CFRP STRUCTURAL CAPACITORS: EFFECT OF DAMAGE AND MECHANICAL LOAD ON CAPACITANCE
Aim of this work is to study the effect of mechanical load and damages, on the performance of structural capacitors, made by CFRP composite laminates with a PET dielectric film (treated with sodium hydroxide) inserted at the laminate middle-plane. Such capacitors have been characterized by ILSS and tensile tests and the properties so estimated were compared to those of the simple CFRP. By measuring the capacitance before mechanical loading, under loading and after unloading, it has been observed that, due to the damage of the CFRP layers, proved also by proper fractographic analysis, at high strain level the capacitance decreases although it exhibits a complete recovery after unloading. Suc…