0000000000175246

AUTHOR

Ricardo Ortega-aranegui

showing 4 related works from this author

Pre-operative evaluation of the volume of bone graft in sinus lifts by means of CompuDent

2009

Objective: This study aims to evaluate the usefulness of the CompuDent program in determining the pre-operative volume of bone graft in maxillary sinus floor lifts, and to calculate the volume of graft necessary for rehabilitation using varying lengths of implants. Study design: Based on the CompuDent program, we calculated the volume of graft necessary for 47 sinus lifts. This volume was measured in order to raise the floor of each sinus to 13.4 and 15 mm in height. Results: The average volume of graft in order to achieve a lift of 13?4 mm was 2.42 cm³ for the right maxillary sinus, with a range from 1.4 cm³ to 4.1 cm³, and 2.50 cm³ for the left maxillary sinus, with a range from 1.04 cm³ …

AdultMaleMaxillary sinusRight maxillary sinusDentistryX ray computedPreoperative CareHumansMedicineGeneral DentistryAgedOrthodonticsBone Transplantationbusiness.industryMaxillary SinusMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Left maxillary sinusTomography x ray computedmedicine.anatomical_structureOtorhinolaryngologyBone transplantationUNESCO::CIENCIAS MÉDICASFemaleSurgeryTomography X-Ray ComputedbusinessPre-operative evaluationSoftwareMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Effects of localmelatonin application on post-extraction sockets after third molar surgery: a pilot study

2014

Objectives: The purpose of this study was to assess the anti-inflammatory, analgesic and osteogenic early effects of melatonin on post-extraction sockets ofpatients requiring third molars extraction. Study Design: A randomized, triple-blind clinical trial was made using a split-mouth design. Both lower third molars of 10 patients were extracted and 3 mg of local melatonin or placebo were applied. Concentrations of interleukin-6 and nitrotyrosine were determined on samples of the clot from the socket by independent ELISA tests. Radiographic bone density was evaluated by measuring Hounsfield Units in panoramic and cross sections obtained by digital scanner. Statistycal analysis by Kolmogorov-…

MaleMolarBone densityAdministration TopicalRadiographyDentistryPilot ProjectsOdontologíaPlaceboMelatoninYoung Adultchemistry.chemical_compoundDouble-Blind MethodBone DensityHounsfield scalemedicineHumansTooth SocketGeneral DentistryDental alveolusMelatoninInterleukin-6business.industryResearchNitrotyrosine:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludOtorhinolaryngologychemistryTooth ExtractionUNESCO::CIENCIAS MÉDICASFemaleMolar ThirdSurgeryOral Surgerybusinessmedicine.drug
researchProduct

In vitro comparison of primary stability of two implant designs in D3 bone

2016

Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…

02 engineering and technologyIn Vitro Techniques03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral DentistryOrthodonticsDental Implantsbusiness.industryResearchSignificant differenceImplant designDental Implantation Endosseous030206 dentistry021001 nanoscience & nanotechnologyImplant stability quotient:CIENCIAS MÉDICAS [UNESCO]Denture RetentionResonance frequency analysisOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgery0210 nano-technologybusiness
researchProduct

Quantification of growth factors by using a new system for obtaining platelet-rich plasma

2010

Objective: To verify the performance of a new method for obtaining platelet-rich plasma, while avoiding contami- nation of the sample during its processing. Study Design: Twenty healthy patients were selected, from whom 21 ml of blood was etracted. �e then pro- Design: Twenty healthy patients were selected, from whom 21 ml of blood was etracted. �e then pro- esign: Twenty healthy patients were selected, from whom 21 ml of blood was etracted. �e then pro- ceeded to study the platelets and growth factors in basal blood after centrifuging the sample by using a new closed system for obtaining platelet-rich plasma (PRP). Results: After centrifuging the blood sample, double the amount of platelet…

ChemistryPlatelet-Rich PlasmaGrowth factormedicine.medical_treatmentInsulinCentrifugationHematology:CIENCIAS MÉDICAS [UNESCO]AndrologyYoung AdultOtorhinolaryngologyBasal (medicine)Platelet-rich plasmaImmunologyUNESCO::CIENCIAS MÉDICASmedicineHumansIntercellular Signaling Peptides and ProteinsSurgeryPlateletPlatelet concentrateSistema circulatorioGeneral DentistryTransforming growth factor
researchProduct