0000000000174827

AUTHOR

M. Manfredi

showing 5 related works from this author

The magnet of the scattering and neutrino detector for the SHiP experiment at CERN

2019

The Search for Hidden Particles (SHiP) experiment proposal at CERN demands a dedicated dipole magnet for its scattering and neutrino detector. This requires a very large volume to be uniformly magnetized at B > 1.2 T, with constraints regarding the inner instrumented volume as well as the external region, where no massive structures are allowed and only an extremely low stray field is admitted. In this paper we report the main technical challenges and the relevant design options providing a comprehensive design for the magnet of the SHiP Scattering and Neutrino Detector.

TechnologyPhysics - Instrumentation and Detectorswigglers and undulators)magnet: designPermanent magnet devicesPhysics::Instrumentation and Detectorsengineering01 natural sciences7. Clean energy09 Engineering030218 nuclear medicine & medical imagingradiation hardened magnetsSubatomär fysik0302 clinical medicineDipole magnetSubatomic PhysicsNeutrino detectorsDetectors and Experimental TechniquesInstruments & InstrumentationInstrumentationphysics.ins-detAcceleration cavities and magnets superconducting (high-temperature superconductor; radiation hardened magnets; normal-conducting; permanent magnet devices; wigglers and undulators)Mathematical PhysicsPhysics02 Physical SciencesLarge Hadron ColliderInstrumentation and Detectors (physics.ins-det)magnet: technologyNuclear & Particles Physicsbending magnetneutrino: detectorNeutrino detectornormal-conductingAcceleration cavities and magnets superconducting (high-temperature superconductorproposed experimentCERN LabRadiation hardened magnetsFOS: Physical sciencesNormal-conductingAccelerator Physics and InstrumentationNuclear physics03 medical and health sciences0103 physical sciencespermanent magnet devices[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Wigglers and undulators)normal-conducting magnetsScience & Technology010308 nuclear & particles physicsScatteringLarge detector systems for particle and astroparticle physicsAcceleratorfysik och instrumenteringLarge detector systems for particle physicsHigh temperature superconductors Neutrons Permanent magnets Ships Superconducting magnets Wigglers Astroparticle physics Comprehensive designs Massive structures Neutrino detectors Normal-conducting Radiation-hardened Ship experiments Technical challenges Particle detectorsVolume (thermodynamics)MagnetAcceleration cavities and magnets superconducting (high-temperature superconductor; Large detector systems for particle and astroparticle physics; Neutrino detectors; Normal-conducting; Permanent magnet devices; Radiation hardened magnets; Wigglers and undulators)High Energy Physics::Experimentneutrino detectors
researchProduct

Brainstem reflex circuits revisited

2004

Our current understanding of brainstem reflex physiology comes chiefly from the classic anatomical-functional correlation studies that traced the central circuits underlying brainstem reflexes and establishing reflex abnormalities as markers for specific areas of lesion. These studies nevertheless had the disadvantage of deriving from post-mortem findings in only a few patients. We developed a voxel-based model of the human brainstem designed to import and normalize MRIs, select groups of patients with or without a given dysfunction, compare their MRIs statistically, and construct three-plane maps showing the statistical probability of lesion. Using this method, we studied 180 patients with…

Adult; Aged; 80 and over; Blinking; Brain Stem Infarctions; diagnosis/physiopathology; Brain Stem; physiopathology; Electromyography; Female; Humans; Jaw; Magnetic Resonance Imaging; Male; Masseter Muscle; Middle Aged; Reflex; AbnormalAdultMalemedicine.medical_specialtyBrain Stem InfarctionsClinical neurophysiologyReflex80 and overmedicineHumansCorneal reflexAgedAged 80 and overBlinkingReflex AbnormalElectromyographyMasseter MuscleDental occlusionAnatomyMiddle AgedMagnetic Resonance Imagingdiagnosis/physiopathologyPonsJawCiliospinal reflexAbnormalReflexFemaleNeurology (clinical)BrainstemphysiopathologyPsychologyJaw jerk reflexBrain StemBrain
researchProduct

Time to onset of bisphosphonate-related osteonecrosis of the jaws: a multicentre retrospective cohort study

2017

Objectives: Osteonecrosis of the jaw (ONJ) is a potentially severe adverse effect of bisphosphonates (BP). Although the risk of ONJ increases with increasing duration of BP treatment, there are currently no reliable estimates of the ONJ time to onset (TTO). The objective of this study was to estimate the TTO and associated risk factors in BP-treated patients. Subjects and Methods: Retrospective analysis of data from 22 secondary care centres in seven countries relevant to 349 patients who developed BP-related ONJ between 2004 and 2012. Results: The median (95%CI) TTO was 6.0 years in patients treated with alendronate (n = 88) and 2.2 years in those treated with zoledronate (n = 218). Multiv…

MalebisphosphonateTime Factorsmedicine.medical_treatmentOsteoporosis0302 clinical medicineRisk Factors80 and overosteoporosijaw osteonecrosiAged 80 and overBone Density Conservation AgentsDiphosphonatesjaw osteonecrosisjaw osteonecrosis bisphosphonates breast cancer multiple myeloma prostate cance osteoporosisIncidenceIncidence (epidemiology)Otorhinolaryngology2734 Pathology and Forensic MedicineMiddle Agedprostate cancermultiple myeloma030220 oncology & carcinogenesisBisphosphonate-Associated Osteonecrosis of the JawFemaleAdultmedicine.medical_specialty2734Drug Administration SchedulePathology and Forensic Medicine03 medical and health sciencesbreast cancerbisphosphonates; breast cancer; jaw osteonecrosis; multiple myeloma; osteoporosis; prostate cancer; Adult; Aged; Aged 80 and over; Bisphosphonate-Associated Osteonecrosis of the Jaw; Bone Density Conservation Agents; Cross-Sectional Studies; Diphosphonates; Drug Administration Schedule; Female; Humans; Incidence; Male; Middle Aged; Multivariate Analysis; Proportional Hazards Models; Retrospective Studies; Risk Factors; Time Factors; Otorhinolaryngology; 2734; Pathology and Forensic Medicine; Dentistry (all)Internal medicinemedicineHumansBisphosphonates; Breast cancer; Jaw osteonecrosis; Multiple myeloma; Osteoporosis; Prostate cancer; Otorhinolaryngology2734 Pathology and Forensic Medicine; Dentistry (all)prostate canceAdverse effectGeneral DentistrybisphosphonatesAgedProportional Hazards ModelsRetrospective StudiesBisphosphonate-associated osteonecrosis of the jawbusiness.industryProportional hazards modelRetrospective cohort study030206 dentistryBisphosphonatemedicine.diseaseosteoporosisSurgeryCross-Sectional StudiesOtorhinolaryngologyMultivariate AnalysisDentistry (all)businessOsteonecrosis of the jaw
researchProduct

Fast simulation of muons produced at the SHiP experiment using Generative Adversarial Networks

2019

This paper presents a fast approach to simulating muons produced in interactions of the SPS proton beams with the target of the SHiP experiment. The SHiP experiment will be able to search for new long-lived particles produced in a 400~GeV$/c$ SPS proton beam dump and which travel distances between fifty metres and tens of kilometers. The SHiP detector needs to operate under ultra-low background conditions and requires large simulated samples of muon induced background processes. Through the use of Generative Adversarial Networks it is possible to emulate the simulation of the interaction of 400~GeV$/c$ proton beams with the SHiP target, an otherwise computationally intensive process. For th…

TechnologyPhysics - Instrumentation and DetectorsProtonPhysics::Instrumentation and DetectorsComputer sciencebackground: inducedNuclear TheoryDetector modelling and simulations I (interaction of radiation with matter interaction of photons with matter interaction of hadrons with matter etc); Simulation methods and programs01 natural sciences09 EngineeringHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]muon: momentumDetectors and Experimental TechniquesNuclear Experimentphysics.ins-detGeneralLiterature_REFERENCE(e.g.dictionariesencyclopediasglossaries)InstrumentationInstruments & InstrumentationMathematical PhysicsDetector modelling and simulations I (interaction of radiation with matter interaction of photons with matter interaction of hadrons with matter etc)02 Physical Sciencesinteraction of photons with matterInstrumentation and Detectors (physics.ins-det)p: beammuon: productionDetector modelling and simulations INuclear & Particles Physicsinteraction of hadrons with matterParticle Physics - Experimentperformancedata analysis methodDetector modelling and simulations I (interaction of radiation with matterFOS: Physical sciencesAccelerator Physics and Instrumentation0103 physical sciencesnumerical methodsddc:610[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Aerospace engineering010306 general physicsnumerical calculationsetc)MuonScience & Technologyhep-ex010308 nuclear & particles physicsbusiness.industryNumerical analysisAcceleratorfysik och instrumenteringCERN SPSPhysics::Accelerator PhysicsHigh Energy Physics::ExperimentSimulation methods and programsbusinessGenerative grammar
researchProduct

The experimental facility for the Search for Hidden Particles at the CERN SPS

2019

The Search for Hidden Particles (SHiP) Collaboration has shown that the CERN SPS accelerator with its 400 $\mathrm{\small GeV/c}$ proton beam offers a unique opportunity to explore the Hidden Sector. The proposed experiment is an intensity frontier experiment which is capable of searching for hidden particles through both visible decays and through scattering signatures from recoil of electrons or nuclei. The high-intensity experimental facility developed by the SHiP collaboration is based on a number of key features and developments which provide the possibility of probing a large part of the parameter space for a wide range of models with light long-lived superweakly interacting particles…

TechnologyPhysics - Instrumentation and Detectorsbackground: inducedlarge detector systems for particle and astroparticle physicsSPSbeam transportElectron7. Clean energy01 natural sciences09 Engineeringdark matter detectors (wimps axions etc.)High Energy Physics - Experiment030218 nuclear medicine & medical imaginglaw.inventionNeutrino detectorHigh Energy Physics - Experiment (hep-ex)0302 clinical medicineRecoillawetc.)[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Neutrino detectorsDetectors and Experimental TechniquesNuclear Experimentphysics.ins-detInstruments & InstrumentationInstrumentationbackground: suppressionMathematical Physicsnucleus: recoilPhysicsRange (particle radiation)tau neutrino02 Physical SciencesLarge Hadron Colliderbeam lossInstrumentation and Detectors (physics.ins-det)p: beamNuclear & Particles Physicsvacuum systemparticle: interactionDark Matter detectors (WIMPbeam opticsNeutrino detectorp: beam dumpPhysics - Instrumentation and Detectorproposed experimentParticle Physics - Experimentzirconium: admixtureFOS: Physical sciencesAccelerator Physics and Instrumentationbeam: ejectionp: targetHidden SectorNuclear physicsKKKK: SHiP03 medical and health sciences0103 physical sciences[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Beam dumpnumerical calculationsmuon: shieldingdetector: designactivity reportDark Matter detectors (WIMPsScience & Technologyhep-ex010308 nuclear & particles physicsLarge detector systems for particle and astroparticle physicsbeam-dump facilityAcceleratorfysik och instrumenteringCERN SPSHidden sectoraxionaxions etc.)Large detector systems for particle and astroparticle physicmolybdenum: alloyPhysics::Accelerator Physicstarget: designtitanium: admixtureBeam (structure)neutrino detectors
researchProduct