0000000000191549

AUTHOR

Silvia Rodriguez

Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning

Purpose: According to the GYN GEC-ESTRO Recommendations, MRI is needed with the modality of T2 weighted. CT-MR compatible tandem Plus colpostats (T/C) (Nucletron) is widely used in cervical brachytherapy. The major challenge of MRI is the lack of dummy catheters. Therefore, an additional imaging modality is usually required. One disadvantage of sliced-based reconstruction is that resolution in longitudinal directions can be affected by the slice thickness. The aim of this study is to present a modified T/C applicator in which the catheter visibility is significantly improved. Methods and materials: A modification to the existing T/C applicator has been made available, increasing the cathete…

research product

The necessity of systematic verification of applicator position in brachytherapy treatment of the vaginal cuff

research product

Prescription Depth in Surface Skin Brachytherapy

research product

Urethral Dose Limit in Boost Permanent Prostate 125I Seed Implants Based on Biologically Effective Dose Values

research product

Dose Escalation in Permanent Brachytherapy for Prostate Cancer: Preliminary Results

research product

Efficacy and Safety of Degludec versus Glargine in Type 2 Diabetes.

BACKGROUND Degludec is an ultralong-Acting, once-daily basal insulin that is approved for use in adults, adolescents, and children with diabetes. Previous open-label studies have shown lower day-To-day variability in the glucose-lowering effect and lower rates of hypoglycemia among patients who received degludec than among those who received basal insulin glargine. However, data are lacking on the cardiovascular safety of degludec. METHODS We randomly assigned 7637 patients with type 2 diabetes to receive either insulin degludec (3818 patients) or insulin glargine U100 (3819 patients) once daily between dinner and bedtime in a double-blind, treat-To-Target, event-driven cardiovascular outco…

research product

MRI based treatment planning in gynaecological brachytherapy

research product

Interobserver study of countouringbased on ultrasound image in real-time interactive prostate brachytherapy

research product

The use of nomograms in LDR-HDR prostate brachytherapy

Purpose: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapt ed to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. Material and methods: Patients treated throughout 2010 till April 2011 were considered for this study. This exam ple was chosen to be the representative of the latest implant tech…

research product

A practical MRI-based reconstruction method for a new endocavitary and interstitial gynaecological template

Purpose: There are perineal templates for interstitial implants such as MUPIT and Syed applicators. Their limitations are the intracavitary component deficit and the necessity to use computed tomography (CT) for treatment planning since both applicators are non-magnetic resonance imaging (MRI) compatibles. To overcome these problems, a new template named Template Benidorm (TB) has been recently developed. Titanium needles are usually reconstructed based on their own artifacts, mainly in T1-weighted sequence, using the void on the tip as the needle tip position. Nevertheless, patient tissues surrounding the needles present heterogeneities that complicate the accurate identification of these …

research product

QA of dynamic MLC based on EPID portal dosimetry.

Abstract Purpose Dynamic delivery of intensity modulated beams (dIMRT) requires not only accurate verification of leaf positioning but also a control on the speed of motion. The latter is a parameter that has a major impact on the dose delivered to the patient. Time consumed in quality assurance (QA) procedures is an issue of relevance in any radiotherapy department. Electronic portal imaging dosimetry (EPID) can be very efficient for routine tests. The purpose of this work is to investigate the ability of our EPID for detecting small errors in leaf positioning, and to present our daily QA procedures for dIMRT based on EPID. Methods and materials A Varian 2100 CD Clinac equipped with an 80 …

research product

Semisynthetic roxburghin tetramethyl ether

The title molecule, (E)-2,3′,4,5-tetramethoxystilbene, C18H20O4, is virtually planar. The angle between the two benzene rings is 4.06 (6)°. The intermolecular interactions present in the structure are weak. There are C—H...O hydrogen bonds and C—H...π-electron ring interactions. The molecules are ordered into planes that are parallel to (overline{1}01). The distance between adjacent planes is about 3.3 Å and therefore π–π electron interactions between the aromatic planes are also plausible.

research product