First measurement of the rate K0L → πμνγ

Abstract In a preliminary version of the NA48 experiment at the CERN SPS, in which an iron-scintillator sandwich calorimeter was used as a photon detector, the ratio of K L → πμνγ and K L → πμν decays was measured. The branching ratio BR(K L →πμνγ, E γ ∗ ≥30 MeV )/(K L → πμν ) is found to be (2.08±0.17 +0.16 −0.21 )×10 −3 , where the first error is statistical and the second systematic. The result is in agreement with theoretical predictions.

research product

SPI/INTEGRAL in-flight performance

The SPI instrument has been launched on-board the INTEGRAL observatory on October 17, 2002. SPI is a spectrometer devoted to the sky observation in the 20 keV-8 MeV energy range using 19 germanium detectors. The performance of the cryogenic system is nominal and allows to cool the 19 kg of germanium down to 85 K with a comfortable margin. The energy resolution of the whole camera is 2.5 keV at 1.1 MeV. This resolution degrades with time due to particle irradiation in space. We show that the annealing process allows the recovery of the initial performance. The anticoincidence shield works as expected, with a low threshold at 75 keV, reducing the GeD background by a factor of 20. The digital …

research product

The INTEGRAL/SPI response and the Crab observations

The Crab region was observed several times by INTEGRAL for calibration purposes. This paper aims at underlining the systematic interactions between (i) observations of this reference source, (ii) in-flight calibration of the instrumental response and (iii) the development and validation of the analysis tools of the SPI spectrometer. It first describes the way the response is produced and how studies of the Crab spectrum lead to improvements and corrections in the initial response. Then, we present the tools which were developed to extract spectra from the SPI observation data and finally a Crab spectrum obtained with one of these methods, to show the agreement with previous experiments. We …

research product

SPI/INTEGRAL observation of the Cygnus region

We present the analysis of the first observations of the Cygnus region by the SPI spectrometer onboard the Integral Gamma Ray Observatory, encompassing ${\sim}$ 600 ks of data. Three sources namely Cyg X-1, Cyg X-3 and EXO 2030+375 were clearly detected. Our data illustrate the temporal variability of Cyg X-1 in the energy range from 20 keV to 300 keV. The spectral analysis shows a remarkable stability of the Cyg X-1 spectra when averaged over one day timescale. The other goal of these observations is SPI inflight calibration and performance verification. The latest objective has been achieved as demonstrated by the results presented in this paper.

research product

INTEGRAL/SPI ground calibration

Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.

research product

Measurement of the decay rate and form factor parameter in the decay KL→e+e−γ

Abstract The decay rate of the neutral K meson KL→e+e−γ has been measured with the NA48 detector at the CERN SPS. A total of 6864 events has been observed with an estimated background of 10 events. The branching ratio is Γ(KL→e+e−γ)/Γ(KL→all) = (1.06±0.02stat±0.02sys±0.04calc)×10−5. The parameter α K ∗ describing the relative strength of the two contributing amplitudes to this decay through intermediate pseudoscalar or vector mesons was measured to be α K ∗ =−0.36±0.06stat±0.02sys.