0000000000165364

AUTHOR

C. Castellano

showing 2 related works from this author

Development and analysis of the Soil Water Infiltration Global database

2018

27 Pags.- 11 Tabls.- 8 Figs. © Author(s) 2018. This work is distributed under the Creative Commons Attribution 4.0 License.

Condutividade Hidráulica[SDV]Life Sciences [q-bio]0208 environmental biotechnology02 engineering and technologySilt910computer.software_genreSoilRING INFILTROMETERS900 Geschichte und Geografie::910 Geografie Reisen::910 Geografie ReisenHydraulic conductivityELECTRICAL-CONDUCTIVITYAgricultural landddc:550Meteorology & Atmospheric SciencesSATURATED HYDRAULIC CONDUCTIVITYGeosciences Multidisciplinarydatabaselcsh:Environmental sciences2. Zero hungerlcsh:GE1-350DatabaseIN-SITUlcsh:QE1-996.5Geology04 agricultural and veterinary sciencesPE&RCPedo-transfer functions6. Clean waterInfiltration (hydrology)HYDROPHYSICAL PARAMETERS[SDE]Environmental SciencesPhysical SciencesINFILTRATION GLOBAL DATABASEHidrologiaHydraulic conductivityPHYSICAL-PROPERTIESSANDY SOILTENSION INFILTROMETEREcology and EnvironmentPedotransfer functionPEDOTRANSFER FUNCTIONSLife ScienceSOIL INFILTRATION MEASUREMENTSLand surface modelsInfiltration (hydrology)Soil Water Infiltration Global databaseANALYSIS OF THE SOIL WATERScience & TechnologyLand useInfiltration15. Life on land020801 environmental engineeringInfiltraçãolcsh:GeologySoloInfiltration Land surface models Land use Pedo-transfer functionsSWIGAgriculture and Soil ScienceData qualityITC-ISI-JOURNAL-ARTICLEEarth and Environmental SciencesINFILTROMETER MEASUREMENTSLand useSoil water040103 agronomy & agriculture0401 agriculture forestry and fisheriesGeneral Earth and Planetary SciencesEnvironmental scienceHydrologyITC-GOLDcomputer
researchProduct

Evaluation of esophagogastric junction relaxation by 4-second Integrated Relaxation Pressure in achalasia using High Resolution Manometry with water-…

2014

Background Relaxation of the esophagogastric junction (EGJ) is now evaluated calculating 4-second integrated relaxation pressure (4-s IRP) by high resolution manometry (HREPT). Solid-state catheters have been used to define abnormal values. Our aim was to evaluate 4-s IRP in esophageal achalasia using HREPT with perfused catheters. Methods From June 2009 to June 2013, 936 HREPT studies have been performed in our unit. Of these, 194 patients having treated achalasia were excluded. Control group was constituted by 695 patients without achalasia, and 47 patients with untreated achalasia constituted the study group. HREPT was performed with water-perfused catheters. To establish the cut-off val…

AdultMalemedicine.medical_specialtyCathetersAdolescentManometryPhysiologyMuscle RelaxationAchalasiaGastroenterologyYoung AdultReference ValuesInternal medicinePressuremedicineotorhinolaryngologic diseasesHumanssclerodermaEsophagogastric junctionHigh resolution manometryAgedAged 80 and overReceiver operating characteristicEndocrine and Autonomic Systemsbusiness.industryhigh resolution manometryGastroenterologyArea under the curveWaterMuscle SmoothMiddle Agedlower esophageal sphincter relaxationmedicine.diseaseEsophageal Achalasiaachalasiaesophageal manometryROC CurveArea Under Curveesophagogastric junction relaxationFemaleEsophagogastric JunctionNuclear medicinebusiness
researchProduct