Association between low-frequency ultrasound and hip fractures - comparison with DXA-based BMD

Background New methods for diagnosing osteoporosis and evaluating fracture risk are being developed. We aim to study the association between low-frequency (LF) axial transmission ultrasound and hip fracture risk in a population-based sample of older women. Methods The study population consisted of 490 community-dwelling women (78–82 years). Ultrasound velocity (VLF) at mid-tibia was measured in 2006 using a low-frequency scanning axial transmission device. Bone mineral density (BMD) at proximal femur measured using dual-energy x-ray absorptiometry (DXA) was used as the reference method. The fracture history of the participants was collected from December 1997 until the end of 2010. Lifestyl…

research product

Correlation of Tibial Low-Frequency Ultrasound Velocity with Femoral Radiographic Measurements and BMD in Elderly Women

The ultrasonic axial transmission technique has been proposed as a method for cortical bone characterization. Using a low enough center frequency, Lamb modes can be excited in long bones. Lamb waves propagate throughout the cortical bone layer, which makes them appealing for characterizing bone material and geometrical properties. In the present study, a prototype low-frequency quantitative ultrasonic axial transmission device was used on elderly women (n = 132) to investigate the relationships between upper femur geometry and bone mineral density (BMD) and tibial speed of sound. Ultrasonic velocities (V) were recorded using a two-directional measurement set-up on the midtibia and compared …

research product

Photo-acoustic excitation and detection of guided ultrasonic waves in bone samples covered by a soft coating layer

Photo-acoustic (PA) excitation was combined with skeletal quantitative ultrasound (QUS) for multi-mode ultrasonic assessment of human long bones. This approach permits tailoring of the ultrasonic excitation and detection so as to efficiently detect the fundamental flexural guided wave (FFGW) through a coating of soft tissue. FFGW is a clinically relevant indicator of cortical thickness. An OPO laser with tunable optical wavelength, was used to excite a photo-acoustic source in the shaft of a porcine femur. Ultrasonic signals were detected by a piezoelectric transducer, scanning along the long axis of the bone, 20-50 mm away from the source. Five femurs were measured without and with a soft …

research product

Association between low-frequency ultrasound and hip fractures - comparison with DXA-based BMD

Background: New methods for diagnosing osteoporosis and evaluating fracture risk are being developed. We aim to study the association between low-frequency (LF) axial transmission ultrasound and hip fracture risk in a population-based sample of older women. Methods: The study population consisted of 490 community-dwelling women (78 – 82 years). Ultrasound velocity (V LF ) at mid-tibia was measured in 2006 using a low-frequency scanning axial transmission device. Bone mineral density (BMD) at proximal femur measured using dual-energy x-ray absorptiometry (DXA) was used as the reference method. The fracture history of the participants was collected from December 1997 until the end of 2010. Li…

research product

103 Tibial Guided Wave Ultrasound in the Assessment of Osteoporosis in Elderly Women