0000000000147449

AUTHOR

Am Ciciliani

showing 3 related works from this author

Fingerkraftmessung bei der Bedienung von Inhalatoren

2019

60. Kongress der Deutschen Gesellschaft für Pneumologie und Beatmungsmedizin e. V.
researchProduct

Lung Deposition Using the Respimat® Soft Mist™ Inhaler Mono and Fixed-Dose Combination Therapies: An In Vitro/In Silico Analysis

2020

Tiotropium and olodaterol are mainstay treatments for chronic obstructive pulmonary disease (COPD) and yield important clinical improvements, especially when used in fixed-dose combination. Whilst previous studies have shown consistent delivery of tiotropium to the lungs with the Respimat® inhaler, no such study has been carried out for olodaterol or the components of their fixed-dose combination (TIO/OLO). Combining in vitro and in silico models, we measured the amount of drug retained in the mouth–throat area, entering the trachea and reaching the lung periphery. We applied a hybrid deposition model that considered the experimentally determined output of an Alberta throat model (in vitro …

Pulmonary and Respiratory MedicineCOPDRespimatLungbusiness.industryInhalerFixed-dose combinationOlodaterolrespiratory systemPharmacologymedicine.diseaseIn vitrorespiratory tract diseases03 medical and health scienceschemistry.chemical_compound0302 clinical medicinemedicine.anatomical_structure030228 respiratory systemchemistryDrug deliveryMedicine030212 general & internal medicinebusinessCOPD: Journal of Chronic Obstructive Pulmonary Disease
researchProduct

Handling forces for the use of different inhaler devices.

2019

Abstract Age and comorbidities can impact on the success of handling an inhaler. In this pilot study, we assessed finger strength in 62 participants (aged 5–17 years [n = 20], 18–65 years [n = 22] and > 65 years [n = 20]) by using different types of inhalers with integrated sensors (Respimat®, Breezhaler®, Aerolizer®, Genuair®, Diskus®, Ellipta®, HandiHaler®, Turbohaler® and a pressurized metered-dose inhaler [Atrovent®]). Parameters under investigation included the spontaneous and maximum achievable force and torque required to operate devices. Satisfaction with individual inhalers, and the relationship between satisfaction and strength, were also assessed. There was a marked difference in…

AdultMalemedicine.medical_specialtyAdolescentPharmaceutical SciencePilot Projects02 engineering and technology030226 pharmacology & pharmacyFingers03 medical and health sciencesYoung Adult0302 clinical medicineAge groupsRheumatic DiseasesAdministration InhalationMedicineHumansChildAgedAged 80 and overHand Strengthbusiness.industryInhalerNebulizers and VaporizersHealthy subjectsAge FactorsRheumatic diseaseEquipment DesignMiddle Aged021001 nanoscience & nanotechnologyPatient preferenceDry-powder inhalerPatient SatisfactionCase-Control StudiesChild PreschoolPhysical therapyFemale0210 nano-technologybusinessInternational journal of pharmaceutics
researchProduct