0000000000237562

AUTHOR

Giovanni Badalamenti

showing 3 related works from this author

Cinical outcomes of Endurant II stent-graft for infrarenal aortic aneurysm repair: comparison of on-label versus off-label use.

2016

Purpose We aimed to compare the outcomes of the Endurant II (Medtronic) stent-graft used under instructions for use versus off-label in high-risk patients considered unfit for conventional surgery. Methods Data from patients treated with the Endurant II stent-graft between December 2012 and March 2015 were retrospectively analyzed. Sixty-four patients were included. Patients were assigned to group A if treated under instructions for use (n=34, 53%) and to group B if treated off-label (n=30, 47%). Outcome measures included perioperative mortality and morbidity, survival, freedom from reintervention, endoleak incidence, in-hospital length of stay, and mean stent-graft component used. Mean fol…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignSettore MED/22 - Chirurgia VascolareRisk AssessmentGroup B03 medical and health sciencesAortic aneurysm0302 clinical medicinePostoperative ComplicationsOcclusionInterventional RadiologyMedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineSurvival analysisAgedAged 80 and overbusiness.industryRadiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular MedicineEndovascular ProceduresStentPerioperativeOff-Label UseMiddle Agedmedicine.diseaseSurvival AnalysisSurgeryBlood Vessel ProsthesisTreatment OutcomeFemaleStentsCardiology and Cardiovascular MedicinebusinessComplicationAbdominal surgeryAortic Aneurysm AbdominalDiagnostic and interventional radiology (Ankara, Turkey)
researchProduct

Symptomatic Deep Femoral Artery Pseudoaneurysm Endovascular Exclusion. Case Report and Literature Review.

2017

Deep femoral artery pseudoaneurysms (DFAPs) are rare and generally occur after penetrating trauma or surgical procedures. A 36-year-old obese man presented with pain in correspondence of the anterior-lateral thigh after 6 months from gunshot wound. Duplex and computed tomography (CT) showed a bilobed right DFAP (maximal diameter 12.9 cm). The patient was managed urgently, under local anesthesia, by placement in the distal DFA of a Viabahn 8 × 100-mm stent graft (W L Gore & Associates, Inc). The postoperative course was uneventful, and the 24-month CT showed regular stent-graft patency and 20-mm DFAP shrinkage. The literature review reported 8 cases of DFAPs; of these 6 were managed by endo…

AdultMalemedicine.medical_specialtyComputed Tomography Angiographymedicine.medical_treatment030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolare030218 nuclear medicine & medical imaging03 medical and health sciencesPseudoaneurysmBlood Vessel Prosthesis Implantation0302 clinical medicineAneurysmBlood vessel prosthesisDeep Femoral ArteryMedicineVascular PatencyHumansVascular PatencyUltrasonography Doppler Duplexbusiness.industryEndovascular ProceduresStentGeneral Medicinemedicine.diseaseSurgeryBlood Vessel ProsthesisFemoral Arterysurgical procedures operativeTreatment OutcomeRegional Blood FlowSurgeryStentsWounds GunshotRadiologyGunshot woundbusinessCardiology and Cardiovascular MedicinePenetrating traumaAneurysm FalseAnnals of vascular surgery
researchProduct

Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair

2019

Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…

MaleTime Factorsmedicine.medical_treatmentContrast MediaPredictive Value of TestEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysmRetrospective StudieRisk FactorsIntravascular ultrasoundFluoroscopyAged 80 and overmedicine.diagnostic_testEndovascular ProceduresGeneral MedicineMiddle AgedRadiation ExposureAbdominal aortic aneurysm2746 SurgeryTreatment OutcomeItalyFemaleRadiologyCardiology and Cardiovascular Medicinerenal function impairmentHumanPreliminary Datamedicine.medical_specialtyTime Factor610 Medicine & healthRadiation DosageAortography2705 Cardiology and Cardiovascular Medicineintravascular ultrasoundBlood Vessel Prosthesis ImplantationEndovascular aneurysm repaircontrast mediumPredictive Value of Testsmedicinefluoroscopy timeHumansUltrasonography InterventionalAgedRetrospective StudiesEndovascular Procedurebusiness.industryRisk FactorAngiography Digital SubtractionPerioperativeDigital subtraction angiographymedicine.disease10020 Clinic for Cardiac SurgeryAngiographySurgerybusinessAortic Aneurysm Abdominal
researchProduct