0000000000249294

AUTHOR

Chiarasole Fiamozzi Zignani

Design optimization for the quench protection of DTT's superconducting toroidal field magnets

Abstract The paper is focused on the optimal design of Fast Discharge Unit (FDU) for the quench protection of the Toroidal Field (TF) magnets of the Divertor Tokamak Test facility (DTT), an experimental facility under construction in ENEA Frascati Research Centre (Rome, Italy). The FDU is a safety key component that protects the superconducting magnets when a quench is detected through the fast extraction of the energy stored in the magnets by adding a discharge dump resistor (DR) in the TF magnets circuit. A comparison between a fixed DR and a switched variable DR has been implemented by changing resistor parameters and by using multiple current control of the power electronics components …

research product

Conceptual Design and Modeling of the Toroidal Field Coils Circuit of DTT

Italian Divertor Tokamak Test (DTT) facility is part of the general European programme on the fusion research. Its specific role is to cover the gap on the power exhaust for the future DEMOstration power plant (DEMO). This tokamak will be built and installed in Italy at Frascati ENEA laboratories. The paper describes the Toroidal Field (TF) coils circuit powered by a TF power supply that feeds in series 18 toroidal superconducting magnets and the development of three software models in order to validate the adopted technical solutions in term of maximum voltage and maximum current stress on each power device/component, due to both the operating and fault conditions, and across TF coils.

research product

Transient Electrical Behaviour of the TF Superconducting Coils of Divertor Tokamak Test Facility During a Fast Discharge

The paper is focused on the electromagnetic analysis of the Toroidal Field (TF) superconducting coils of the Divertor Tokamak Test facility (DTT) when electrical transients occur in the TF coils system: for example, during the operations of the Fast Discharge Units (FDUs) and considering also, the simultaneous occurrence of a fault condition. During the FDU intervention, a transient voltage excitation lasting few microseconds occurs at the TF coil terminals and it electrically stresses the insulations of TF coils itsef. To investigate the voltage distribution across, inside and between different Double Pancakes (DPs) of each TF coil, a lumped parameters circuital model has been developed an…

research product