0000000000172553
AUTHOR
J. Thornhill
The SAGE spectrometer: A tool for combined in-beam gamma-ray and conversion electron spectroscopy
International audience; The sage spectrometer allows simultaneous in-beam -ray and internal conversion electron measurements, by combining a germanium detector array with a highly segmented silicon detector and an electron transport system. sage is coupled with the ritu gas- lled recoil separator and the great focal-plane spectrometer for recoil-decay tagging studies. Digital electronics are used both for the ray and the electron parts of the spectrometer. sage was commissioned in the Accelerator Laboratory of the University of Jyvaskyla in the beginning of 2010.
Combined in-beam gamma-ray and conversion electron spectroscopy with radioactive ion beams. Simulations of a silicon detector for the SPEDE spectrometer
In-beam gamma-ray and electron spectroscopy have been widely used as tools to study the broad variety of phenomena in nuclear structure. The SPEDE spectrometer is a new device to be used in conjunction with the MINIBALL germanium detector array to enable the detection of internal conversion electrons in coincidence with gamma rays from de-exciting nuclei in radioactive ion beam experiments at the upcoming HIE-ISOLDE facility at CERN, Switzerland. Geant4 simulations were carried out in order to optimise the design and segmentation of the silicon detector to achieve good energy resolution and performance. ispartof: pages:1-4 ispartof: EPJ Web ofConferences vol:63 pages:1-4 ispartof: Heavy Ion…
In-beam study of 253No using the SAGE spectrometer
The heavy actinide nucleus 253No (Z = 102) was studied using the (S)ilicon (A)nd (Ge)rmanium (SAGE) spectrometer allowing simultaneous in-beam $\gamma$ -ray and conversion electron spectroscopy at the accelerator laboratory of the University of Jyvaskyla. Using the recoil-tagging technique, $\gamma$ -electron coincidences have allowed for the extension of the level scheme in the lower-spin region of the yrast band. In addition, internal conversion coefficient (ICC) measurements to establish the multipolarity of transitions have been performed. Measurement of the interband-intraband branching ratios supports the assignment of the Nilsson band-head configuration $9/2^{-}[734]$ assigned in pre…
The SPEDE spectrometer
8 pags., 10 figs., 2 tabs.
Transmission Efficiency of the SAGE Spectrometer Using GEANT4
The new SAGE spectrometer allows simultaneous electron and γ-ray in-beam studies of heavy nuclei. A comprehensive GEANT4 simulation suite has been created for the SAGE spectrometer. This includes both the silicon detectors for electron detection and the germanium detectors for γ-ray detection. The simulation can be used for a wide variety of tests with the aim of better understanding the behaviour of SAGE. A number of aspects of electron transmission are presented here.
AGATA-Advanced GAmma Tracking Array
WOS: 000300864200005