New Forceps and Spatula for Easy Retropupillary Implantation of Iris Claw Lenses in Aphakia: Experience in 4 Years of Use

2008

PURPOSE. Retropupillary implantation of an iris claw lens offers a rapid and atraumatic approach for rehabilitation of aphakic eyes. The difficulty in the implantation process arises because of the possibility of losing the intraocular lens (IOL) into the vitreous cavity and the need to change the hand holding the forceps during the enclavation. M ETHODS. The new forceps design radically changes the method of grasping an IOL. It contains an extendable supporting plate with a hook-like end. The instrument achieves a horizontal three-point fixation at the edge of the implant in the 6 and 12 o’clock position in order to prevent slippage into the vitreous cavity during the inclination. The supp…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentForcepsIrisIntraocular lensAphakia PostcataractAphakiaVitreous cavitylaw.inventionFixation (surgical)Lens Implantation IntraocularlawOphthalmologymedicineHumansIris clawLenses IntraocularPhacoemulsificationbusiness.industryEquipment DesignGeneral Medicinemedicine.diseaseCentrationeye diseasesSurgeryLens (optics)Ophthalmologysense organsbusinessEuropean Journal of Ophthalmology
researchProduct

Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.

2007

Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…

Adultmedicine.medical_specialtyPhakic Intraocular LensesMaterials scienceBiometrymedicine.medical_treatmentIrisIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinemedicineMyopiaHumansIris clawOptical path lengthbusiness.industryHigh myopiaAccommodation OcularAstigmatismGeneral MedicineMiddle AgedOphthalmologymedicine.anatomical_structureLens (anatomy)030221 ophthalmology & optometrybusinessAccommodation030217 neurology & neurosurgeryTomography Optical CoherenceCoherence (physics)Follow-Up StudiesEuropean journal of ophthalmology