhydrogen: muonic atomp: size[ PHYS.PHYS.PHYS-GEN-PH ] Physics [physics]/Physics [physics]/General Physics [physics.gen-ph]Physics::Atomic Physicsspectrometerdeuterium: muonic atomNuclear Experimentactivity report
researchProduct

Technical design of the phase I Mu3e experiment

2021

Nuclear instruments & methods in physics research / A 1014, 165679 (2021). doi:10.1016/j.nima.2021.165679

Nuclear and High Energy PhysicsParticle physicsPhysics - Instrumentation and DetectorsPhysics::Instrumentation and Detectorsflavor: violation [lepton]FOS: Physical sciencesElectron7. Clean energy01 natural sciences530muon: decayTechnical designMuon decaysHigh Energy Physics - Experimentdesign [detector]High Energy Physics - Experiment (hep-ex)decay [muon]Scintillating tilesPositronsemiconductor detector: pixelScintillating fibres0103 physical sciencesscintillation counter: fibreddc:530tracking detector010306 general physicsInstrumentationEngineering & allied operationsactivity reportdetector: designPhysicspixel [semiconductor detector]MuonPixel010308 nuclear & particles physicsDetectorMonolithic pixel detectorlepton: flavor: violationInstrumentation and Detectors (physics.ins-det)fibre [scintillation counter]sensitivityLepton flavour violationBeamlineHigh Energy Physics::Experimentddc:620performanceLepton
researchProduct