0000000000144076

AUTHOR

V Caputo

showing 6 related works from this author

Optimal local control and tolerability of three-dimensional conformal radiation therapy in prostate cancer: A single institutional experience of dose…

2013

Aims To evaluate long-term late side effects, clinical and biochemical relapse in non-metastatic prostate cancer patients treated with dose escalation, from 74 to 78 Gy, by means of three dimensional conformal radiation therapy. Materials and Methods Clinical data of 125 patients with prostate cancer who underwent three-dimensional conformal radiation therapy were retrospectively evaluated. All patients were stratified, according to the NCCN classification, in low, intermediate and high risk, and all of them showed histologically proven adenocarcinoma stage T1–T3 with at least 2 years of follow-up. Late toxicity was analyzed using a modified Radiation Therapy Oncology Group toxicity scale. …

MaleCancer ResearchThree dimensional conformal radiation therapyUrinary BladderUrogenital SystemKaplan-Meier EstimateAdenocarcinomaDisease-Free SurvivalBiomarkers Tumor80 and overHumansLate toxicity; Local control; Prostate cancer; Radiation therapy; Three dimensional conformal radiation therapy; Adenocarcinoma; Aged; Aged 80 and over; Biomarkers Tumor; Disease-Free Survival; Gastrointestinal Tract; Humans; Italy; Kaplan-Meier Estimate; Male; Middle Aged; Neoplasm Staging; Prostate-Specific Antigen; Prostatic Neoplasms; Radiation Injuries; Radiotherapy Dosage; Radiotherapy Conformal; Rectum; Retrospective Studies; Urinary Bladder; Urogenital System; Medicine (all); Oncology; Cancer ResearchRadiation InjuriesAgedNeoplasm StagingRetrospective StudiesAged 80 and overProstate cancerTumorRadiotherapyConformalMedicine (all)RectumProstatic NeoplasmsRadiotherapy DosageGeneral MedicineMiddle AgedProstate-Specific AntigenRadiation therapyGastrointestinal TractItalyOncologyLocal controlRadiotherapy ConformalLate toxicityBiomarkers
researchProduct

ALANINE/EPR DOSIMETRY APPLIED TO THE VALIDATION OF A TOTAL BODY IRRADIATION (TBI) PROTOCOL AND TREATMENT PLANNING DOSE CALCULATION USING A HUMANOID P…

2015

L’irraggiamento a corpo intero (Total Body Irradiation - TBI) è una tecnica di radioterapia oncologica di largo impiego nella clinica ematoncologica nell’ambito del trattamento di pazienti avviati al trapianto di midollo osseo o al trapianto di cellule staminali periferiche. La TBI da una parte permette di sopprimere il sistema immunitario del ricevente per prevenire il rigetto del midollo del donatore ed eliminare le cellule neoplastiche residue dai trattamenti chemioterapici. In genere, la modalità di somministrazione della TBI prevede irraggiamenti in 3 giorni consecutivi con un bi-frazionamento giornaliero (2 Gy, 2 volte al giorno con intervallo minimo di 6 ore tra le sedute, per 3 gior…

TBI Alanine ESR EPR Gamma photonsSettore FIS/01 - Fisica SperimentaleSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Sensibilità e stabilità dei dosimetri gel di tipo Fricke esposti ai fotoni nel range clinico in funzione della concentrazione di ferro e degli additi…

2014

Settore FIS/01 - Fisica Sperimentaledosimetro gel FrickeMRI NMR FerroSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

TL dose reconstruction in watch glasses exposed to photon, electron and proton beams

2010

Thermoluminescence dosimetry watch glasses photons electrons protonsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Dependence of MRI sensitivity of Fricke gel dosimeters exposed to clinical photons beams on ferrous ammonium sulfate content

2014

Settore FIS/01 - Fisica SperimentaleGel DosimetryFricke AgaroseSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)MRI
researchProduct

ASPETTI OPERATIVI NELLA VALUTAZIONE DELLA DOSE AL CRISTALLINO DEI LAVORATORI NELLE PROCEDURE INTERVENTISTICHE DI EMODINAMICA.

2015

Recenti studi epidemiologici hanno evidenziato una incidenza di complicanze oculari (cataratte), per esposizione alle radiazioni ionizzanti del cristallino, superiore a quanto ritenuto in passato. Nella sua pubblicazione del 21 aprile 2011 dal titolo “Statement on Tissue Reactions”, sugli effetti tissutali deterministici non cancerogeni delle radiazioni ionizzanti, l’ICRP indica per il cristallino una dose soglia di 0,5 Gy e raccomanda, per esposizioni lavorative, il limite annuale di 20 mSv di dose equivalente come media su un periodo di 5 anni, senza che sia mai superato il valore di 50 mSv in ogni singolo anno. Questo valore è di gran lunga inferiore all’attuale limite di legge che è par…

Occhiali anti-XDosimetriaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct